Certificate holders

Subtype

Buderus Logatherm WLW166i MBB-10/13 AR P3

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W1297
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus Logatherm WLW166i MBB-10/13 AR P3
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,365 kg

Certification Date
15.06.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland Energy GmbH, DE
Generate PDF Export model CSV
  • Number of models 12

Models

WLW166i-10 MBB AR P3 T180
Configure model
Model name
WLW166i-10 MBB AR P3 T180
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.1 kW

9.91 kW

El input

1.92 kW

3.29 kW

COP

4.73

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

179 %

Prated

10 kW

10 kW

SCOP

6.41

4.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.16 kW

9.67 kW

COP Tj = +2°C

3.54

2.55

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.18 kW

6.2 kW

COP Tj = +7°C

5.71

3.94

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

3.1 kW

2.95 kW

COP Tj = 12°C

7.81

5.68

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

10.16 kW

9.67 kW

COP Tj = Tbiv

3.54

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.2 kW

9.7 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.54

2.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2084 kWh

2932 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

136 %

Prated

10 kW

10 kW

SCOP

4.45

3.47

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.96 kW

6.06 kW

COP Tj = -7°C

3.77

2.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.26 kW

3.98 kW

COP Tj = +2°C

5.2

4.06

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.54 kW

3.36 kW

COP Tj = +7°C

6.67

5.14

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.07 kW

2.97 kW

COP Tj = 12°C

7.35

5.88

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

8.89 kW

8.46 kW

COP Tj = Tbiv

2.65

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.2 kW

6.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

3.2 kW

Annual energy consumption Qhe

5541 kWh

7105 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.46

8.02

COP Tj = -15°C (if TOL<-20°C)

2.84

2.23

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

154 %

Prated

10 kW

10 kW

SCOP

5.01

3.92

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.84 kW

8.80 kW

COP Tj = -7°C

3.10

2.50

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

5.68 kW

5.63 kW

COP Tj = +2°C

4.88

3.81

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

3.51 kW

3.46 kW

COP Tj = +7°C

6.62

5.05

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.12 kW

3.14 kW

COP Tj = 12°C

7.80

6.03

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

9.60 kW

9.31 kW

COP Tj = Tbiv

2.70

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.60 kW

9.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4123 kWh

5277 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

163 %

COP

4.08

Heating up time

2:13 h:min

Standby power input

32 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.5

Heating up time

2:02 h:min

Standby power input

83 W

Reference hot water temperature

51.5 °C

Mixed water at 40°C

255 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

143 %

COP

3.56

Heating up time

2:12 h:min

Standby power input

35 W

Reference hot water temperature

51.5 °C

Mixed water at 40°C

253 l

WLW166i-13 MBB AR P3 T180
Configure model
Model name
WLW166i-13 MBB AR P3 T180
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.05 kW

13.15 kW

El input

2.48 kW

5.04 kW

COP

4.46

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

186 %

Prated

12.50 kW

12.50 kW

SCOP

6.41

4.72

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.29 kW

12.57 kW

COP Tj = +2°C

2.86

2.24

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

7.94 kW

7.81 kW

COP Tj = +7°C

5.59

3.90

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.60 kW

3.93 kW

COP Tj = 12°C

8.27

6.34

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.29 kW

12.57 kW

COP Tj = Tbiv

2.86

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

12.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3541 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

134 %

Prated

12.5 kW

12.5 kW

SCOP

4.33

3.43

Tbiv

-14 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.35 kW

7.42 kW

COP Tj = -7°C

3.67

2.88

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.28 kW

4.66 kW

COP Tj = +2°C

5.21

4.11

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.56 kW

3.4 kW

COP Tj = +7°C

6.89

5.38

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.08 kW

2.99 kW

COP Tj = 12°C

7.5

6.04

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

9.74 kW

9.31 kW

COP Tj = Tbiv

2.82

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.3 kW

6.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.23 kW

5.67 kW

Annual energy consumption Qhe

7125 kWh

8997 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.48

9.04

COP Tj = -15°C (if TOL<-20°C)

2.77

2.19

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

152 %

Prated

12.5 kW

12.5 kW

SCOP

5.04

3.88

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.99 kW

11.06 kW

COP Tj = -7°C

2.77

2.25

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.52 kW

6.38 kW

COP Tj = +2°C

4.96

3.79

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

4.29 kW

4.12 kW

COP Tj = +7°C

6.97

5.26

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.23 kW

3.15 kW

COP Tj = 12°C

8.60

6.53

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.78 kW

11.64 kW

COP Tj = Tbiv

2.54

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.78 kW

11.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.15 kW

Annual energy consumption Qhe

5122 kWh

6653 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

163 %

COP

4.08

Heating up time

2:13 h:min

Standby power input

32 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.5

Heating up time

2:02 h:min

Standby power input

83 W

Reference hot water temperature

51.5 °C

Mixed water at 40°C

255 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

143 %

COP

3.56

Heating up time

2:12 h:min

Standby power input

35 W

Reference hot water temperature

51.5 °C

Mixed water at 40°C

253 l

WLW166i-10 MBB AR P3 T180 HK
Configure model
Model name
WLW166i-10 MBB AR P3 T180 HK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.1 kW

9.91 kW

El input

1.92 kW

3.29 kW

COP

4.73

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

179 %

Prated

10 kW

10 kW

SCOP

6.41

4.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.16 kW

9.67 kW

COP Tj = +2°C

3.54

2.55

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.18 kW

6.2 kW

COP Tj = +7°C

5.71

3.94

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

3.1 kW

2.95 kW

COP Tj = 12°C

7.81

5.68

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

10.16 kW

9.67 kW

COP Tj = Tbiv

3.54

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.2 kW

9.7 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.54

2.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2084 kWh

2932 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

136 %

Prated

10 kW

10 kW

SCOP

4.45

3.47

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.96 kW

6.06 kW

COP Tj = -7°C

3.77

2.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.26 kW

3.98 kW

COP Tj = +2°C

5.2

4.06

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.54 kW

3.36 kW

COP Tj = +7°C

6.67

5.14

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.07 kW

2.97 kW

COP Tj = 12°C

7.35

5.88

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

8.89 kW

8.46 kW

COP Tj = Tbiv

2.65

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.2 kW

6.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

3.2 kW

Annual energy consumption Qhe

5541 kWh

7105 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.46

8.02

COP Tj = -15°C (if TOL<-20°C)

2.84

2.23

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

154 %

Prated

10 kW

10 kW

SCOP

5.01

3.92

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.84 kW

8.80 kW

COP Tj = -7°C

3.10

2.50

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

5.68 kW

5.63 kW

COP Tj = +2°C

4.88

3.81

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

3.51 kW

3.46 kW

COP Tj = +7°C

6.62

5.05

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.12 kW

3.14 kW

COP Tj = 12°C

7.80

6.03

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

9.60 kW

9.31 kW

COP Tj = Tbiv

2.70

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.60 kW

9.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4123 kWh

5277 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

163 %

COP

4.08

Heating up time

2:13 h:min

Standby power input

32 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.5

Heating up time

2:02 h:min

Standby power input

83 W

Reference hot water temperature

51.5 °C

Mixed water at 40°C

255 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

143 %

COP

3.56

Heating up time

2:12 h:min

Standby power input

35 W

Reference hot water temperature

51.5 °C

Mixed water at 40°C

253 l

WLW166i-13 MBB AR P3 T180 HK
Configure model
Model name
WLW166i-13 MBB AR P3 T180 HK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.05 kW

13.15 kW

El input

2.48 kW

5.04 kW

COP

4.46

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

186 %

Prated

12.50 kW

12.50 kW

SCOP

6.41

4.72

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.29 kW

12.57 kW

COP Tj = +2°C

2.86

2.24

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

7.94 kW

7.81 kW

COP Tj = +7°C

5.59

3.90

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.60 kW

3.93 kW

COP Tj = 12°C

8.27

6.34

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.29 kW

12.57 kW

COP Tj = Tbiv

2.86

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

12.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3541 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

134 %

Prated

12.5 kW

12.5 kW

SCOP

4.33

3.43

Tbiv

-14 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.35 kW

7.42 kW

COP Tj = -7°C

3.67

2.88

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.28 kW

4.66 kW

COP Tj = +2°C

5.21

4.11

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.56 kW

3.4 kW

COP Tj = +7°C

6.89

5.38

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.08 kW

2.99 kW

COP Tj = 12°C

7.5

6.04

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

9.74 kW

9.31 kW

COP Tj = Tbiv

2.82

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.3 kW

6.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.23 kW

5.67 kW

Annual energy consumption Qhe

7125 kWh

8997 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.48

9.04

COP Tj = -15°C (if TOL<-20°C)

2.77

2.19

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

152 %

Prated

12.5 kW

12.5 kW

SCOP

5.04

3.88

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.99 kW

11.06 kW

COP Tj = -7°C

2.77

2.25

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.52 kW

6.38 kW

COP Tj = +2°C

4.96

3.79

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

4.29 kW

4.12 kW

COP Tj = +7°C

6.97

5.26

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.23 kW

3.15 kW

COP Tj = 12°C

8.60

6.53

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.78 kW

11.64 kW

COP Tj = Tbiv

2.54

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.78 kW

11.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.15 kW

Annual energy consumption Qhe

5122 kWh

6653 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

163 %

COP

4.08

Heating up time

2:13 h:min

Standby power input

32 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.5

Heating up time

2:02 h:min

Standby power input

83 W

Reference hot water temperature

51.5 °C

Mixed water at 40°C

255 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

143 %

COP

3.56

Heating up time

2:12 h:min

Standby power input

35 W

Reference hot water temperature

51.5 °C

Mixed water at 40°C

253 l

WLW176i.2-10 MBB AR P3 E
Configure model
Model name
WLW176i.2-10 MBB AR P3 E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.1 kW

9.91 kW

El input

1.92 kW

3.29 kW

COP

4.73

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

179 %

Prated

10 kW

10 kW

SCOP

6.41

4.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.16 kW

9.67 kW

COP Tj = +2°C

3.54

2.55

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.18 kW

6.2 kW

COP Tj = +7°C

5.71

3.94

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

3.1 kW

2.95 kW

COP Tj = 12°C

7.81

5.68

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

10.16 kW

9.67 kW

COP Tj = Tbiv

3.54

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.2 kW

9.7 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.54

2.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2084 kWh

2932 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

136 %

Prated

10 kW

10 kW

SCOP

4.45

3.47

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.96 kW

6.06 kW

COP Tj = -7°C

3.77

2.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.26 kW

3.98 kW

COP Tj = +2°C

5.2

4.06

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.54 kW

3.36 kW

COP Tj = +7°C

6.67

5.14

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.07 kW

2.97 kW

COP Tj = 12°C

7.35

5.88

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

8.89 kW

8.46 kW

COP Tj = Tbiv

2.65

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.2 kW

6.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

3.2 kW

Annual energy consumption Qhe

5541 kWh

7105 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.46

8.02

COP Tj = -15°C (if TOL<-20°C)

2.84

2.23

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

154 %

Prated

10 kW

10 kW

SCOP

5.01

3.92

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.84 kW

8.80 kW

COP Tj = -7°C

3.10

2.50

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

5.68 kW

5.63 kW

COP Tj = +2°C

4.88

3.81

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

3.51 kW

3.46 kW

COP Tj = +7°C

6.62

5.05

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.12 kW

3.14 kW

COP Tj = 12°C

7.80

6.03

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

9.60 kW

9.31 kW

COP Tj = Tbiv

2.70

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.60 kW

9.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4123 kWh

5277 kWh

WLW176i.2-13 MBB AR P3 E
Configure model
Model name
WLW176i.2-13 MBB AR P3 E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.05 kW

13.15 kW

El input

2.48 kW

5.04 kW

COP

4.46

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

186 %

Prated

12.50 kW

12.50 kW

SCOP

6.41

4.72

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.29 kW

12.57 kW

COP Tj = +2°C

2.86

2.24

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

7.94 kW

7.81 kW

COP Tj = +7°C

5.59

3.90

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.60 kW

3.93 kW

COP Tj = 12°C

8.27

6.34

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.29 kW

12.57 kW

COP Tj = Tbiv

2.86

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

12.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3541 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

134 %

Prated

12.5 kW

12.5 kW

SCOP

4.33

3.43

Tbiv

-14 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.35 kW

7.42 kW

COP Tj = -7°C

3.67

2.88

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.28 kW

4.66 kW

COP Tj = +2°C

5.21

4.11

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.56 kW

3.4 kW

COP Tj = +7°C

6.89

5.38

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.08 kW

2.99 kW

COP Tj = 12°C

7.5

6.04

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

9.74 kW

9.31 kW

COP Tj = Tbiv

2.82

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.3 kW

6.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.23 kW

5.67 kW

Annual energy consumption Qhe

7125 kWh

8997 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.48

9.04

COP Tj = -15°C (if TOL<-20°C)

2.77

2.19

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

152 %

Prated

12.5 kW

12.5 kW

SCOP

5.04

3.88

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.99 kW

11.06 kW

COP Tj = -7°C

2.77

2.25

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.52 kW

6.38 kW

COP Tj = +2°C

4.96

3.79

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

4.29 kW

4.12 kW

COP Tj = +7°C

6.97

5.26

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.23 kW

3.15 kW

COP Tj = 12°C

8.60

6.53

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.78 kW

11.64 kW

COP Tj = Tbiv

2.54

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.78 kW

11.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.15 kW

Annual energy consumption Qhe

5122 kWh

6653 kWh

WLW-10 FMBB AR P3 WPM400 S
Configure model
Model name
WLW-10 FMBB AR P3 WPM400 S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.1 kW

9.91 kW

El input

1.92 kW

3.29 kW

COP

4.73

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

179 %

Prated

10 kW

10 kW

SCOP

6.41

4.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.16 kW

9.67 kW

COP Tj = +2°C

3.54

2.55

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.18 kW

6.2 kW

COP Tj = +7°C

5.71

3.94

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

3.1 kW

2.95 kW

COP Tj = 12°C

7.81

5.68

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

10.16 kW

9.67 kW

COP Tj = Tbiv

3.54

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.2 kW

9.7 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.54

2.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2084 kWh

2932 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

136 %

Prated

10 kW

10 kW

SCOP

4.45

3.47

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.96 kW

6.06 kW

COP Tj = -7°C

3.77

2.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.26 kW

3.98 kW

COP Tj = +2°C

5.2

4.06

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.54 kW

3.36 kW

COP Tj = +7°C

6.67

5.14

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.07 kW

2.97 kW

COP Tj = 12°C

7.35

5.88

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

8.89 kW

8.46 kW

COP Tj = Tbiv

2.65

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.2 kW

6.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

3.2 kW

Annual energy consumption Qhe

5541 kWh

7105 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.46

8.02

COP Tj = -15°C (if TOL<-20°C)

2.84

2.23

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

154 %

Prated

10 kW

10 kW

SCOP

5.01

3.92

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.84 kW

8.80 kW

COP Tj = -7°C

3.10

2.50

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

5.68 kW

5.63 kW

COP Tj = +2°C

4.88

3.81

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

3.51 kW

3.46 kW

COP Tj = +7°C

6.62

5.05

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.12 kW

3.14 kW

COP Tj = 12°C

7.80

6.03

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

9.60 kW

9.31 kW

COP Tj = Tbiv

2.70

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.60 kW

9.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4123 kWh

5277 kWh

WLW-13 FMBB AR P3 WPM400 S
Configure model
Model name
WLW-13 FMBB AR P3 WPM400 S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.05 kW

13.15 kW

El input

2.48 kW

5.04 kW

COP

4.46

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

186 %

Prated

12.50 kW

12.50 kW

SCOP

6.41

4.72

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.29 kW

12.57 kW

COP Tj = +2°C

2.86

2.24

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

7.94 kW

7.81 kW

COP Tj = +7°C

5.59

3.90

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.60 kW

3.93 kW

COP Tj = 12°C

8.27

6.34

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.29 kW

12.57 kW

COP Tj = Tbiv

2.86

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

12.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3541 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

134 %

Prated

12.5 kW

12.5 kW

SCOP

4.33

3.43

Tbiv

-14 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.35 kW

7.42 kW

COP Tj = -7°C

3.67

2.88

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.28 kW

4.66 kW

COP Tj = +2°C

5.21

4.11

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.56 kW

3.4 kW

COP Tj = +7°C

6.89

5.38

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.08 kW

2.99 kW

COP Tj = 12°C

7.5

6.04

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

9.74 kW

9.31 kW

COP Tj = Tbiv

2.82

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.3 kW

6.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.23 kW

5.67 kW

Annual energy consumption Qhe

7125 kWh

8997 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.48

9.04

COP Tj = -15°C (if TOL<-20°C)

2.77

2.19

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

152 %

Prated

12.5 kW

12.5 kW

SCOP

5.04

3.88

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.99 kW

11.06 kW

COP Tj = -7°C

2.77

2.25

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.52 kW

6.38 kW

COP Tj = +2°C

4.96

3.79

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

4.29 kW

4.12 kW

COP Tj = +7°C

6.97

5.26

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.23 kW

3.15 kW

COP Tj = 12°C

8.60

6.53

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.78 kW

11.64 kW

COP Tj = Tbiv

2.54

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.78 kW

11.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

17 W

17 W

PTO

7 W

7 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.15 kW

Annual energy consumption Qhe

5122 kWh

6653 kWh

WLW-10 MBB A H P3
Configure model
Model name
WLW-10 MBB A H P3
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.13 kW

9.92 kW

El input

1.99 kW

3.32 kW

COP

4.58

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

171 %

Prated

10.00 kW

10.00 kW

SCOP

5.96

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.19 kW

9.68 kW

COP Tj = +2°C

3.45

2.53

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

6.18 kW

6.20 kW

COP Tj = +7°C

5.54

3.89

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.10 kW

2.94 kW

COP Tj = 12°C

7.40

5.47

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

10.19 kW

9.68 kW

COP Tj = Tbiv

3.45

2.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.19 kW

9.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.45

2.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2242 kWh

3079 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

133 %

Prated

10.00 kW

10.00 kW

SCOP

4.29

3.39

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.97 kW

6.06 kW

COP Tj = -7°C

3.70

2.89

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

4.26 kW

3.98 kW

COP Tj = +2°C

5.05

3.97

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

3.54 kW

3.36 kW

COP Tj = +7°C

6.41

4.98

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.07 kW

2.97 kW

COP Tj = 12°C

6.99

5.65

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

8.92 kW

8.46 kW

COP Tj = Tbiv

2.61

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.25 kW

6.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.75 kW

3.19 kW

Annual energy consumption Qhe

5742 kWh

7275 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.48

8.02

COP Tj = -15°C (if TOL<-20°C)

2.79

2.21

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

149 %

Prated

10.00 kW

10.00 kW

SCOP

4.79

3.80

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.86 kW

8.78 kW

COP Tj = -7°C

3.04

2.48

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.69 kW

5.60 kW

COP Tj = +2°C

4.75

3.75

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.51 kW

3.44 kW

COP Tj = +7°C

6.35

4.90

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.12 kW

3.12 kW

COP Tj = 12°C

7.40

5.80

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

9.63 kW

9.30 kW

COP Tj = Tbiv

2.65

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.62 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4312 kWh

5440 kWh

WLW-13 MBB A H P3
Configure model
Model name
WLW-13 MBB A H P3
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.09 kW

13.16 kW

El input

2.56 kW

5.08 kW

COP

4.33

2.59

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

178 %

Prated

12.50 kW

12.50 kW

SCOP

6.00

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.33 kW

12.58 kW

COP Tj = +2°C

2.81

2.22

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.95 kW

7.81 kW

COP Tj = +7°C

5.41

3.85

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.57 kW

3.93 kW

COP Tj = 12°C

7.86

6.14

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

12.33 kW

12.58 kW

COP Tj = Tbiv

2.81

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.33 kW

12.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

2.22

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2781 kWh

3694 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

131 %

Prated

12.50 kW

12.50 kW

SCOP

4.19

3.36

Tbiv

-14 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.36 kW

7.42 kW

COP Tj = -7°C

3.60

2.85

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.28 kW

4.66 kW

COP Tj = +2°C

5.07

4.04

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.56 kW

3.40 kW

COP Tj = +7°C

6.61

5.21

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.08 kW

2.99 kW

COP Tj = 12°C

7.12

5.80

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

9.77 kW

9.31 kW

COP Tj = Tbiv

2.77

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.28 kW

6.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.22 kW

5.67 kW

Annual energy consumption Qhe

7347 kWh

9176 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.50

9.04

COP Tj = -15°C (if TOL<-20°C)

2.72

2.18

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

149 %

Prated

12.50 kW

12.50 kW

SCOP

4.83

3.79

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.03 kW

11.06 kW

COP Tj = -7°C

2.70

2.24

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.53 kW

6.39 kW

COP Tj = +2°C

4.83

3.74

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.29 kW

4.12 kW

COP Tj = +7°C

6.71

5.13

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.23 kW

3.15 kW

COP Tj = 12°C

8.16

6.31

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

12.82 kW

11.65 kW

COP Tj = Tbiv

2.47

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.82 kW

11.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.14 kW

Annual energy consumption Qhe

5342 kWh

6818 kWh

WLW-10 MBB A H P3 GBH172i
Configure model
Model name
WLW-10 MBB A H P3 GBH172i
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.13 kW

9.92 kW

El input

1.99 kW

3.32 kW

COP

4.58

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

171 %

Prated

10.00 kW

10.00 kW

SCOP

5.96

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.19 kW

9.68 kW

COP Tj = +2°C

3.45

2.53

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

6.18 kW

6.20 kW

COP Tj = +7°C

5.54

3.89

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.10 kW

2.94 kW

COP Tj = 12°C

7.40

5.47

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

10.19 kW

9.68 kW

COP Tj = Tbiv

3.45

2.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.19 kW

9.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.45

2.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2242 kWh

3079 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

133 %

Prated

10.00 kW

10.00 kW

SCOP

4.29

3.39

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.97 kW

6.06 kW

COP Tj = -7°C

3.70

2.89

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

4.26 kW

3.98 kW

COP Tj = +2°C

5.05

3.97

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

3.54 kW

3.36 kW

COP Tj = +7°C

6.41

4.98

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.07 kW

2.97 kW

COP Tj = 12°C

6.99

5.65

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

8.92 kW

8.46 kW

COP Tj = Tbiv

2.61

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.25 kW

6.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.75 kW

3.19 kW

Annual energy consumption Qhe

5742 kWh

7275 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.48

8.02

COP Tj = -15°C (if TOL<-20°C)

2.79

2.21

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

149 %

Prated

10.00 kW

10.00 kW

SCOP

4.79

3.80

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.86 kW

8.78 kW

COP Tj = -7°C

3.04

2.48

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.69 kW

5.60 kW

COP Tj = +2°C

4.75

3.75

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.51 kW

3.44 kW

COP Tj = +7°C

6.35

4.90

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.12 kW

3.12 kW

COP Tj = 12°C

7.40

5.80

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

9.63 kW

9.30 kW

COP Tj = Tbiv

2.65

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.62 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4312 kWh

5440 kWh

WLW-13 MBB A H P3 GBH172i
Configure model
Model name
WLW-13 MBB A H P3 GBH172i
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.09 kW

13.16 kW

El input

2.56 kW

5.08 kW

COP

4.33

2.59

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

178 %

Prated

12.50 kW

12.50 kW

SCOP

6.00

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.33 kW

12.58 kW

COP Tj = +2°C

2.81

2.22

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.95 kW

7.81 kW

COP Tj = +7°C

5.41

3.85

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.57 kW

3.93 kW

COP Tj = 12°C

7.86

6.14

Cdh Tj = +12 °C

0.940

0.960

Pdh Tj = Tbiv

12.33 kW

12.58 kW

COP Tj = Tbiv

2.81

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.33 kW

12.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

2.22

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2781 kWh

3694 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

131 %

Prated

12.50 kW

12.50 kW

SCOP

4.19

3.36

Tbiv

-14 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.36 kW

7.42 kW

COP Tj = -7°C

3.60

2.85

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.28 kW

4.66 kW

COP Tj = +2°C

5.07

4.04

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.56 kW

3.40 kW

COP Tj = +7°C

6.61

5.21

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.08 kW

2.99 kW

COP Tj = 12°C

7.12

5.80

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

9.77 kW

9.31 kW

COP Tj = Tbiv

2.77

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.28 kW

6.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.22 kW

5.67 kW

Annual energy consumption Qhe

7347 kWh

9176 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.50

9.04

COP Tj = -15°C (if TOL<-20°C)

2.72

2.18

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

149 %

Prated

12.50 kW

12.50 kW

SCOP

4.83

3.79

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.03 kW

11.06 kW

COP Tj = -7°C

2.70

2.24

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.53 kW

6.39 kW

COP Tj = +2°C

4.83

3.74

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

4.29 kW

4.12 kW

COP Tj = +7°C

6.71

5.13

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.23 kW

3.15 kW

COP Tj = 12°C

8.16

6.31

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

12.82 kW

11.65 kW

COP Tj = Tbiv

2.47

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.82 kW

11.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

26 W

26 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.14 kW

Annual energy consumption Qhe

5342 kWh

6818 kWh