DWW-A2-AE16LW-3P-R32+DWW-A2-HM16-HS9-3P-R32

Certificate Holder
Deutsche Wärmepumpen Werke GmbH
Am Obstgut 11,
04425 Taucha
Germany
Registration number
ICIM-PDC-000443
Certification Body
ICIM S.p.A.
Subtype title
DWW-A2-AE16LW-3P-R32+DWW-A2-HM16-HS9-3P-R32
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,840 kg

Certification Date
23.01.2025
Testing basis
V14
Testing laboratory
Intertek Testing Services Shenzhen LTD. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

DWW-A2-AE16LW-3P-R32 + DWW-A2-HM16-HS9-3P-R32
Configure model
Model name
DWW-A2-AE16LW-3P-R32 + DWW-A2-HM16-HS9-3P-R32
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.5 kW

15.5 kW

El input

3.36 kW

5.18 kW

COP

4.61

2.99

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256.2 %

170.9 %

Prated

14.1 kW

14.1 kW

SCOP

6.49

4.35

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.1 kW

14.07 kW

COP Tj = +2°C

3.28

2.23

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

8.91 kW

8.91 kW

COP Tj = +7°C

5.81

3.79

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.64 kW

5.14 kW

COP Tj = 12°C

8.14

5.55

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

14.1 kW

14.07 kW

COP Tj = Tbiv

3.28

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.1 kW

14.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.28

2.23

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Oil

Oil

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2907 kWh

4333 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179.1 %

130.9 %

Prated

15.5 kW

13 kW

SCOP

4.55

3.35

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.46 kW

8.04 kW

COP Tj = -7°C

3.78

2.91

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5.59 kW

4.82 kW

COP Tj = +2°C

5.62

3.99

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.46 kW

5.09 kW

COP Tj = +7°C

7.12

5.18

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.67 kW

6.08 kW

COP Tj = 12°C

7.35

6.68

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

12.61 kW

10.8 kW

COP Tj = Tbiv

2.74

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.64 kW

11.12 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.43

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

1.89 kW

Annual energy consumption Qhe

8393 kWh

9573 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.61

10.8

COP Tj = -15°C (if TOL<-20°C)

2.74

1.98

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

151 %

Prated

15.5 kW

15 kW

SCOP

4.93

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.68 kW

13.62 kW

COP Tj = -7°C

2.9

2.35

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

8.6 kW

8.24 kW

COP Tj = +2°C

4.67

3.7

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.65 kW

5.23 kW

COP Tj = +7°C

7

5.24

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

6 kW

5.84 kW

COP Tj = 12°C

8.91

6.65

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

13.68 kW

13.62 kW

COP Tj = Tbiv

2.9

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.5 kW

13.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.45

2.06

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Oil

Oil

Supplementary Heater: PSUP

0 kW

1.78 kW

Annual energy consumption Qhe

6504 kWh

8050 kWh