1,840 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16 kW
16 kW
El input
3.54 kW
5.49 kW
COP
4.52
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
171 %
Prated
13.00 kW
14.00 kW
SCOP
6.05
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.00 kW
13.20 kW
COP Tj = +2°C
3.34
2.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.50 kW
9.00 kW
COP Tj = +7°C
5.20
3.69
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.80 kW
4.10 kW
COP Tj = 12°C
7.95
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.50 kW
9.00 kW
COP Tj = Tbiv
5.20
3.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
13.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.34
2.31
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2936 kWh
4331 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
155 %
121 %
Prated
14 kW
12 kW
SCOP
3.95
3.1
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.1 kW
7.7 kW
COP Tj = -7°C
3.3
2.61
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
5 kW
4.5 kW
COP Tj = +2°C
4.88
3.79
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
3.2 kW
3.1 kW
COP Tj = +7°C
5.75
4.87
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
3.7 kW
3.6 kW
COP Tj = 12°C
7.59
6.38
Cdh Tj = +12 °C
0.9
0.9
Pdh Tj = Tbiv
11.3 kW
9.6 kW
COP Tj = Tbiv
2.28
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.8 kW
5.1 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.2 kW
6.9 kW
Annual energy consumption Qhe
8667 kWh
9388 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.3
9.6
COP Tj = -15°C (if TOL<-20°C)
2.28
1.84
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
134 %
Prated
15 kW
13 kW
SCOP
4.55
3.43
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.5 kW
11.4 kW
COP Tj = -7°C
2.7
2.05
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
8 kW
7.1 kW
COP Tj = +2°C
4.39
3.33
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
5.4 kW
4.5 kW
COP Tj = +7°C
6.33
4.62
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
4.5 kW
3.4 kW
COP Tj = 12°C
8.57
6.12
Cdh Tj = +12 °C
0.9
0.9
Pdh Tj = Tbiv
13.5 kW
11.4 kW
COP Tj = Tbiv
2.7
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.2 kW
11.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.77
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.8 kW
1.8 kW
Annual energy consumption Qhe
6915 kWh
7765 kWh