Certificate holders

Subtype

Mega L

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-SC0834-18 / Issue 3
Certification Body
RISE CERT
Subtype title
Mega L
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

6,300 kg

Certification Date
10.04.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Thermia Mega L 2020
Configure model
Model name
Thermia Mega L 2020
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

34.97 kW

31.56 kW

El input

7.76 kW

11.04 kW

COP

4.51

2.86

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

59.64 kW

55.34 kW

SCOP

5.28

4.13

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

59.64 kW

55.34 kW

COP Tj = +2°C

3.93

2.77

Pdh Tj = +7°C

38.34 kW

35.58 kW

COP Tj = +7°C

5.00

3.69

Pdh Tj = 12°C

17.04 kW

15.81 kW

COP Tj = 12°C

5.79

4.85

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

15055 kWh

17857 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

160 %

Prated

59.64 kW

55.34 kW

SCOP

5.29

4.20

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

35.77 kW

33.80 kW

COP Tj = -7°C

5.14

3.85

Pdh Tj = +2°C

21.97 kW

20.39 kW

COP Tj = +2°C

5.71

4.59

Pdh Tj = +7°C

16.74 kW

16.35 kW

COP Tj = +7°C

5.86

4.85

Pdh Tj = 12°C

16.58 kW

16.38 kW

COP Tj = 12°C

5.58

4.88

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

27759 kWh

32491 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

155 %

Prated

59.64 kW

55.34 kW

SCOP

5.19

4.07

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

52.76 kW

48.96 kW

COP Tj = -7°C

4.26

3.01

Pdh Tj = +2°C

32.11 kW

29.80 kW

COP Tj = +2°C

5.23

4.11

Pdh Tj = +7°C

20.64 kW

19.16 kW

COP Tj = +7°C

5.74

4.84

Pdh Tj = 12°C

16.56 kW

16.33 kW

COP Tj = 12°C

5.58

4.66

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

23714 kWh

28063 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

48.57 kW

43.13 kW

El input

8.51 kW

11.59 kW

COP

5.71

3.72

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

265 %

207 %

Prated

51.32 kW

53.23 kW

SCOP

6.83

5.38

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

51.32 kW

53.23 kW

COP Tj = +2°C

5.35

3.65

Pdh Tj = +7°C

32.99 kW

34.22 kW

COP Tj = +7°C

6.59

4.90

Pdh Tj = 12°C

21.67 kW

21.11 kW

COP Tj = 12°C

7.37

6.21

Pdh Tj = Tbiv

51.32 kW

53.23 kW

COP Tj = Tbiv

5.35

3.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

51.32 kW

53.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.35

3.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

10032 kWh

13221 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

272 %

215 %

Prated

51.32 kW

53.23 kW

SCOP

6.99

5.57

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

31.06 kW

32.22 kW

COP Tj = -7°C

6.78

5.15

Pdh Tj = +2°C

21.66 kW

19.61 kW

COP Tj = +2°C

7.37

6.08

Pdh Tj = +7°C

21.70 kW

21.22 kW

COP Tj = +7°C

7.45

6.37

Pdh Tj = 12°C

21.65 kW

21.36 kW

COP Tj = 12°C

7.34

6.60

Pdh Tj = Tbiv

51.32 kW

53.23 kW

COP Tj = Tbiv

5.35

3.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

51.32 kW

53.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.35

3.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

18086 kWh

23548 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

264 %

206 %

Prated

51.32 kW

53.23 kW

SCOP

6.80

5.35

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

45.39 kW

47.08 kW

COP Tj = -7°C

5.63

3.98

Pdh Tj = +2°C

27.63 kW

28.66 kW

COP Tj = +2°C

6.92

5.43

Pdh Tj = +7°C

21.64 kW

21.02 kW

COP Tj = +7°C

7.32

6.08

Pdh Tj = 12°C

21.70 kW

21.25 kW

COP Tj = 12°C

7.45

6.43

Pdh Tj = Tbiv

51.32 kW

53.23 kW

COP Tj = Tbiv

5.35

3.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

51.32 kW

53.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.35

3.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

15600 kWh

20546 kWh

Thermia Mega L
Configure model
Model name
Thermia Mega L
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

34.97 kW

31.56 kW

El input

7.76 kW

11.04 kW

COP

4.51

2.86

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

59.64 kW

55.34 kW

SCOP

5.28

4.13

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

59.64 kW

55.34 kW

COP Tj = +2°C

3.93

2.77

Pdh Tj = +7°C

38.34 kW

35.58 kW

COP Tj = +7°C

5.00

3.69

Pdh Tj = 12°C

17.04 kW

15.81 kW

COP Tj = 12°C

5.79

4.85

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

15055 kWh

17857 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

160 %

Prated

59.64 kW

55.34 kW

SCOP

5.29

4.20

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

35.77 kW

33.80 kW

COP Tj = -7°C

5.14

3.85

Pdh Tj = +2°C

21.97 kW

20.39 kW

COP Tj = +2°C

5.71

4.59

Pdh Tj = +7°C

16.74 kW

16.35 kW

COP Tj = +7°C

5.86

4.85

Pdh Tj = 12°C

16.58 kW

16.38 kW

COP Tj = 12°C

5.58

4.88

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

27759 kWh

32491 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

155 %

Prated

59.64 kW

55.34 kW

SCOP

5.19

4.07

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

52.76 kW

48.96 kW

COP Tj = -7°C

4.26

3.01

Pdh Tj = +2°C

32.11 kW

29.80 kW

COP Tj = +2°C

5.23

4.11

Pdh Tj = +7°C

20.64 kW

19.16 kW

COP Tj = +7°C

5.74

4.84

Pdh Tj = 12°C

16.56 kW

16.33 kW

COP Tj = 12°C

5.58

4.66

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

23714 kWh

28063 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

48.57 kW

43.13 kW

El input

8.51 kW

11.59 kW

COP

5.71

3.72

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

265 %

207 %

Prated

51.32 kW

53.23 kW

SCOP

6.83

5.38

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

51.32 kW

53.23 kW

COP Tj = +2°C

5.35

3.65

Pdh Tj = +7°C

32.99 kW

34.22 kW

COP Tj = +7°C

6.59

4.90

Pdh Tj = 12°C

21.67 kW

21.11 kW

COP Tj = 12°C

7.37

6.21

Pdh Tj = Tbiv

51.32 kW

53.23 kW

COP Tj = Tbiv

5.35

3.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

51.32 kW

53.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.35

3.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

10032 kWh

13221 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

272 %

215 %

Prated

51.32 kW

53.23 kW

SCOP

6.99

5.57

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

31.06 kW

32.22 kW

COP Tj = -7°C

6.78

5.15

Pdh Tj = +2°C

21.66 kW

19.61 kW

COP Tj = +2°C

7.37

6.08

Pdh Tj = +7°C

21.70 kW

21.22 kW

COP Tj = +7°C

7.45

6.37

Pdh Tj = 12°C

21.65 kW

21.36 kW

COP Tj = 12°C

7.34

6.60

Pdh Tj = Tbiv

51.32 kW

53.23 kW

COP Tj = Tbiv

5.35

3.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

51.32 kW

53.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.35

3.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

18086 kWh

23548 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

264 %

206 %

Prated

51.32 kW

53.23 kW

SCOP

6.80

5.35

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

45.39 kW

47.08 kW

COP Tj = -7°C

5.63

3.98

Pdh Tj = +2°C

27.63 kW

28.66 kW

COP Tj = +2°C

6.92

5.43

Pdh Tj = +7°C

21.64 kW

21.02 kW

COP Tj = +7°C

7.32

6.08

Pdh Tj = 12°C

21.70 kW

21.25 kW

COP Tj = 12°C

7.45

6.43

Pdh Tj = Tbiv

51.32 kW

53.23 kW

COP Tj = Tbiv

5.35

3.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

51.32 kW

53.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.35

3.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

15600 kWh

20546 kWh