1,365 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.1 kW
9.91 kW
El input
1.92 kW
3.29 kW
COP
4.73
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
179 %
Prated
10 kW
10 kW
SCOP
6.41
4.56
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.16 kW
9.67 kW
COP Tj = +2°C
3.54
2.55
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.18 kW
6.2 kW
COP Tj = +7°C
5.71
3.94
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
3.1 kW
2.95 kW
COP Tj = 12°C
7.81
5.68
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
10.16 kW
9.67 kW
COP Tj = Tbiv
3.54
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.2 kW
9.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2084 kWh
2932 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
136 %
Prated
10 kW
10 kW
SCOP
4.45
3.47
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.96 kW
6.06 kW
COP Tj = -7°C
3.77
2.92
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.26 kW
3.98 kW
COP Tj = +2°C
5.2
4.06
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.54 kW
3.36 kW
COP Tj = +7°C
6.67
5.14
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.07 kW
2.97 kW
COP Tj = 12°C
7.35
5.88
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
8.89 kW
8.46 kW
COP Tj = Tbiv
2.65
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.2 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.76 kW
3.2 kW
Annual energy consumption Qhe
5541 kWh
7105 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.46
8.02
COP Tj = -15°C (if TOL<-20°C)
2.84
2.23
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
154 %
Prated
10 kW
10 kW
SCOP
5.01
3.92
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.84 kW
8.80 kW
COP Tj = -7°C
3.10
2.50
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.68 kW
5.63 kW
COP Tj = +2°C
4.88
3.81
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
3.51 kW
3.46 kW
COP Tj = +7°C
6.62
5.05
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.12 kW
3.14 kW
COP Tj = 12°C
7.80
6.03
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
9.60 kW
9.31 kW
COP Tj = Tbiv
2.70
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.60 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4123 kWh
5277 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
163 %
COP
4.08
Heating up time
2:13 h:min
Standby power input
32 W
Reference hot water temperature
51.4 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.5
Heating up time
2:02 h:min
Standby power input
83 W
Reference hot water temperature
51.5 °C
Mixed water at 40°C
255 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
143 %
COP
3.56
Heating up time
2:12 h:min
Standby power input
35 W
Reference hot water temperature
51.5 °C
Mixed water at 40°C
253 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.05 kW
13.15 kW
El input
2.48 kW
5.04 kW
COP
4.46
2.61
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
254 %
186 %
Prated
12.50 kW
12.50 kW
SCOP
6.41
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.29 kW
12.57 kW
COP Tj = +2°C
2.86
2.24
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.94 kW
7.81 kW
COP Tj = +7°C
5.59
3.90
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
3.60 kW
3.93 kW
COP Tj = 12°C
8.27
6.34
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.29 kW
12.57 kW
COP Tj = Tbiv
2.86
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.30 kW
12.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2674 kWh
3541 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
134 %
Prated
12.5 kW
12.5 kW
SCOP
4.33
3.43
Tbiv
-14 °C
-14 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.35 kW
7.42 kW
COP Tj = -7°C
3.67
2.88
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.28 kW
4.66 kW
COP Tj = +2°C
5.21
4.11
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.56 kW
3.4 kW
COP Tj = +7°C
6.89
5.38
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.08 kW
2.99 kW
COP Tj = 12°C
7.5
6.04
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
9.74 kW
9.31 kW
COP Tj = Tbiv
2.82
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.3 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.38
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.23 kW
5.67 kW
Annual energy consumption Qhe
7125 kWh
8997 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.48
9.04
COP Tj = -15°C (if TOL<-20°C)
2.77
2.19
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
152 %
Prated
12.5 kW
12.5 kW
SCOP
5.04
3.88
Tbiv
-10 °C
-9 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.99 kW
11.06 kW
COP Tj = -7°C
2.77
2.25
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.52 kW
6.38 kW
COP Tj = +2°C
4.96
3.79
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.29 kW
4.12 kW
COP Tj = +7°C
6.97
5.26
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.23 kW
3.15 kW
COP Tj = 12°C
8.60
6.53
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.78 kW
11.64 kW
COP Tj = Tbiv
2.54
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.78 kW
11.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.15 kW
Annual energy consumption Qhe
5122 kWh
6653 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
163 %
COP
4.08
Heating up time
2:13 h:min
Standby power input
32 W
Reference hot water temperature
51.4 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.5
Heating up time
2:02 h:min
Standby power input
83 W
Reference hot water temperature
51.5 °C
Mixed water at 40°C
255 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
143 %
COP
3.56
Heating up time
2:12 h:min
Standby power input
35 W
Reference hot water temperature
51.5 °C
Mixed water at 40°C
253 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.1 kW
9.91 kW
El input
1.92 kW
3.29 kW
COP
4.73
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
179 %
Prated
10 kW
10 kW
SCOP
6.41
4.56
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.16 kW
9.67 kW
COP Tj = +2°C
3.54
2.55
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.18 kW
6.2 kW
COP Tj = +7°C
5.71
3.94
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
3.1 kW
2.95 kW
COP Tj = 12°C
7.81
5.68
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
10.16 kW
9.67 kW
COP Tj = Tbiv
3.54
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.2 kW
9.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2084 kWh
2932 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
136 %
Prated
10 kW
10 kW
SCOP
4.45
3.47
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.96 kW
6.06 kW
COP Tj = -7°C
3.77
2.92
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.26 kW
3.98 kW
COP Tj = +2°C
5.2
4.06
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.54 kW
3.36 kW
COP Tj = +7°C
6.67
5.14
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.07 kW
2.97 kW
COP Tj = 12°C
7.35
5.88
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
8.89 kW
8.46 kW
COP Tj = Tbiv
2.65
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.2 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.76 kW
3.2 kW
Annual energy consumption Qhe
5541 kWh
7105 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.46
8.02
COP Tj = -15°C (if TOL<-20°C)
2.84
2.23
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
154 %
Prated
10 kW
10 kW
SCOP
5.01
3.92
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.84 kW
8.80 kW
COP Tj = -7°C
3.10
2.50
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.68 kW
5.63 kW
COP Tj = +2°C
4.88
3.81
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
3.51 kW
3.46 kW
COP Tj = +7°C
6.62
5.05
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.12 kW
3.14 kW
COP Tj = 12°C
7.80
6.03
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
9.60 kW
9.31 kW
COP Tj = Tbiv
2.70
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.60 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4123 kWh
5277 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
163 %
COP
4.08
Heating up time
2:13 h:min
Standby power input
32 W
Reference hot water temperature
51.4 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.5
Heating up time
2:02 h:min
Standby power input
83 W
Reference hot water temperature
51.5 °C
Mixed water at 40°C
255 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
143 %
COP
3.56
Heating up time
2:12 h:min
Standby power input
35 W
Reference hot water temperature
51.5 °C
Mixed water at 40°C
253 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.05 kW
13.15 kW
El input
2.48 kW
5.04 kW
COP
4.46
2.61
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
254 %
186 %
Prated
12.50 kW
12.50 kW
SCOP
6.41
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.29 kW
12.57 kW
COP Tj = +2°C
2.86
2.24
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.94 kW
7.81 kW
COP Tj = +7°C
5.59
3.90
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
3.60 kW
3.93 kW
COP Tj = 12°C
8.27
6.34
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.29 kW
12.57 kW
COP Tj = Tbiv
2.86
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.30 kW
12.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2674 kWh
3541 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
134 %
Prated
12.5 kW
12.5 kW
SCOP
4.33
3.43
Tbiv
-14 °C
-14 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.35 kW
7.42 kW
COP Tj = -7°C
3.67
2.88
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.28 kW
4.66 kW
COP Tj = +2°C
5.21
4.11
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.56 kW
3.4 kW
COP Tj = +7°C
6.89
5.38
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.08 kW
2.99 kW
COP Tj = 12°C
7.5
6.04
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
9.74 kW
9.31 kW
COP Tj = Tbiv
2.82
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.3 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.38
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.23 kW
5.67 kW
Annual energy consumption Qhe
7125 kWh
8997 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.48
9.04
COP Tj = -15°C (if TOL<-20°C)
2.77
2.19
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
152 %
Prated
12.5 kW
12.5 kW
SCOP
5.04
3.88
Tbiv
-10 °C
-9 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.99 kW
11.06 kW
COP Tj = -7°C
2.77
2.25
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.52 kW
6.38 kW
COP Tj = +2°C
4.96
3.79
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.29 kW
4.12 kW
COP Tj = +7°C
6.97
5.26
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.23 kW
3.15 kW
COP Tj = 12°C
8.60
6.53
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.78 kW
11.64 kW
COP Tj = Tbiv
2.54
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.78 kW
11.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.15 kW
Annual energy consumption Qhe
5122 kWh
6653 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
163 %
COP
4.08
Heating up time
2:13 h:min
Standby power input
32 W
Reference hot water temperature
51.4 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.5
Heating up time
2:02 h:min
Standby power input
83 W
Reference hot water temperature
51.5 °C
Mixed water at 40°C
255 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
143 %
COP
3.56
Heating up time
2:12 h:min
Standby power input
35 W
Reference hot water temperature
51.5 °C
Mixed water at 40°C
253 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.1 kW
9.91 kW
El input
1.92 kW
3.29 kW
COP
4.73
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
179 %
Prated
10 kW
10 kW
SCOP
6.41
4.56
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.16 kW
9.67 kW
COP Tj = +2°C
3.54
2.55
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.18 kW
6.2 kW
COP Tj = +7°C
5.71
3.94
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
3.1 kW
2.95 kW
COP Tj = 12°C
7.81
5.68
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
10.16 kW
9.67 kW
COP Tj = Tbiv
3.54
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.2 kW
9.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2084 kWh
2932 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
136 %
Prated
10 kW
10 kW
SCOP
4.45
3.47
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.96 kW
6.06 kW
COP Tj = -7°C
3.77
2.92
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.26 kW
3.98 kW
COP Tj = +2°C
5.2
4.06
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.54 kW
3.36 kW
COP Tj = +7°C
6.67
5.14
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.07 kW
2.97 kW
COP Tj = 12°C
7.35
5.88
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
8.89 kW
8.46 kW
COP Tj = Tbiv
2.65
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.2 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.76 kW
3.2 kW
Annual energy consumption Qhe
5541 kWh
7105 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.46
8.02
COP Tj = -15°C (if TOL<-20°C)
2.84
2.23
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
154 %
Prated
10 kW
10 kW
SCOP
5.01
3.92
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.84 kW
8.80 kW
COP Tj = -7°C
3.10
2.50
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.68 kW
5.63 kW
COP Tj = +2°C
4.88
3.81
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
3.51 kW
3.46 kW
COP Tj = +7°C
6.62
5.05
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.12 kW
3.14 kW
COP Tj = 12°C
7.80
6.03
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
9.60 kW
9.31 kW
COP Tj = Tbiv
2.70
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.60 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4123 kWh
5277 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.05 kW
13.15 kW
El input
2.48 kW
5.04 kW
COP
4.46
2.61
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
254 %
186 %
Prated
12.50 kW
12.50 kW
SCOP
6.41
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.29 kW
12.57 kW
COP Tj = +2°C
2.86
2.24
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.94 kW
7.81 kW
COP Tj = +7°C
5.59
3.90
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
3.60 kW
3.93 kW
COP Tj = 12°C
8.27
6.34
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.29 kW
12.57 kW
COP Tj = Tbiv
2.86
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.30 kW
12.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2674 kWh
3541 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
134 %
Prated
12.5 kW
12.5 kW
SCOP
4.33
3.43
Tbiv
-14 °C
-14 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.35 kW
7.42 kW
COP Tj = -7°C
3.67
2.88
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.28 kW
4.66 kW
COP Tj = +2°C
5.21
4.11
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.56 kW
3.4 kW
COP Tj = +7°C
6.89
5.38
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.08 kW
2.99 kW
COP Tj = 12°C
7.5
6.04
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
9.74 kW
9.31 kW
COP Tj = Tbiv
2.82
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.3 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.38
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.23 kW
5.67 kW
Annual energy consumption Qhe
7125 kWh
8997 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.48
9.04
COP Tj = -15°C (if TOL<-20°C)
2.77
2.19
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
152 %
Prated
12.5 kW
12.5 kW
SCOP
5.04
3.88
Tbiv
-10 °C
-9 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.99 kW
11.06 kW
COP Tj = -7°C
2.77
2.25
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.52 kW
6.38 kW
COP Tj = +2°C
4.96
3.79
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.29 kW
4.12 kW
COP Tj = +7°C
6.97
5.26
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.23 kW
3.15 kW
COP Tj = 12°C
8.60
6.53
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.78 kW
11.64 kW
COP Tj = Tbiv
2.54
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.78 kW
11.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.15 kW
Annual energy consumption Qhe
5122 kWh
6653 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.1 kW
9.91 kW
El input
1.92 kW
3.29 kW
COP
4.73
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
179 %
Prated
10 kW
10 kW
SCOP
6.41
4.56
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.16 kW
9.67 kW
COP Tj = +2°C
3.54
2.55
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.18 kW
6.2 kW
COP Tj = +7°C
5.71
3.94
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
3.1 kW
2.95 kW
COP Tj = 12°C
7.81
5.68
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
10.16 kW
9.67 kW
COP Tj = Tbiv
3.54
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.2 kW
9.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2084 kWh
2932 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
136 %
Prated
10 kW
10 kW
SCOP
4.45
3.47
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.96 kW
6.06 kW
COP Tj = -7°C
3.77
2.92
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.26 kW
3.98 kW
COP Tj = +2°C
5.2
4.06
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.54 kW
3.36 kW
COP Tj = +7°C
6.67
5.14
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.07 kW
2.97 kW
COP Tj = 12°C
7.35
5.88
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
8.89 kW
8.46 kW
COP Tj = Tbiv
2.65
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.2 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.76 kW
3.2 kW
Annual energy consumption Qhe
5541 kWh
7105 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.46
8.02
COP Tj = -15°C (if TOL<-20°C)
2.84
2.23
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
154 %
Prated
10 kW
10 kW
SCOP
5.01
3.92
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.84 kW
8.80 kW
COP Tj = -7°C
3.10
2.50
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.68 kW
5.63 kW
COP Tj = +2°C
4.88
3.81
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
3.51 kW
3.46 kW
COP Tj = +7°C
6.62
5.05
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.12 kW
3.14 kW
COP Tj = 12°C
7.80
6.03
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
9.60 kW
9.31 kW
COP Tj = Tbiv
2.70
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.60 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4123 kWh
5277 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.05 kW
13.15 kW
El input
2.48 kW
5.04 kW
COP
4.46
2.61
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
254 %
186 %
Prated
12.50 kW
12.50 kW
SCOP
6.41
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.29 kW
12.57 kW
COP Tj = +2°C
2.86
2.24
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.94 kW
7.81 kW
COP Tj = +7°C
5.59
3.90
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
3.60 kW
3.93 kW
COP Tj = 12°C
8.27
6.34
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.29 kW
12.57 kW
COP Tj = Tbiv
2.86
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.30 kW
12.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2674 kWh
3541 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
134 %
Prated
12.5 kW
12.5 kW
SCOP
4.33
3.43
Tbiv
-14 °C
-14 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.35 kW
7.42 kW
COP Tj = -7°C
3.67
2.88
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.28 kW
4.66 kW
COP Tj = +2°C
5.21
4.11
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.56 kW
3.4 kW
COP Tj = +7°C
6.89
5.38
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.08 kW
2.99 kW
COP Tj = 12°C
7.5
6.04
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
9.74 kW
9.31 kW
COP Tj = Tbiv
2.82
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.3 kW
6.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.38
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.23 kW
5.67 kW
Annual energy consumption Qhe
7125 kWh
8997 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.48
9.04
COP Tj = -15°C (if TOL<-20°C)
2.77
2.19
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
152 %
Prated
12.5 kW
12.5 kW
SCOP
5.04
3.88
Tbiv
-10 °C
-9 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.99 kW
11.06 kW
COP Tj = -7°C
2.77
2.25
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.52 kW
6.38 kW
COP Tj = +2°C
4.96
3.79
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.29 kW
4.12 kW
COP Tj = +7°C
6.97
5.26
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.23 kW
3.15 kW
COP Tj = 12°C
8.60
6.53
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.78 kW
11.64 kW
COP Tj = Tbiv
2.54
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.78 kW
11.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
7 W
7 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.15 kW
Annual energy consumption Qhe
5122 kWh
6653 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.13 kW
9.92 kW
El input
1.99 kW
3.32 kW
COP
4.58
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
235 %
171 %
Prated
10.00 kW
10.00 kW
SCOP
5.96
4.34
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.19 kW
9.68 kW
COP Tj = +2°C
3.45
2.53
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.18 kW
6.20 kW
COP Tj = +7°C
5.54
3.89
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.10 kW
2.94 kW
COP Tj = 12°C
7.40
5.47
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
10.19 kW
9.68 kW
COP Tj = Tbiv
3.45
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.19 kW
9.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.45
2.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2242 kWh
3079 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
133 %
Prated
10.00 kW
10.00 kW
SCOP
4.29
3.39
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.97 kW
6.06 kW
COP Tj = -7°C
3.70
2.89
Cdh Tj = -7 °C
0.980
0.990
Pdh Tj = +2°C
4.26 kW
3.98 kW
COP Tj = +2°C
5.05
3.97
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
3.54 kW
3.36 kW
COP Tj = +7°C
6.41
4.98
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.07 kW
2.97 kW
COP Tj = 12°C
6.99
5.65
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
8.92 kW
8.46 kW
COP Tj = Tbiv
2.61
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.25 kW
6.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.75 kW
3.19 kW
Annual energy consumption Qhe
5742 kWh
7275 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.48
8.02
COP Tj = -15°C (if TOL<-20°C)
2.79
2.21
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
149 %
Prated
10.00 kW
10.00 kW
SCOP
4.79
3.80
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.86 kW
8.78 kW
COP Tj = -7°C
3.04
2.48
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.69 kW
5.60 kW
COP Tj = +2°C
4.75
3.75
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.51 kW
3.44 kW
COP Tj = +7°C
6.35
4.90
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.12 kW
3.12 kW
COP Tj = 12°C
7.40
5.80
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
9.63 kW
9.30 kW
COP Tj = Tbiv
2.65
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.62 kW
9.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4312 kWh
5440 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.09 kW
13.16 kW
El input
2.56 kW
5.08 kW
COP
4.33
2.59
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
178 %
Prated
12.50 kW
12.50 kW
SCOP
6.00
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.33 kW
12.58 kW
COP Tj = +2°C
2.81
2.22
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.95 kW
7.81 kW
COP Tj = +7°C
5.41
3.85
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.57 kW
3.93 kW
COP Tj = 12°C
7.86
6.14
Cdh Tj = +12 °C
0.940
0.960
Pdh Tj = Tbiv
12.33 kW
12.58 kW
COP Tj = Tbiv
2.81
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.33 kW
12.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2781 kWh
3694 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
131 %
Prated
12.50 kW
12.50 kW
SCOP
4.19
3.36
Tbiv
-14 °C
-14 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.36 kW
7.42 kW
COP Tj = -7°C
3.60
2.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.28 kW
4.66 kW
COP Tj = +2°C
5.07
4.04
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
3.56 kW
3.40 kW
COP Tj = +7°C
6.61
5.21
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.08 kW
2.99 kW
COP Tj = 12°C
7.12
5.80
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
9.77 kW
9.31 kW
COP Tj = Tbiv
2.77
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.28 kW
6.83 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.22 kW
5.67 kW
Annual energy consumption Qhe
7347 kWh
9176 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.50
9.04
COP Tj = -15°C (if TOL<-20°C)
2.72
2.18
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
149 %
Prated
12.50 kW
12.50 kW
SCOP
4.83
3.79
Tbiv
-10 °C
-9 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.03 kW
11.06 kW
COP Tj = -7°C
2.70
2.24
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
6.53 kW
6.39 kW
COP Tj = +2°C
4.83
3.74
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.29 kW
4.12 kW
COP Tj = +7°C
6.71
5.13
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
3.23 kW
3.15 kW
COP Tj = 12°C
8.16
6.31
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
12.82 kW
11.65 kW
COP Tj = Tbiv
2.47
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.82 kW
11.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.47
1.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.14 kW
Annual energy consumption Qhe
5342 kWh
6818 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.13 kW
9.92 kW
El input
1.99 kW
3.32 kW
COP
4.58
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
235 %
171 %
Prated
10.00 kW
10.00 kW
SCOP
5.96
4.34
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.19 kW
9.68 kW
COP Tj = +2°C
3.45
2.53
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.18 kW
6.20 kW
COP Tj = +7°C
5.54
3.89
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.10 kW
2.94 kW
COP Tj = 12°C
7.40
5.47
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
10.19 kW
9.68 kW
COP Tj = Tbiv
3.45
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.19 kW
9.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.45
2.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2242 kWh
3079 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
133 %
Prated
10.00 kW
10.00 kW
SCOP
4.29
3.39
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.97 kW
6.06 kW
COP Tj = -7°C
3.70
2.89
Cdh Tj = -7 °C
0.980
0.990
Pdh Tj = +2°C
4.26 kW
3.98 kW
COP Tj = +2°C
5.05
3.97
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
3.54 kW
3.36 kW
COP Tj = +7°C
6.41
4.98
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.07 kW
2.97 kW
COP Tj = 12°C
6.99
5.65
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
8.92 kW
8.46 kW
COP Tj = Tbiv
2.61
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.25 kW
6.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.75 kW
3.19 kW
Annual energy consumption Qhe
5742 kWh
7275 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.48
8.02
COP Tj = -15°C (if TOL<-20°C)
2.79
2.21
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
49 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
149 %
Prated
10.00 kW
10.00 kW
SCOP
4.79
3.80
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.86 kW
8.78 kW
COP Tj = -7°C
3.04
2.48
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.69 kW
5.60 kW
COP Tj = +2°C
4.75
3.75
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.51 kW
3.44 kW
COP Tj = +7°C
6.35
4.90
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.12 kW
3.12 kW
COP Tj = 12°C
7.40
5.80
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
9.63 kW
9.30 kW
COP Tj = Tbiv
2.65
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.62 kW
9.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4312 kWh
5440 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.09 kW
13.16 kW
El input
2.56 kW
5.08 kW
COP
4.33
2.59
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
178 %
Prated
12.50 kW
12.50 kW
SCOP
6.00
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.33 kW
12.58 kW
COP Tj = +2°C
2.81
2.22
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.95 kW
7.81 kW
COP Tj = +7°C
5.41
3.85
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.57 kW
3.93 kW
COP Tj = 12°C
7.86
6.14
Cdh Tj = +12 °C
0.940
0.960
Pdh Tj = Tbiv
12.33 kW
12.58 kW
COP Tj = Tbiv
2.81
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.33 kW
12.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2781 kWh
3694 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
131 %
Prated
12.50 kW
12.50 kW
SCOP
4.19
3.36
Tbiv
-14 °C
-14 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.36 kW
7.42 kW
COP Tj = -7°C
3.60
2.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.28 kW
4.66 kW
COP Tj = +2°C
5.07
4.04
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
3.56 kW
3.40 kW
COP Tj = +7°C
6.61
5.21
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.08 kW
2.99 kW
COP Tj = 12°C
7.12
5.80
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
9.77 kW
9.31 kW
COP Tj = Tbiv
2.77
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.28 kW
6.83 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.22 kW
5.67 kW
Annual energy consumption Qhe
7347 kWh
9176 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.50
9.04
COP Tj = -15°C (if TOL<-20°C)
2.72
2.18
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
149 %
Prated
12.50 kW
12.50 kW
SCOP
4.83
3.79
Tbiv
-10 °C
-9 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.03 kW
11.06 kW
COP Tj = -7°C
2.70
2.24
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
6.53 kW
6.39 kW
COP Tj = +2°C
4.83
3.74
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.29 kW
4.12 kW
COP Tj = +7°C
6.71
5.13
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
3.23 kW
3.15 kW
COP Tj = 12°C
8.16
6.31
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
12.82 kW
11.65 kW
COP Tj = Tbiv
2.47
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.82 kW
11.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.47
1.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
26 W
26 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.14 kW
Annual energy consumption Qhe
5342 kWh
6818 kWh