Certificate holders

Subtype

Air to water heat pump 8K

Certificate Holder
HP+ BV
Nijverheidsstraat 7
3990 Peer
Belgium
Registration number
011-1W1330
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Air to water heat pump 8K
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,050 kg

Certification Date
06.08.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 2

Models

Indoor unit ZY-IU-SOL and outdoor unit HP-OU-08
Configure model
Model name
Indoor unit ZY-IU-SOL and outdoor unit HP-OU-08
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.74 kW

7.51 kW

El input

1.49 kW

2.46 kW

COP

5.20

3.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

Sound power level outdoor

49 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

161 %

Prated

7.63 kW

7.50 kW

SCOP

5.44

4.09

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.67 kW

6.90 kW

COP Tj = -7°C

3.50

2.60

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.06 kW

4.14 kW

COP Tj = +2°C

5.29

3.94

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.04 kW

2.88 kW

COP Tj = +7°C

6.95

5.23

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.59 kW

3.39 kW

COP Tj = 12°C

9.48

7.40

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

7.63 kW

7.50 kW

COP Tj = Tbiv

2.91

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.63 kW

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.91

2.29

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

14 W

14 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2896 kWh

3789 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

140 %

COP

3.49

Heating up time

1:40 h:min

Standby power input

29.0 W

Reference hot water temperature

45.7 °C

Mixed water at 40°C

190 l

Indoor unit CA-IU-AIO and outdoor unit HP-OU-08
Configure model
Model name
Indoor unit CA-IU-AIO and outdoor unit HP-OU-08
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.74 kW

7.51 kW

El input

1.49 kW

2.46 kW

COP

5.20

3.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

Sound power level outdoor

49 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

161 %

Prated

7.63 kW

7.50 kW

SCOP

5.44

4.09

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.67 kW

6.90 kW

COP Tj = -7°C

3.50

2.60

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.06 kW

4.14 kW

COP Tj = +2°C

5.29

3.94

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.04 kW

2.88 kW

COP Tj = +7°C

6.95

5.23

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.59 kW

3.39 kW

COP Tj = 12°C

9.48

7.40

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

7.63 kW

7.50 kW

COP Tj = Tbiv

2.91

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.63 kW

7.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.91

2.29

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

14 W

14 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2896 kWh

3789 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

140 %

COP

3.49

Heating up time

1:40 h:min

Standby power input

29.0 W

Reference hot water temperature

45.7 °C

Mixed water at 40°C

190 l