Certificate holders

Subtype

IGLU Inuit Mono 12

Certificate Holder
IGLU TECH, UAB
Ukmergės g. 364-6
14188 Vilnius
Lithuania
Registration number
011-1W1336
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
IGLU Inuit Mono 12
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,250 kg

Certification Date
10.09.2026
Testing basis
European KEYMARK Scheme for Heat Pumps rev.15
Testing laboratory
TÜV Rheinland Korea Ltd., KR
Generate PDF Export model CSV
  • Number of models 1

Models

IGLU Inuit Mono 12 MB012INANMITrd/MB012INANMOTrd
Configure model
Model name
IGLU Inuit Mono 12 MB012INANMITrd/MB012INANMOTrd
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

4.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

257 %

180 %

Prated

12.50 kW

12.50 kW

SCOP

6.51

4.58

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.50 kW

12.50 kW

COP Tj = +2°C

3.45

2.40

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.04 kW

8.04 kW

COP Tj = +7°C

5.80

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.30 kW

4.20 kW

COP Tj = 12°C

8.20

6.00

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.50 kW

12.50 kW

COP Tj = Tbiv

3.45

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.50 kW

12.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.45

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2549 kWh

3631 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

12.00 kW

12.00 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.62 kW

COP Tj = -7°C

2.95

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.46 kW

6.46 kW

COP Tj = +2°C

4.83

3.60

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.15 kW

4.20 kW

COP Tj = +7°C

6.50

4.88

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.15 kW

4.20 kW

COP Tj = 12°C

8.00

5.95

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.62 kW

10.62 kW

COP Tj = Tbiv

2.95

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.62 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.50 kW

Annual energy consumption Qhe

5051 kWh

6784 kWh