Certificate holders

Subtype

Air to water heat pump 15K

Certificate Holder
HP+ BV
Nijverheidsstraat 7
3990 Peer
Belgium
Registration number
011-1W1332
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Air to water heat pump 15K
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,750 kg

Certification Date
06.08.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 2

Models

Indoor unit ZY-IU-SOL and outdoor unit HP-OU-15
Configure model
Model name
Indoor unit ZY-IU-SOL and outdoor unit HP-OU-15
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.28 kW

13.98 kW

El input

1.97 kW

4.67 kW

COP

5.22

2.99

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

34 dB(A)

Sound power level outdoor

54 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

158 %

Prated

13.14 kW

12.41 kW

SCOP

5.34

4.03

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

10.64 kW

COP Tj = -7°C

3.39

2.54

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.27 kW

6.78 kW

COP Tj = +2°C

5.16

3.87

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

5.38 kW

5.19 kW

COP Tj = +7°C

7.15

5.39

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

6.29 kW

6.10 kW

COP Tj = 12°C

9.52

7.34

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

13.14 kW

12.41 kW

COP Tj = Tbiv

2.59

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.14 kW

12.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

43 W

43 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5082 kWh

6360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

132 %

COP

3.31

Heating up time

1:5 h:min

Standby power input

30.0 W

Reference hot water temperature

45.3 °C

Mixed water at 40°C

185 l

Indoor unit CA-IU-AIO and outdoor unit HP-OU-15
Configure model
Model name
Indoor unit CA-IU-AIO and outdoor unit HP-OU-15
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.28 kW

13.98 kW

El input

1.97 kW

4.67 kW

COP

5.22

2.99

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

34 dB(A)

Sound power level outdoor

54 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

158 %

Prated

13.14 kW

12.41 kW

SCOP

5.34

4.03

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

10.64 kW

COP Tj = -7°C

3.39

2.54

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.27 kW

6.78 kW

COP Tj = +2°C

5.16

3.87

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

5.38 kW

5.19 kW

COP Tj = +7°C

7.15

5.39

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

6.29 kW

6.10 kW

COP Tj = 12°C

9.52

7.34

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

13.14 kW

12.41 kW

COP Tj = Tbiv

2.59

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.14 kW

12.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

43 W

43 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5082 kWh

6360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

132 %

COP

3.31

Heating up time

1:5 h:min

Standby power input

30.0 W

Reference hot water temperature

45.3 °C

Mixed water at 40°C

185 l