7,200 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
29.69 kW
26.69 kW
El input
6.12 kW
9.57 kW
COP
4.85
2.79
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
55 dB(A)
55 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
131 %
Prated
30.00 kW
27.00 kW
SCOP
5.23
3.48
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
29.70 kW
26.70 kW
COP Tj = +2°C
4.85
2.79
Pdh Tj = +7°C
30.00 kW
27.60 kW
COP Tj = +7°C
5.22
3.22
Pdh Tj = 12°C
30.50 kW
28.90 kW
COP Tj = 12°C
5.85
4.10
Pdh Tj = Tbiv
29.70 kW
26.70 kW
COP Tj = Tbiv
4.85
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
29.70 kW
26.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.85
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
74 W
74 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
7587 kWh
10292 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
55 dB(A)
55 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
213 %
139 %
Prated
37.00 kW
34.00 kW
SCOP
5.53
3.68
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
30.20 kW
28.00 kW
COP Tj = -7°C
5.51
3.47
Pdh Tj = +2°C
30.50 kW
28.70 kW
COP Tj = +2°C
5.83
3.92
Pdh Tj = +7°C
30.60 kW
29.20 kW
COP Tj = +7°C
6.09
4.36
Pdh Tj = 12°C
30.70 kW
29.60 kW
COP Tj = 12°C
6.13
4.73
Pdh Tj = Tbiv
30.10 kW
27.60 kW
COP Tj = Tbiv
5.38
3.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
29.70 kW
26.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.85
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
74 W
74 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.26 kW
7.13 kW
Annual energy consumption Qhe
1646 kWh
22680 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
55 dB(A)
55 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
132 %
Prated
30.00 kW
27.00 kW
SCOP
5.28
3.50
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
29.80 kW
27.00 kW
COP Tj = -7°C
4.92
2.92
Pdh Tj = +2°C
30.10 kW
28.00 kW
COP Tj = +2°C
5.31
3.49
Pdh Tj = +7°C
30.40 kW
28.70 kW
COP Tj = +7°C
5.71
3.93
Pdh Tj = 12°C
30.70 kW
29.30 kW
COP Tj = 12°C
6.16
4.47
Pdh Tj = Tbiv
29.70 kW
26.70 kW
COP Tj = Tbiv
4.85
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
29.70 kW
26.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.85
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
74 W
74 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
11619 kWh
15758 kWh