Certificate holders

Subtype

Buderus Logatherm WLW166i MBB-4/6/7 AR

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W1239
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus Logatherm WLW166i MBB-4/6/7 AR
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,130 kg

Certification Date
25.03.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland Energy GmbH, DE
Generate PDF Export model CSV
  • Number of models 18

Models

WLW166i-4 MBB AR T180
Configure model
Model name
WLW166i-4 MBB AR T180
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.4 kW

4.09 kW

El input

0.68 kW

1.47 kW

COP

4.99

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

160 %

Prated

4 kW

4 kW

SCOP

6.04

4.08

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.9 kW

4 kW

COP Tj = +2°C

4.18

2.64

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

2.7 kW

2.4 kW

COP Tj = +7°C

5.62

3.56

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

1.7 kW

2.1 kW

COP Tj = 12°C

7.2

5.18

Cdh Tj = +12 °C

0.93

0.96

Pdh Tj = Tbiv

3.9 kW

4 kW

COP Tj = Tbiv

4.18

2.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.9 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.18

2.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

885 kWh

1309 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

122 %

Prated

4 kW

4 kW

SCOP

4.26

3.13

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.3 kW

2.3 kW

COP Tj = -7°C

3.64

2.64

Cdh Tj = -7 °C

0.97

0.98

Pdh Tj = +2°C

1.9 kW

2.1 kW

COP Tj = +2°C

5.08

3.71

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2 kW

2.1 kW

COP Tj = +7°C

6.18

4.66

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.1

5.6

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

3.5 kW

3.5 kW

COP Tj = Tbiv

2.63

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.96 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.61

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1 kW

1.1 kW

Annual energy consumption Qhe

2316 kWh

3147 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.2

3.2

COP Tj = -15°C (if TOL<-20°C)

2.83

2.07

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

4.00 kW

4.00 kW

SCOP

4.99

3.60

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.40 kW

3.60 kW

COP Tj = -7°C

3.22

2.38

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

2.40 kW

2.20 kW

COP Tj = +2°C

5.00

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

2.00 kW

2.10 kW

COP Tj = +7°C

6.25

4.51

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.70 kW

2.20 kW

COP Tj = 12°C

7.67

5.92

Cdh Tj = +12 °C

0.9

1

Pdh Tj = Tbiv

4.30 kW

4.40 kW

COP Tj = Tbiv

2.98

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1699 kWh

2298 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

174 %

COP

4.10

Heating up time

2:30 h:min

Standby power input

30.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

240 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.77

Heating up time

2:29 h:min

Standby power input

75.6 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

2:36 h:min

Standby power input

33.2 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

253 l

WLW166i-6 MBB AR T180
Configure model
Model name
WLW166i-6 MBB AR T180
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.01 kW

5.6 kW

El input

1.04 kW

1.96 kW

COP

4.83

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255 %

172 %

Prated

6 kW

6 kW

SCOP

6.45

4.38

Tbiv

3 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.6 kW

6.6 kW

COP Tj = +2°C

3.63

2.5

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.9 kW

3.9 kW

COP Tj = +7°C

5.64

3.73

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

1.8 kW

2.1 kW

COP Tj = 12°C

8.22

5.65

Cdh Tj = +12 °C

0.92

0.96

Pdh Tj = Tbiv

5.8 kW

6.6 kW

COP Tj = Tbiv

3.8

2.5

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.62 kW

6.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.63

2.5

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

1244 kWh

1889 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

129 %

Prated

6 kW

6 kW

SCOP

4.37

3.3

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.6 kW

3.6 kW

COP Tj = -7°C

3.64

2.74

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

2 kW

2.2 kW

COP Tj = +2°C

5.29

4

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2 kW

2.1 kW

COP Tj = +7°C

6.57

4.95

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.48

5.83

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

5.1 kW

5 kW

COP Tj = Tbiv

2.5

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.7 kW

2 kW

Annual energy consumption Qhe

3386 kWh

4476 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.8

5

COP Tj = -15°C (if TOL<-20°C)

2.7

2.04

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

143 %

Prated

6.00 kW

6.00 kW

SCOP

4.98

3.64

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.50 kW

COP Tj = -7°C

3.20

2.28

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.10 kW

3.10 kW

COP Tj = +2°C

4.85

3.56

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.00 kW

2.10 kW

COP Tj = +7°C

6.41

4.73

Cdh Tj = +7 °C

0.900

1.000

Pdh Tj = 12°C

1.80 kW

2.20 kW

COP Tj = 12°C

8.00

5.94

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

6.00 kW

5.80 kW

COP Tj = Tbiv

2.77

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.40 kW

Annual energy consumption Qhe

2490 kWh

3406 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

174 %

COP

4.10

Heating up time

2:30 h:min

Standby power input

30.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

240 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.77

Heating up time

2:29 h:min

Standby power input

75.6 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

2:36 h:min

Standby power input

33.2 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

253 l

WLW166i-7 MBB AR T180
Configure model
Model name
WLW166i-7 MBB AR T180
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.28 kW

6.33 kW

El input

1.42 kW

2.29 kW

COP

4.41

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

251 %

176 %

Prated

8.00 kW

8.00 kW

SCOP

6.34

4.47

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.60 kW

7.90 kW

COP Tj = +2°C

2.80

2.25

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

5.20 kW

5.30 kW

COP Tj = +7°C

5.51

3.73

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.40 kW

2.10 kW

COP Tj = 12°C

8.33

5.94

Cdh Tj = +12 °C

0.94

0.95

Pdh Tj = Tbiv

7.60 kW

7.90 kW

COP Tj = Tbiv

2.80

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1685 kWh

2390 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

128 %

Prated

8 kW

8 kW

SCOP

4.27

3.29

Tbiv

-15 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.7 kW

4.8 kW

COP Tj = -7°C

3.52

2.7

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.8 kW

3 kW

COP Tj = +2°C

5.27

4.04

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.1 kW

2.2 kW

COP Tj = +7°C

6.98

5.25

Cdh Tj = +7 °C

0.94

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.86

6.08

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

6.4 kW

6.2 kW

COP Tj = Tbiv

2.49

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.1

1.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.8 kW

3.1 kW

Annual energy consumption Qhe

4617 kWh

6002 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.4

6.1

COP Tj = -15°C (if TOL<-20°C)

2.49

1.97

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

144 %

Prated

8.00 kW

8.00 kW

SCOP

4.96

3.67

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.70 kW

6.80 kW

COP Tj = -7°C

3.03

2.24

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

2.90 kW

2.60 kW

COP Tj = +7°C

6.69

4.84

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.70 kW

2.20 kW

COP Tj = 12°C

8.01

6.27

Cdh Tj = +12 °C

0.9

1

Pdh Tj = Tbiv

7.70 kW

6.80 kW

COP Tj = Tbiv

2.76

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.30 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

1.30 kW

Annual energy consumption Qhe

3334 kWh

4504 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

174 %

COP

4.10

Heating up time

2:30 h:min

Standby power input

30.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

240 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.77

Heating up time

2:29 h:min

Standby power input

75.6 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

2:36 h:min

Standby power input

33.2 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

253 l

WLW166i-4 MBB AR T180 HK
Configure model
Model name
WLW166i-4 MBB AR T180 HK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.4 kW

4.09 kW

El input

0.68 kW

1.47 kW

COP

4.99

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

160 %

Prated

4 kW

4 kW

SCOP

6.04

4.08

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.9 kW

4 kW

COP Tj = +2°C

4.18

2.64

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

2.7 kW

2.4 kW

COP Tj = +7°C

5.62

3.56

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

1.7 kW

2.1 kW

COP Tj = 12°C

7.2

5.18

Cdh Tj = +12 °C

0.93

0.96

Pdh Tj = Tbiv

3.9 kW

4 kW

COP Tj = Tbiv

4.18

2.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.9 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.18

2.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

885 kWh

1309 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

122 %

Prated

4 kW

4 kW

SCOP

4.26

3.13

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.3 kW

2.3 kW

COP Tj = -7°C

3.64

2.64

Cdh Tj = -7 °C

0.97

0.98

Pdh Tj = +2°C

1.9 kW

2.1 kW

COP Tj = +2°C

5.08

3.71

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2 kW

2.1 kW

COP Tj = +7°C

6.18

4.66

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.1

5.6

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

3.5 kW

3.5 kW

COP Tj = Tbiv

2.63

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.96 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.61

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1 kW

1.1 kW

Annual energy consumption Qhe

2316 kWh

3147 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.2

3.2

COP Tj = -15°C (if TOL<-20°C)

2.83

2.07

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

4.00 kW

4.00 kW

SCOP

4.99

3.60

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.40 kW

3.60 kW

COP Tj = -7°C

3.22

2.38

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

2.40 kW

2.20 kW

COP Tj = +2°C

5.00

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

2.00 kW

2.10 kW

COP Tj = +7°C

6.25

4.51

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.70 kW

2.20 kW

COP Tj = 12°C

7.67

5.92

Cdh Tj = +12 °C

0.9

1

Pdh Tj = Tbiv

4.30 kW

4.40 kW

COP Tj = Tbiv

2.98

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1699 kWh

2298 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

174 %

COP

4.10

Heating up time

2:30 h:min

Standby power input

30.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

240 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.77

Heating up time

2:29 h:min

Standby power input

75.6 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

2:36 h:min

Standby power input

33.2 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

253 l

WLW166i-6 MBB AR T180 HK
Configure model
Model name
WLW166i-6 MBB AR T180 HK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.01 kW

5.6 kW

El input

1.04 kW

1.96 kW

COP

4.83

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255 %

172 %

Prated

6 kW

6 kW

SCOP

6.45

4.38

Tbiv

3 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.6 kW

6.6 kW

COP Tj = +2°C

3.63

2.5

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.9 kW

3.9 kW

COP Tj = +7°C

5.64

3.73

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

1.8 kW

2.1 kW

COP Tj = 12°C

8.22

5.65

Cdh Tj = +12 °C

0.92

0.96

Pdh Tj = Tbiv

5.8 kW

6.6 kW

COP Tj = Tbiv

3.8

2.5

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.62 kW

6.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.63

2.5

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

1244 kWh

1889 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

129 %

Prated

6 kW

6 kW

SCOP

4.37

3.3

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.6 kW

3.6 kW

COP Tj = -7°C

3.64

2.74

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

2 kW

2.2 kW

COP Tj = +2°C

5.29

4

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2 kW

2.1 kW

COP Tj = +7°C

6.57

4.95

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.48

5.83

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

5.1 kW

5 kW

COP Tj = Tbiv

2.5

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.7 kW

2 kW

Annual energy consumption Qhe

3386 kWh

4476 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.8

5

COP Tj = -15°C (if TOL<-20°C)

2.7

2.04

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

143 %

Prated

6.00 kW

6.00 kW

SCOP

4.98

3.64

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.50 kW

COP Tj = -7°C

3.20

2.28

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.10 kW

3.10 kW

COP Tj = +2°C

4.85

3.56

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.00 kW

2.10 kW

COP Tj = +7°C

6.41

4.73

Cdh Tj = +7 °C

0.900

1.000

Pdh Tj = 12°C

1.80 kW

2.20 kW

COP Tj = 12°C

8.00

5.94

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

6.00 kW

5.80 kW

COP Tj = Tbiv

2.77

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.40 kW

Annual energy consumption Qhe

2490 kWh

3406 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

174 %

COP

4.10

Heating up time

2:30 h:min

Standby power input

30.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

240 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.77

Heating up time

2:29 h:min

Standby power input

75.6 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

2:36 h:min

Standby power input

33.2 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

253 l

WLW166i-7 MBB AR T180 HK
Configure model
Model name
WLW166i-7 MBB AR T180 HK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.28 kW

6.33 kW

El input

1.42 kW

2.29 kW

COP

4.41

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

251 %

176 %

Prated

8.00 kW

8.00 kW

SCOP

6.34

4.47

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.60 kW

7.90 kW

COP Tj = +2°C

2.80

2.25

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

5.20 kW

5.30 kW

COP Tj = +7°C

5.51

3.73

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.40 kW

2.10 kW

COP Tj = 12°C

8.33

5.94

Cdh Tj = +12 °C

0.94

0.95

Pdh Tj = Tbiv

7.60 kW

7.90 kW

COP Tj = Tbiv

2.80

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1685 kWh

2390 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

128 %

Prated

8 kW

8 kW

SCOP

4.27

3.29

Tbiv

-15 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.7 kW

4.8 kW

COP Tj = -7°C

3.52

2.7

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.8 kW

3 kW

COP Tj = +2°C

5.27

4.04

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.1 kW

2.2 kW

COP Tj = +7°C

6.98

5.25

Cdh Tj = +7 °C

0.94

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.86

6.08

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

6.4 kW

6.2 kW

COP Tj = Tbiv

2.49

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.1

1.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.8 kW

3.1 kW

Annual energy consumption Qhe

4617 kWh

6002 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.4

6.1

COP Tj = -15°C (if TOL<-20°C)

2.49

1.97

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

144 %

Prated

8.00 kW

8.00 kW

SCOP

4.96

3.67

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.70 kW

6.80 kW

COP Tj = -7°C

3.03

2.24

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

2.90 kW

2.60 kW

COP Tj = +7°C

6.69

4.84

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.70 kW

2.20 kW

COP Tj = 12°C

8.01

6.27

Cdh Tj = +12 °C

0.9

1

Pdh Tj = Tbiv

7.70 kW

6.80 kW

COP Tj = Tbiv

2.76

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.30 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

1.30 kW

Annual energy consumption Qhe

3334 kWh

4504 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

174 %

COP

4.10

Heating up time

2:30 h:min

Standby power input

30.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

240 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.77

Heating up time

2:29 h:min

Standby power input

75.6 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

2:36 h:min

Standby power input

33.2 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

253 l

WLW176i.2-4 MBB AR E
Configure model
Model name
WLW176i.2-4 MBB AR E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.4 kW

4.09 kW

El input

0.68 kW

1.47 kW

COP

4.99

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

160 %

Prated

4 kW

4 kW

SCOP

6.04

4.08

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.9 kW

4 kW

COP Tj = +2°C

4.18

2.64

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

2.7 kW

2.4 kW

COP Tj = +7°C

5.62

3.56

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

1.7 kW

2.1 kW

COP Tj = 12°C

7.2

5.18

Cdh Tj = +12 °C

0.93

0.96

Pdh Tj = Tbiv

3.9 kW

4 kW

COP Tj = Tbiv

4.18

2.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.9 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.18

2.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

885 kWh

1309 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

122 %

Prated

4 kW

4 kW

SCOP

4.26

3.13

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.3 kW

2.3 kW

COP Tj = -7°C

3.64

2.64

Cdh Tj = -7 °C

0.97

0.98

Pdh Tj = +2°C

1.9 kW

2.1 kW

COP Tj = +2°C

5.08

3.71

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2 kW

2.1 kW

COP Tj = +7°C

6.18

4.66

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.1

5.6

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

3.5 kW

3.5 kW

COP Tj = Tbiv

2.63

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.96 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.61

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1 kW

1.1 kW

Annual energy consumption Qhe

2316 kWh

3147 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.2

3.2

COP Tj = -15°C (if TOL<-20°C)

2.83

2.07

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

4.00 kW

4.00 kW

SCOP

4.99

3.60

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.40 kW

3.60 kW

COP Tj = -7°C

3.22

2.38

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

2.40 kW

2.20 kW

COP Tj = +2°C

5.00

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

2.00 kW

2.10 kW

COP Tj = +7°C

6.25

4.51

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.70 kW

2.20 kW

COP Tj = 12°C

7.67

5.92

Cdh Tj = +12 °C

0.9

1

Pdh Tj = Tbiv

4.30 kW

4.40 kW

COP Tj = Tbiv

2.98

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1699 kWh

2298 kWh

WLW176i.2-6 MBB AR E
Configure model
Model name
WLW176i.2-6 MBB AR E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.01 kW

5.6 kW

El input

1.04 kW

1.96 kW

COP

4.83

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255 %

172 %

Prated

6 kW

6 kW

SCOP

6.45

4.38

Tbiv

3 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.6 kW

6.6 kW

COP Tj = +2°C

3.63

2.5

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.9 kW

3.9 kW

COP Tj = +7°C

5.64

3.73

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

1.8 kW

2.1 kW

COP Tj = 12°C

8.22

5.65

Cdh Tj = +12 °C

0.92

0.96

Pdh Tj = Tbiv

5.8 kW

6.6 kW

COP Tj = Tbiv

3.8

2.5

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.62 kW

6.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.63

2.5

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

1244 kWh

1889 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

129 %

Prated

6 kW

6 kW

SCOP

4.37

3.3

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.6 kW

3.6 kW

COP Tj = -7°C

3.64

2.74

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

2 kW

2.2 kW

COP Tj = +2°C

5.29

4

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2 kW

2.1 kW

COP Tj = +7°C

6.57

4.95

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.48

5.83

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

5.1 kW

5 kW

COP Tj = Tbiv

2.5

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.7 kW

2 kW

Annual energy consumption Qhe

3386 kWh

4476 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.8

5

COP Tj = -15°C (if TOL<-20°C)

2.7

2.04

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

143 %

Prated

6.00 kW

6.00 kW

SCOP

4.98

3.64

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.50 kW

COP Tj = -7°C

3.20

2.28

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.10 kW

3.10 kW

COP Tj = +2°C

4.85

3.56

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.00 kW

2.10 kW

COP Tj = +7°C

6.41

4.73

Cdh Tj = +7 °C

0.900

1.000

Pdh Tj = 12°C

1.80 kW

2.20 kW

COP Tj = 12°C

8.00

5.94

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

6.00 kW

5.80 kW

COP Tj = Tbiv

2.77

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.40 kW

Annual energy consumption Qhe

2490 kWh

3406 kWh

WLW176i.2-7 MBB AR E
Configure model
Model name
WLW176i.2-7 MBB AR E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.28 kW

6.33 kW

El input

1.42 kW

2.29 kW

COP

4.41

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

251 %

176 %

Prated

8.00 kW

8.00 kW

SCOP

6.34

4.47

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.60 kW

7.90 kW

COP Tj = +2°C

2.80

2.25

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

5.20 kW

5.30 kW

COP Tj = +7°C

5.51

3.73

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.40 kW

2.10 kW

COP Tj = 12°C

8.33

5.94

Cdh Tj = +12 °C

0.94

0.95

Pdh Tj = Tbiv

7.60 kW

7.90 kW

COP Tj = Tbiv

2.80

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1685 kWh

2390 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

128 %

Prated

8 kW

8 kW

SCOP

4.27

3.29

Tbiv

-15 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.7 kW

4.8 kW

COP Tj = -7°C

3.52

2.7

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.8 kW

3 kW

COP Tj = +2°C

5.27

4.04

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.1 kW

2.2 kW

COP Tj = +7°C

6.98

5.25

Cdh Tj = +7 °C

0.94

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.86

6.08

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

6.4 kW

6.2 kW

COP Tj = Tbiv

2.49

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.1

1.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.8 kW

3.1 kW

Annual energy consumption Qhe

4617 kWh

6002 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.4

6.1

COP Tj = -15°C (if TOL<-20°C)

2.49

1.97

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

144 %

Prated

8.00 kW

8.00 kW

SCOP

4.96

3.67

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.70 kW

6.80 kW

COP Tj = -7°C

3.03

2.24

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

2.90 kW

2.60 kW

COP Tj = +7°C

6.69

4.84

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.70 kW

2.20 kW

COP Tj = 12°C

8.01

6.27

Cdh Tj = +12 °C

0.9

1

Pdh Tj = Tbiv

7.70 kW

6.80 kW

COP Tj = Tbiv

2.76

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.30 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

1.30 kW

Annual energy consumption Qhe

3334 kWh

4504 kWh

WLW-4 FMBB AR WPM400 S
Configure model
Model name
WLW-4 FMBB AR WPM400 S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.4 kW

4.09 kW

El input

0.68 kW

1.47 kW

COP

4.99

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

160 %

Prated

4 kW

4 kW

SCOP

6.04

4.08

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.9 kW

4 kW

COP Tj = +2°C

4.18

2.64

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

2.7 kW

2.4 kW

COP Tj = +7°C

5.62

3.56

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

1.7 kW

2.1 kW

COP Tj = 12°C

7.2

5.18

Cdh Tj = +12 °C

0.93

0.96

Pdh Tj = Tbiv

3.9 kW

4 kW

COP Tj = Tbiv

4.18

2.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.9 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.18

2.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

885 kWh

1309 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

122 %

Prated

4 kW

4 kW

SCOP

4.26

3.13

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.3 kW

2.3 kW

COP Tj = -7°C

3.64

2.64

Cdh Tj = -7 °C

0.97

0.98

Pdh Tj = +2°C

1.9 kW

2.1 kW

COP Tj = +2°C

5.08

3.71

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2 kW

2.1 kW

COP Tj = +7°C

6.18

4.66

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.1

5.6

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

3.5 kW

3.5 kW

COP Tj = Tbiv

2.63

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.96 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.61

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1 kW

1.1 kW

Annual energy consumption Qhe

2316 kWh

3147 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.2

3.2

COP Tj = -15°C (if TOL<-20°C)

2.83

2.07

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

141 %

Prated

4.00 kW

4.00 kW

SCOP

4.99

3.60

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.40 kW

3.60 kW

COP Tj = -7°C

3.22

2.38

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

2.40 kW

2.20 kW

COP Tj = +2°C

5.00

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

2.00 kW

2.10 kW

COP Tj = +7°C

6.25

4.51

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.70 kW

2.20 kW

COP Tj = 12°C

7.67

5.92

Cdh Tj = +12 °C

0.9

1

Pdh Tj = Tbiv

4.30 kW

4.40 kW

COP Tj = Tbiv

2.98

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1699 kWh

2298 kWh

WLW-6 FMBB AR WPM400 S
Configure model
Model name
WLW-6 FMBB AR WPM400 S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.01 kW

5.6 kW

El input

1.04 kW

1.96 kW

COP

4.83

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255 %

172 %

Prated

6 kW

6 kW

SCOP

6.45

4.38

Tbiv

3 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.6 kW

6.6 kW

COP Tj = +2°C

3.63

2.5

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.9 kW

3.9 kW

COP Tj = +7°C

5.64

3.73

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

1.8 kW

2.1 kW

COP Tj = 12°C

8.22

5.65

Cdh Tj = +12 °C

0.92

0.96

Pdh Tj = Tbiv

5.8 kW

6.6 kW

COP Tj = Tbiv

3.8

2.5

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.62 kW

6.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.63

2.5

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

1244 kWh

1889 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

129 %

Prated

6 kW

6 kW

SCOP

4.37

3.3

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.6 kW

3.6 kW

COP Tj = -7°C

3.64

2.74

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

2 kW

2.2 kW

COP Tj = +2°C

5.29

4

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2 kW

2.1 kW

COP Tj = +7°C

6.57

4.95

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.48

5.83

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

5.1 kW

5 kW

COP Tj = Tbiv

2.5

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.7 kW

2 kW

Annual energy consumption Qhe

3386 kWh

4476 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.8

5

COP Tj = -15°C (if TOL<-20°C)

2.7

2.04

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

143 %

Prated

6.00 kW

6.00 kW

SCOP

4.98

3.64

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.50 kW

COP Tj = -7°C

3.20

2.28

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.10 kW

3.10 kW

COP Tj = +2°C

4.85

3.56

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.00 kW

2.10 kW

COP Tj = +7°C

6.41

4.73

Cdh Tj = +7 °C

0.900

1.000

Pdh Tj = 12°C

1.80 kW

2.20 kW

COP Tj = 12°C

8.00

5.94

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

6.00 kW

5.80 kW

COP Tj = Tbiv

2.77

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.40 kW

Annual energy consumption Qhe

2490 kWh

3406 kWh

WLW-7 FMBB AR WPM400 S
Configure model
Model name
WLW-7 FMBB AR WPM400 S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.28 kW

6.33 kW

El input

1.42 kW

2.29 kW

COP

4.41

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

251 %

176 %

Prated

8.00 kW

8.00 kW

SCOP

6.34

4.47

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.60 kW

7.90 kW

COP Tj = +2°C

2.80

2.25

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

5.20 kW

5.30 kW

COP Tj = +7°C

5.51

3.73

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.40 kW

2.10 kW

COP Tj = 12°C

8.33

5.94

Cdh Tj = +12 °C

0.94

0.95

Pdh Tj = Tbiv

7.60 kW

7.90 kW

COP Tj = Tbiv

2.80

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1685 kWh

2390 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

128 %

Prated

8 kW

8 kW

SCOP

4.27

3.29

Tbiv

-15 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.7 kW

4.8 kW

COP Tj = -7°C

3.52

2.7

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.8 kW

3 kW

COP Tj = +2°C

5.27

4.04

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.1 kW

2.2 kW

COP Tj = +7°C

6.98

5.25

Cdh Tj = +7 °C

0.94

0.96

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

7.86

6.08

Cdh Tj = +12 °C

0.93

0.94

Pdh Tj = Tbiv

6.4 kW

6.2 kW

COP Tj = Tbiv

2.49

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.1

1.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.8 kW

3.1 kW

Annual energy consumption Qhe

4617 kWh

6002 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.4

6.1

COP Tj = -15°C (if TOL<-20°C)

2.49

1.97

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

144 %

Prated

8.00 kW

8.00 kW

SCOP

4.96

3.67

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.70 kW

6.80 kW

COP Tj = -7°C

3.03

2.24

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

2.90 kW

2.60 kW

COP Tj = +7°C

6.69

4.84

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.70 kW

2.20 kW

COP Tj = 12°C

8.01

6.27

Cdh Tj = +12 °C

0.9

1

Pdh Tj = Tbiv

7.70 kW

6.80 kW

COP Tj = Tbiv

2.76

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.30 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

16 W

16 W

PSB

15 W

15 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

1.30 kW

Annual energy consumption Qhe

3334 kWh

4504 kWh

WLW-4 MBB A H
Configure model
Model name
WLW-4 MBB A H
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.40 kW

4.09 kW

El input

0.70 kW

1.49 kW

COP

4.83

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

145 %

Prated

4.00 kW

4.00 kW

SCOP

5.29

3.70

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.90 kW

3.96 kW

COP Tj = +2°C

4.08

2.61

Cdh Tj = +2 °C

0.960

0.980

Pdh Tj = +7°C

2.70 kW

2.37 kW

COP Tj = +7°C

5.38

3.45

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.67 kW

2.06 kW

COP Tj = 12°C

6.62

4.92

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

3.90 kW

3.96 kW

COP Tj = Tbiv

4.08

2.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.90 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.08

2.61

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.960

0.980

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1011 kWh

1446 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

116 %

Prated

4.00 kW

4.00 kW

SCOP

3.99

2.98

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.34 kW

2.29 kW

COP Tj = -7°C

3.52

2.57

Cdh Tj = -7 °C

0.950

0.960

Pdh Tj = +2°C

1.91 kW

2.14 kW

COP Tj = +2°C

4.82

3.58

Cdh Tj = +2 °C

0.910

0.940

Pdh Tj = +7°C

1.96 kW

2.08 kW

COP Tj = +7°C

5.80

4.46

Cdh Tj = +7 °C

0.900

0.930

Pdh Tj = 12°C

1.66 kW

1.55 kW

COP Tj = 12°C

6.53

5.21

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.51 kW

3.48 kW

COP Tj = Tbiv

2.59

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.96 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.14 kW

Annual energy consumption Qhe

2474 kWh

3309 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.25

3.19

COP Tj = -15°C (if TOL<-20°C)

2.77

2.05

Cdh Tj = -15 °C

0.970

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

133 %

Prated

4.10 kW

4.00 kW

SCOP

4.65

3.39

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.37 kW

3.63 kW

COP Tj = -7°C

3.16

2.35

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.42 kW

2.15 kW

COP Tj = +2°C

4.84

3.41

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

2.02 kW

2.14 kW

COP Tj = +7°C

5.92

4.34

Cdh Tj = +7 °C

0.910

0.930

Pdh Tj = 12°C

1.72 kW

2.19 kW

COP Tj = 12°C

7.11

5.66

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

4.30 kW

4.38 kW

COP Tj = Tbiv

2.94

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

4.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.94

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.980

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

33 W

33 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1822 kWh

2439 kWh

WLW-6 MBB A H
Configure model
Model name
WLW-6 MBB A H
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.01 kW

5.60 kW

El input

1.07 kW

1.98 kW

COP

4.71

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

229 %

160 %

Prated

6.00 kW

6.20 kW

SCOP

5.80

4.09

Tbiv

3 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.62 kW

6.58 kW

COP Tj = +2°C

3.56

2.48

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.92 kW

3.89 kW

COP Tj = +7°C

5.46

3.65

Cdh Tj = +7 °C

0.950

0.970

Pdh Tj = 12°C

1.77 kW

2.11 kW

COP Tj = 12°C

7.50

5.36

Cdh Tj = +12 °C

0.900

0.910

Pdh Tj = Tbiv

5.82 kW

6.58 kW

COP Tj = Tbiv

3.72

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.62 kW

6.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.56

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.38 kW

0.00 kW

Annual energy consumption Qhe

1382 kWh

2027 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

124 %

Prated

6.00 kW

6.00 kW

SCOP

4.16

3.19

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.58 kW

COP Tj = -7°C

3.56

2.69

Cdh Tj = -7 °C

0.970

0.970

Pdh Tj = +2°C

2.00 kW

2.19 kW

COP Tj = +2°C

5.01

3.86

Cdh Tj = +2 °C

0.910

0.940

Pdh Tj = +7°C

2.01 kW

2.12 kW

COP Tj = +7°C

6.16

4.72

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

1.70 kW

1.57 kW

COP Tj = 12°C

6.86

5.42

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.07 kW

5.02 kW

COP Tj = Tbiv

2.47

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.35 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.65 kW

2.04 kW

Annual energy consumption Qhe

3559 kWh

4642 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.83

5.02

COP Tj = -15°C (if TOL<-20°C)

2.66

2.03

Cdh Tj = -15 °C

0.980

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

136 %

Prated

6.00 kW

6.00 kW

SCOP

4.69

3.49

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.01 kW

5.48 kW

COP Tj = -7°C

3.15

2.26

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.12 kW

3.10 kW

COP Tj = +2°C

4.69

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.99 kW

2.09 kW

COP Tj = +7°C

6.01

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

1.76 kW

2.16 kW

COP Tj = 12°C

7.32

5.62

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.04 kW

5.75 kW

COP Tj = Tbiv

2.73

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.04 kW

5.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.43 kW

Annual energy consumption Qhe

2643 kWh

3556 kWh

WLW-7 MBB A H
Configure model
Model name
WLW-7 MBB A H
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.29 kW

6.33 kW

El input

1.46 kW

2.31 kW

COP

4.31

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

166 %

Prated

8.20 kW

8.00 kW

SCOP

5.85

4.22

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.62 kW

7.88 kW

COP Tj = +2°C

2.76

2.24

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.22 kW

5.30 kW

COP Tj = +7°C

5.35

3.68

Cdh Tj = +7 °C

0.960

0.980

Pdh Tj = 12°C

2.39 kW

2.15 kW

COP Tj = 12°C

7.77

5.62

Cdh Tj = +12 °C

0.900

0.910

Pdh Tj = Tbiv

7.62 kW

7.88 kW

COP Tj = Tbiv

2.76

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.62 kW

7.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1873 kWh

2533 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

125 %

Prated

8.00 kW

8.00 kW

SCOP

4.11

3.20

Tbiv

-15 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.75 kW

4.83 kW

COP Tj = -7°C

3.46

2.67

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.85 kW

2.98 kW

COP Tj = +2°C

5.07

3.93

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

2.05 kW

2.16 kW

COP Tj = +7°C

6.53

5.00

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

1.74 kW

1.59 kW

COP Tj = 12°C

7.19

5.64

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.42 kW

6.23 kW

COP Tj = Tbiv

2.46

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.75 kW

3.15 kW

Annual energy consumption Qhe

4793 kWh

6169 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.42

6.06

COP Tj = -15°C (if TOL<-20°C)

2.46

1.96

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

139 %

Prated

8.00 kW

8.00 kW

SCOP

4.75

3.55

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.66 kW

6.84 kW

COP Tj = -7°C

2.98

2.23

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

4.15 kW

4.35 kW

COP Tj = +2°C

4.71

3.53

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.87 kW

2.62 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.920

0.940

Pdh Tj = 12°C

1.73 kW

2.21 kW

COP Tj = 12°C

7.37

5.95

Cdh Tj = +12 °C

0.900

0.910

Pdh Tj = Tbiv

7.72 kW

6.84 kW

COP Tj = Tbiv

2.72

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.34 kW

6.73 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.66 kW

1.27 kW

Annual energy consumption Qhe

3477 kWh

4654 kWh

WLW-4 MBB A H GBH172i
Configure model
Model name
WLW-4 MBB A H GBH172i
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.40 kW

4.09 kW

El input

0.70 kW

1.49 kW

COP

4.83

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

145 %

Prated

4.00 kW

4.00 kW

SCOP

5.29

3.70

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.90 kW

3.96 kW

COP Tj = +2°C

4.08

2.61

Cdh Tj = +2 °C

0.960

0.980

Pdh Tj = +7°C

2.70 kW

2.37 kW

COP Tj = +7°C

5.38

3.45

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.67 kW

2.06 kW

COP Tj = 12°C

6.62

4.92

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

3.90 kW

3.96 kW

COP Tj = Tbiv

4.08

2.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.90 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.08

2.61

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.960

0.980

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1011 kWh

1446 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

116 %

Prated

4.00 kW

4.00 kW

SCOP

3.99

2.98

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.34 kW

2.29 kW

COP Tj = -7°C

3.52

2.57

Cdh Tj = -7 °C

0.950

0.960

Pdh Tj = +2°C

1.91 kW

2.14 kW

COP Tj = +2°C

4.82

3.58

Cdh Tj = +2 °C

0.910

0.940

Pdh Tj = +7°C

1.96 kW

2.08 kW

COP Tj = +7°C

5.80

4.46

Cdh Tj = +7 °C

0.900

0.930

Pdh Tj = 12°C

1.66 kW

1.55 kW

COP Tj = 12°C

6.53

5.21

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.51 kW

3.48 kW

COP Tj = Tbiv

2.59

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.96 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.14 kW

Annual energy consumption Qhe

2474 kWh

3309 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.25

3.19

COP Tj = -15°C (if TOL<-20°C)

2.77

2.05

Cdh Tj = -15 °C

0.970

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

133 %

Prated

4.10 kW

4.00 kW

SCOP

4.65

3.39

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.37 kW

3.63 kW

COP Tj = -7°C

3.16

2.35

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.42 kW

2.15 kW

COP Tj = +2°C

4.84

3.41

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

2.02 kW

2.14 kW

COP Tj = +7°C

5.92

4.34

Cdh Tj = +7 °C

0.910

0.930

Pdh Tj = 12°C

1.72 kW

2.19 kW

COP Tj = 12°C

7.11

5.66

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

4.30 kW

4.38 kW

COP Tj = Tbiv

2.94

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

4.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.94

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.980

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

33 W

33 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1822 kWh

2439 kWh

WLW-6 MBB A H GBH172i
Configure model
Model name
WLW-6 MBB A H GBH172i
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.01 kW

5.60 kW

El input

1.07 kW

1.98 kW

COP

4.71

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

229 %

160 %

Prated

6.00 kW

6.20 kW

SCOP

5.80

4.09

Tbiv

3 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.62 kW

6.58 kW

COP Tj = +2°C

3.56

2.48

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.92 kW

3.89 kW

COP Tj = +7°C

5.46

3.65

Cdh Tj = +7 °C

0.950

0.970

Pdh Tj = 12°C

1.77 kW

2.11 kW

COP Tj = 12°C

7.50

5.36

Cdh Tj = +12 °C

0.900

0.910

Pdh Tj = Tbiv

5.82 kW

6.58 kW

COP Tj = Tbiv

3.72

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.62 kW

6.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.56

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.38 kW

0.00 kW

Annual energy consumption Qhe

1382 kWh

2027 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

124 %

Prated

6.00 kW

6.00 kW

SCOP

4.16

3.19

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.58 kW

COP Tj = -7°C

3.56

2.69

Cdh Tj = -7 °C

0.970

0.970

Pdh Tj = +2°C

2.00 kW

2.19 kW

COP Tj = +2°C

5.01

3.86

Cdh Tj = +2 °C

0.910

0.940

Pdh Tj = +7°C

2.01 kW

2.12 kW

COP Tj = +7°C

6.16

4.72

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

1.70 kW

1.57 kW

COP Tj = 12°C

6.86

5.42

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.07 kW

5.02 kW

COP Tj = Tbiv

2.47

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.35 kW

3.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.65 kW

2.04 kW

Annual energy consumption Qhe

3559 kWh

4642 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.83

5.02

COP Tj = -15°C (if TOL<-20°C)

2.66

2.03

Cdh Tj = -15 °C

0.980

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

136 %

Prated

6.00 kW

6.00 kW

SCOP

4.69

3.49

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.01 kW

5.48 kW

COP Tj = -7°C

3.15

2.26

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.12 kW

3.10 kW

COP Tj = +2°C

4.69

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.99 kW

2.09 kW

COP Tj = +7°C

6.01

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

1.76 kW

2.16 kW

COP Tj = 12°C

7.32

5.62

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.04 kW

5.75 kW

COP Tj = Tbiv

2.73

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.04 kW

5.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.43 kW

Annual energy consumption Qhe

2643 kWh

3556 kWh

WLW-7 MBB A H GBH172i
Configure model
Model name
WLW-7 MBB A H GBH172i
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.29 kW

6.33 kW

El input

1.46 kW

2.31 kW

COP

4.31

2.74

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

166 %

Prated

8.20 kW

8.00 kW

SCOP

5.85

4.22

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.62 kW

7.88 kW

COP Tj = +2°C

2.76

2.24

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.22 kW

5.30 kW

COP Tj = +7°C

5.35

3.68

Cdh Tj = +7 °C

0.960

0.980

Pdh Tj = 12°C

2.39 kW

2.15 kW

COP Tj = 12°C

7.77

5.62

Cdh Tj = +12 °C

0.900

0.910

Pdh Tj = Tbiv

7.62 kW

7.88 kW

COP Tj = Tbiv

2.76

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.62 kW

7.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1873 kWh

2533 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

125 %

Prated

8.00 kW

8.00 kW

SCOP

4.11

3.20

Tbiv

-15 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.75 kW

4.83 kW

COP Tj = -7°C

3.46

2.67

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.85 kW

2.98 kW

COP Tj = +2°C

5.07

3.93

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

2.05 kW

2.16 kW

COP Tj = +7°C

6.53

5.00

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

1.74 kW

1.59 kW

COP Tj = 12°C

7.19

5.64

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.42 kW

6.23 kW

COP Tj = Tbiv

2.46

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.75 kW

3.15 kW

Annual energy consumption Qhe

4793 kWh

6169 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.42

6.06

COP Tj = -15°C (if TOL<-20°C)

2.46

1.96

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

139 %

Prated

8.00 kW

8.00 kW

SCOP

4.75

3.55

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.66 kW

6.84 kW

COP Tj = -7°C

2.98

2.23

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

4.15 kW

4.35 kW

COP Tj = +2°C

4.71

3.53

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.87 kW

2.62 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.920

0.940

Pdh Tj = 12°C

1.73 kW

2.21 kW

COP Tj = 12°C

7.37

5.95

Cdh Tj = +12 °C

0.900

0.910

Pdh Tj = Tbiv

7.72 kW

6.84 kW

COP Tj = Tbiv

2.72

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.34 kW

6.73 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

35 W

35 W

PSB

33 W

33 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.66 kW

1.27 kW

Annual energy consumption Qhe

3477 kWh

4654 kWh