Certificate holders

Subtype

TTF 66

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0282
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTF 66
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

14,500 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 1

Models

TTF 66
Configure model
Model name
TTF 66
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

67.10 kW

62.30 kW

El input

14.23 kW

21.60 kW

COP

4.56

2.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

130 %

Prated

67.00 kW

62.00 kW

SCOP

4.95

3.45

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

67.10 kW

62.30 kW

COP Tj = +2°C

4.56

2.82

Pdh Tj = +7°C

67.60 kW

63.70 kW

COP Tj = +7°C

4.86

3.20

Pdh Tj = 12°C

68.40 kW

65.90 kW

COP Tj = 12°C

5.37

3.96

Pdh Tj = Tbiv

67.10 kW

62.30 kW

COP Tj = Tbiv

4.56

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

67.10 kW

62.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

99 W

99 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

18119 kWh

24059 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

136 %

Prated

83.00 kW

78.00 kW

SCOP

5.13

3.60

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

68.00 kW

64.40 kW

COP Tj = -7°C

5.09

3.42

Pdh Tj = +2°C

68.30 kW

65.50 kW

COP Tj = +2°C

5.34

3.81

Pdh Tj = +7°C

68.60 kW

66.30 kW

COP Tj = +7°C

5.55

4.18

Pdh Tj = 12°C

68.70 kW

67.00 kW

COP Tj = 12°C

5.58

4.49

Pdh Tj = Tbiv

67.80 kW

63.70 kW

COP Tj = Tbiv

4.99

3.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

67.10 kW

62.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

99 W

99 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

16.03 kW

15.83 kW

Annual energy consumption Qhe

39996 kWh

53447 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

59 dB(A)

59 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

131 %

Prated

67.00 kW

62.00 kW

SCOP

4.95

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

67.20 kW

62.80 kW

COP Tj = -7°C

4.62

2.94

Pdh Tj = +2°C

67.20 kW

62.80 kW

COP Tj = +2°C

4.93

3.44

Pdh Tj = +7°C

68.20 kW

65.50 kW

COP Tj = +7°C

5.25

3.82

Pdh Tj = 12°C

68.70 kW

66.50 kW

COP Tj = 12°C

5.61

4.28

Pdh Tj = Tbiv

67.10 kW

62.30 kW

COP Tj = Tbiv

4.56

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

67.10 kW

62.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

99 W

99 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

28022 kWh

37120 kWh