Certificate holders

Subtype

TTF 40

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0281
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTF 40
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

10,000 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 1

Models

TTF 40
Configure model
Model name
TTF 40
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

43.10 kW

40.20 kW

El input

9.23 kW

17.45 kW

COP

4.67

2.99

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

133 %

Prated

43.00 kW

40.00 kW

SCOP

5.05

3.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

43.10 kW

40.20 kW

COP Tj = +2°C

4.67

2.88

Pdh Tj = +7°C

43.40 kW

41.10 kW

COP Tj = +7°C

4.98

3.27

Pdh Tj = 12°C

43.90 kW

42.40 kW

COP Tj = 12°C

5.51

4.05

Pdh Tj = Tbiv

43.10 kW

40.20 kW

COP Tj = Tbiv

4.67

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

43.10 kW

40.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

74 W

74 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

11415 kWh

15248 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

139 %

Prated

53.00 kW

50.00 kW

SCOP

5.25

3.68

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

43.60 kW

41.50 kW

COP Tj = -7°C

5.22

3.49

Pdh Tj = +2°C

43.90 kW

42.10 kW

COP Tj = +2°C

5.48

3.90

Pdh Tj = +7°C

44.00 kW

42.60 kW

COP Tj = +7°C

5.70

4.28

Pdh Tj = 12°C

44.00 kW

41.10 kW

COP Tj = 12°C

5.11

3.27

Pdh Tj = Tbiv

43.10 kW

41.10 kW

COP Tj = Tbiv

5.11

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

43.10 kW

40.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

74 W

74 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.27 kW

10.14 kW

Annual energy consumption Qhe

25071 kWh

33723 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

133 %

Prated

43.00 kW

40.00 kW

SCOP

5.05

3.53

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

43.20 kW

40.50 kW

COP Tj = -7°C

4.73

3.00

Pdh Tj = +2°C

43.50 kW

41.50 kW

COP Tj = +2°C

5.05

3.51

Pdh Tj = +7°C

43.80 kW

42.10 kW

COP Tj = +7°C

5.38

3.90

Pdh Tj = 12°C

44.10 kW

42.80 kW

COP Tj = 12°C

5.76

4.38

Pdh Tj = Tbiv

43.10 kW

40.20 kW

COP Tj = Tbiv

4.67

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

43.10 kW

40.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

74 W

74 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

17606 kWh

23479 kWh