1,100 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
4.50 kW
El input
1.41 kW
1.79 kW
COP
4.26
2.51
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
115 %
Prated
5.20 kW
4.50 kW
SCOP
4.30
2.95
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.00 kW
COP Tj = -7°C
2.70
1.80
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.80 kW
2.50 kW
COP Tj = +2°C
4.20
2.90
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.30 kW
1.70 kW
COP Tj = +7°C
6.00
4.00
Cdh Tj = +7 °C
Pdh Tj = 12°C
2.30 kW
2.10 kW
COP Tj = 12°C
8.30
5.80
Cdh Tj = +12 °C
Pdh Tj = Tbiv
4.60 kW
4.00 kW
COP Tj = Tbiv
2.70
1.80
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
3.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
55 °C
55 °C
Poff
6 W
6 W
PTO
23 W
16 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.70 kW
1.00 kW
Annual energy consumption Qhe
2505 kWh
3180 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
120 %
COP
3.00
Heating up time
01:45 h:min
Standby power input
32.0 W
Reference hot water temperature
54.0 °C
Mixed water at 40°C
249 l