5,600 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
50.00 kW
50.00 kW
Entrada EI
10.64 kW
15.15 kW
COP
4.70
3.30
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
80 dB(A)
80 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
247.70 %
189.30 %
Prated
50.0 kW
50.0 kW
SCOP
6.27
4.81
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
50.00 kW
48.86 kW
COP Tj = +2°C
3.42
2.60
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
32.41 kW
31.46 kW
COP Tj = +7°C
5.81
4.30
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
14.02 kW
14.04 kW
COP Tj = 12°C
8.05
6.36
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
32.41 kW
31.46 kW
COP Tj = Tbiv
5.81
4.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
50.00 kW
48.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.42
2.60
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
1.14 kW
Consumo annual de energia QHE
10659.00 kWh
13898.00 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
80 dB(A)
80 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
155 %
138 %
Prated
50.0 kW
50.0 kW
SCOP
3.68
3.28
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
30.10 kW
30.33 kW
COP Tj = -7°C
3.45
2.85
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
17.98 kW
19.73 kW
COP Tj = +2°C
4.53
4.20
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
12.04 kW
12.35 kW
COP Tj = +7°C
6.63
5.69
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
7.83 kW
12.13 kW
COP Tj = 12°C
7.32
5.69
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
42.15 kW
40.33 kW
COP Tj = Tbiv
2.34
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
43.90 kW
50.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.79
1.60
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
6.10 kW
0.00 kW
Consumo annual de energia QHE
31231.00 kWh
35048.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
42.15
40.33
COP Tj = -15°C (if TOL<-20°C)
2.34
2.18
Cdh Tj = -15 °C
0.90
0.90
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
80 dB(A)
80 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
185 %
153 %
Prated
50.0 kW
50.0 kW
SCOP
4.70
3.90
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
45.18 kW
44.14 kW
COP Tj = -7°C
2.80
2.40
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
28.40 kW
28.61 kW
COP Tj = +2°C
4.49
3.86
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
17.57 kW
17.21 kW
COP Tj = +7°C
6.58
5.21
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
7.83 kW
12.09 kW
COP Tj = 12°C
7.59
6.24
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
45.18 kW
44.14 kW
COP Tj = Tbiv
2.80
2.40
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
50.39 kW
51.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
2.12
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
22051 kWh
26324 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
60.00 kW
60.00 kW
Entrada EI
13.95 kW
19.61 kW
COP
4.30
3.06
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
84.4 dB(A)
84.4 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
248.70 %
187.20 %
Prated
60.0 kW
60.0 kW
SCOP
6.29
4.75
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
59.13 kW
57.59 kW
COP Tj = +2°C
3.05
2.39
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
38.39 kW
37.72 kW
COP Tj = +7°C
5.67
4.20
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
18.37 kW
17.74 kW
COP Tj = 12°C
8.47
6.44
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
38.39 kW
37.72 kW
COP Tj = Tbiv
5.67
4.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
59.13 kW
57.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
2.39
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.87 kW
2.41 kW
Consumo annual de energia QHE
12741.00 kWh
16860.00 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
84.4 dB(A)
84.4 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
145 %
129 %
Prated
60.0 kW
60.0 kW
SCOP
3.69
3.29
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
39.69 kW
39.97 kW
COP Tj = -7°C
3.01
2.74
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
22.96 kW
24.38 kW
COP Tj = +2°C
4.45
3.89
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
14.53 kW
14.90 kW
COP Tj = +7°C
6.46
5.48
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
7.72 kW
12.15 kW
COP Tj = 12°C
7.45
5.48
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
52.33 kW
50.64 kW
COP Tj = Tbiv
2.10
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
43.90 kW
50.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.79
1.60
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
16.10 kW
9.46 kW
Consumo annual de energia QHE
40105.00 kWh
44978.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
52.33
50.64
COP Tj = -15°C (if TOL<-20°C)
2.10
2.04
Cdh Tj = -15 °C
0.90
0.90
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
84.4 dB(A)
84.4 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
181 %
151 %
Prated
60.0 kW
60.0 kW
SCOP
4.60
3.86
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
52.46 kW
51.15 kW
COP Tj = -7°C
2.61
2.21
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
32.53 kW
32.14 kW
COP Tj = +2°C
4.39
3.73
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
21.65 kW
21.58 kW
COP Tj = +7°C
6.59
5.36
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
9.79 kW
11.86 kW
COP Tj = 12°C
8.66
6.89
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
52.46 kW
51.15 kW
COP Tj = Tbiv
2.61
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
59.61 kW
59.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
2.01
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.39 kW
0.05 kW
Consumo annual de energia QHE
26927 kWh
32176 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
70.00 kW
70.00 kW
Entrada EI
17.50 kW
23.73 kW
COP
4.00
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
86.7 dB(A)
86.7 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
243.20 %
187.20 %
Prated
65.0 kW
65.0 kW
SCOP
6.15
4.75
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
63.03 kW
63.70 kW
COP Tj = +2°C
2.89
2.38
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
41.36 kW
41.07 kW
COP Tj = +7°C
5.50
4.13
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
18.37 kW
17.74 kW
COP Tj = 12°C
8.47
6.44
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
41.36 kW
41.07 kW
COP Tj = Tbiv
5.50
4.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
63.03 kW
63.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.89
2.38
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.97 kW
1.30 kW
Consumo annual de energia QHE
14110.00 kWh
18264.00 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
86.7 dB(A)
86.7 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
144 %
128 %
Prated
64.0 kW
64.0 kW
SCOP
3.95
3.52
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
39.69 kW
39.97 kW
COP Tj = -7°C
3.01
2.74
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
22.96 kW
24.38 kW
COP Tj = +2°C
4.45
3.80
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
14.53 kW
14.90 kW
COP Tj = +7°C
6.46
5.48
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
7.72 kW
12.15 kW
COP Tj = 12°C
7.43
5.45
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
52.33 kW
50.64 kW
COP Tj = Tbiv
2.10
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
43.90 kW
50.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.79
1.60
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
20.10 kW
13.46 kW
Consumo annual de energia QHE
42832.00 kWh
48107.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
52.33
50.64
COP Tj = -15°C (if TOL<-20°C)
2.10
2.04
Cdh Tj = -15 °C
0.90
0.90
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
86.7 dB(A)
86.7 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
177 %
147 %
Prated
65.0 kW
65.0 kW
SCOP
4.50
3.76
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
57.34 kW
57.95 kW
COP Tj = -7°C
2.48
2.13
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
34.71 kW
35.42 kW
COP Tj = +2°C
4.31
3.61
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
21.65 kW
21.58 kW
COP Tj = +7°C
6.59
5.36
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
9.79 kW
11.86 kW
COP Tj = 12°C
8.66
6.89
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
57.34 kW
57.95 kW
COP Tj = Tbiv
2.48
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
59.61 kW
64.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.95
WTOL
85.00 °C
85.00 °C
Poff
0.14 W
0.14 W
PTO
0.62 W
0.62 W
PSB
0.14 W
0.14 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
5.39 kW
0.54 kW
Consumo annual de energia QHE
29758 kWh
35694 kWh