Certificate holders

Subtype

Xp Energy series and AquaSnap series 4 6 kW

Certificate Holder
Foshan Midea Carrier Air-conditioning Equipment Co., Ltd.
Foshan Midea Carrier Air-conditioning Equipment Co., Ltd. Lingang Road No.22
528311 Guangdong
China
Registration number
041-K124-01
Certification Body
BRE
Subtype title
Xp Energy series and AquaSnap series 4 6 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
15.06.2026
Testing basis
HP KEYMARK certification scheme rules rev. no.08
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 6

Models

30AWH004H----M
Configure model
Model name
30AWH004H----M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.2 kW

4.4 kW

El input

0.82 kW

1.49 kW

COP

5.1

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

162 %

Prated

5.54 kW

5.02 kW

SCOP

6.52

4.14

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.35 kW

4.84 kW

COP Tj = +2°C

3.94

2.51

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.56 kW

3.23 kW

COP Tj = +7°C

5.92

3.68

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.64 kW

1.47 kW

COP Tj = 12°C

7.91

5.15

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.56 kW

3.23 kW

COP Tj = Tbiv

5.92

3.68

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.35 kW

4.84 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.94

2.51

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.19 kW

0.18 kW

Annual energy consumption Qhe

1152 kWh

1621 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

102 %

Prated

4.57 kW

3.37 kW

SCOP

4.06

2.63

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.76 kW

2.14 kW

COP Tj = -7°C

3.49

2.32

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

1.77 kW

1.28 kW

COP Tj = +2°C

4.95

2.99

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.17 kW

1.01 kW

COP Tj = +7°C

5.53

3.86

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.43 kW

1.36 kW

COP Tj = 12°C

7.67

6.28

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.72 kW

2.75 kW

COP Tj = Tbiv

2.57

1.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.8 kW

1.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.97

1.02

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.76 kW

1.73 kW

Annual energy consumption Qhe

2770 kWh

3159 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.72

2.75

COP Tj = -15°C (if TOL<-20°C)

2.57

1.74

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

130 %

Prated

5.52 kW

4.4 kW

SCOP

4.85

3.31

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.88 kW

3.89 kW

COP Tj = -7°C

3.19

2.17

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.06 kW

2.38 kW

COP Tj = +2°C

4.78

3.3

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.93 kW

2.95 kW

COP Tj = +7°C

6.13

4.41

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.48 kW

1.32 kW

COP Tj = 12°C

8.05

5.66

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

4.88 kW

3.89 kW

COP Tj = Tbiv

3.19

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.42 kW

3.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.91

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.11 kW

0.98 kW

Annual energy consumption Qhe

2351 kWh

2744 kWh

30AWH004H----M3
Configure model
Model name
30AWH004H----M3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.2 kW

4.4 kW

El input

0.82 kW

1.49 kW

COP

5.1

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

162 %

Prated

5.54 kW

5.02 kW

SCOP

6.52

4.14

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.35 kW

4.84 kW

COP Tj = +2°C

3.94

2.51

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.56 kW

3.23 kW

COP Tj = +7°C

5.92

3.68

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.64 kW

1.47 kW

COP Tj = 12°C

7.91

5.15

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.56 kW

3.23 kW

COP Tj = Tbiv

5.92

3.68

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.35 kW

4.84 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.94

2.51

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.19 kW

0.18 kW

Annual energy consumption Qhe

1152 kWh

1621 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

102 %

Prated

4.57 kW

3.37 kW

SCOP

4.06

2.63

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.76 kW

2.14 kW

COP Tj = -7°C

3.49

2.32

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

1.77 kW

1.28 kW

COP Tj = +2°C

4.95

2.99

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.17 kW

1.01 kW

COP Tj = +7°C

5.53

3.86

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.43 kW

1.36 kW

COP Tj = 12°C

7.67

6.28

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.72 kW

2.75 kW

COP Tj = Tbiv

2.57

1.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.8 kW

1.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.97

1.02

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.76 kW

1.73 kW

Annual energy consumption Qhe

2770 kWh

3159 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.72

2.75

COP Tj = -15°C (if TOL<-20°C)

2.57

1.74

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

130 %

Prated

5.52 kW

4.4 kW

SCOP

4.85

3.31

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.88 kW

3.89 kW

COP Tj = -7°C

3.19

2.17

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.06 kW

2.38 kW

COP Tj = +2°C

4.78

3.3

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.93 kW

2.95 kW

COP Tj = +7°C

6.13

4.41

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.48 kW

1.32 kW

COP Tj = 12°C

8.05

5.66

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

4.88 kW

3.89 kW

COP Tj = Tbiv

3.19

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.42 kW

3.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.91

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.11 kW

0.98 kW

Annual energy consumption Qhe

2351 kWh

2744 kWh

30AWH006H----M
Configure model
Model name
30AWH006H----M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.35 kW

6 kW

El input

1.28 kW

2.03 kW

COP

4.95

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

258 %

165 %

Prated

6.12 kW

5.15 kW

SCOP

6.63

4.19

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.94 kW

5.03 kW

COP Tj = +2°C

3.91

2.48

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.93 kW

3.31 kW

COP Tj = +7°C

5.89

3.67

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.8 kW

1.6 kW

COP Tj = 12°C

8.2

5.29

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.93 kW

3.31 kW

COP Tj = Tbiv

5.89

3.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.94 kW

5.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.91

2.48

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.18 kW

0.12 kW

Annual energy consumption Qhe

1251 kWh

1640 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

111 %

Prated

5.63 kW

4.26 kW

SCOP

4.21

2.85

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.42 kW

2.7 kW

COP Tj = -7°C

3.59

2.46

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

2.06 kW

1.61 kW

COP Tj = +2°C

5.21

3.36

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.47 kW

1.02 kW

COP Tj = +7°C

6.24

3.94

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.44 kW

1.37 kW

COP Tj = 12°C

7.66

6.35

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

4.6 kW

3.48 kW

COP Tj = Tbiv

2.53

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.48 kW

2.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.13

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.15 kW

2.16 kW

Annual energy consumption Qhe

3301 kWh

3681 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.6

3.48

COP Tj = -15°C (if TOL<-20°C)

2.53

1.86

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

138 %

Prated

6.82 kW

5.7 kW

SCOP

4.95

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.03 kW

5.05 kW

COP Tj = -7°C

3.09

2.17

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.88 kW

3.12 kW

COP Tj = +2°C

4.85

3.51

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

2.4 kW

2.09 kW

COP Tj = +7°C

6.63

4.54

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.39 kW

1.28 kW

COP Tj = 12°C

7.83

5.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

6.03 kW

5.05 kW

COP Tj = Tbiv

3.09

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.36 kW

4.52 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.91

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.45 kW

1.18 kW

Annual energy consumption Qhe

2846 kWh

3345 kWh

30AWH006H----M3
Configure model
Model name
30AWH006H----M3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.35 kW

6 kW

El input

1.28 kW

2.03 kW

COP

4.95

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

258 %

165 %

Prated

6.12 kW

5.15 kW

SCOP

6.63

4.19

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.94 kW

5.03 kW

COP Tj = +2°C

3.91

2.48

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.93 kW

3.31 kW

COP Tj = +7°C

5.89

3.67

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.8 kW

1.6 kW

COP Tj = 12°C

8.2

5.29

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.93 kW

3.31 kW

COP Tj = Tbiv

5.89

3.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.94 kW

5.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.91

2.48

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.18 kW

0.12 kW

Annual energy consumption Qhe

1251 kWh

1640 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

111 %

Prated

5.63 kW

4.26 kW

SCOP

4.21

2.85

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.42 kW

2.7 kW

COP Tj = -7°C

3.59

2.46

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

2.06 kW

1.61 kW

COP Tj = +2°C

5.21

3.36

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.47 kW

1.02 kW

COP Tj = +7°C

6.24

3.94

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.44 kW

1.37 kW

COP Tj = 12°C

7.66

6.35

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

4.6 kW

3.48 kW

COP Tj = Tbiv

2.53

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.48 kW

2.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.13

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.15 kW

2.16 kW

Annual energy consumption Qhe

3301 kWh

3681 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.6

3.48

COP Tj = -15°C (if TOL<-20°C)

2.53

1.86

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

138 %

Prated

6.82 kW

5.7 kW

SCOP

4.95

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.03 kW

5.05 kW

COP Tj = -7°C

3.09

2.17

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.88 kW

3.12 kW

COP Tj = +2°C

4.85

3.51

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

2.4 kW

2.09 kW

COP Tj = +7°C

6.63

4.54

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.39 kW

1.28 kW

COP Tj = 12°C

7.83

5.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

6.03 kW

5.05 kW

COP Tj = Tbiv

3.09

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.36 kW

4.52 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.91

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.45 kW

1.18 kW

Annual energy consumption Qhe

2846 kWh

3345 kWh

38AW040H7R / 80AWX060M*BR
Configure model
Model name
38AW040H7R / 80AWX060M*BR
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.25 kW

4.4 kW

El input

0.82 kW

1.49 kW

COP

5.2

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

162 %

Prated

5.54 kW

5.02 kW

SCOP

6.52

4.14

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.35 kW

4.84 kW

COP Tj = +2°C

3.94

2.51

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.56 kW

3.23 kW

COP Tj = +7°C

5.92

3.68

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.64 kW

1.47 kW

COP Tj = 12°C

7.91

5.15

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.56 kW

3.23 kW

COP Tj = Tbiv

5.92

3.68

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.35 kW

4.84 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.94

2.51

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.19 kW

0.18 kW

Annual energy consumption Qhe

1152 kWh

1621 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

102 %

Prated

4.57 kW

3.37 kW

SCOP

4.06

2.63

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.76 kW

2.14 kW

COP Tj = -7°C

3.49

2.32

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

1.77 kW

1.28 kW

COP Tj = +2°C

4.95

2.99

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.17 kW

1.01 kW

COP Tj = +7°C

5.53

3.86

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.43 kW

1.36 kW

COP Tj = 12°C

7.67

6.28

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.72 kW

2.75 kW

COP Tj = Tbiv

2.57

1.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.8 kW

1.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.97

1.02

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.76 kW

1.73 kW

Annual energy consumption Qhe

2770 kWh

3159 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.72

2.75

COP Tj = -15°C (if TOL<-20°C)

2.57

1.74

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

130 %

Prated

5.52 kW

4.4 kW

SCOP

4.85

3.31

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.88 kW

3.89 kW

COP Tj = -7°C

3.19

2.17

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.06 kW

2.38 kW

COP Tj = +2°C

4.78

3.3

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.93 kW

2.95 kW

COP Tj = +7°C

6.13

4.41

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.48 kW

1.32 kW

COP Tj = 12°C

8.05

5.66

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

4.88 kW

3.89 kW

COP Tj = Tbiv

3.19

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.42 kW

3.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.91

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.11 kW

0.98 kW

Annual energy consumption Qhe

2351 kWh

2744 kWh

38AW060H7R / 80AWX060M*BR
Configure model
Model name
38AW060H7R / 80AWX060M*BR
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.2 kW

6 kW

El input

1.24 kW

2 kW

COP

5

3

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

258 %

165 %

Prated

6.12 kW

5.15 kW

SCOP

6.63

4.19

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.94 kW

5.03 kW

COP Tj = +2°C

3.91

2.48

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.93 kW

3.31 kW

COP Tj = +7°C

5.89

3.67

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.8 kW

1.6 kW

COP Tj = 12°C

8.2

5.29

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.93 kW

3.31 kW

COP Tj = Tbiv

5.89

3.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.94 kW

5.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.91

2.48

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.18 kW

0.12 kW

Annual energy consumption Qhe

1251 kWh

1640 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

111 %

Prated

5.63 kW

4.26 kW

SCOP

4.21

2.85

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.42 kW

2.7 kW

COP Tj = -7°C

3.59

2.46

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

2.06 kW

1.61 kW

COP Tj = +2°C

5.21

3.36

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.47 kW

1.02 kW

COP Tj = +7°C

6.24

3.94

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.44 kW

1.37 kW

COP Tj = 12°C

7.66

6.35

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

4.6 kW

3.48 kW

COP Tj = Tbiv

2.53

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.48 kW

2.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.13

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.15 kW

2.16 kW

Annual energy consumption Qhe

3301 kWh

3681 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.6

3.48

COP Tj = -15°C (if TOL<-20°C)

2.53

1.86

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

138 %

Prated

6.82 kW

5.7 kW

SCOP

4.95

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.03 kW

5.05 kW

COP Tj = -7°C

3.09

2.17

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.88 kW

3.12 kW

COP Tj = +2°C

4.85

3.51

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

2.4 kW

2.09 kW

COP Tj = +7°C

6.63

4.54

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.39 kW

1.28 kW

COP Tj = 12°C

7.83

5.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

6.03 kW

5.05 kW

COP Tj = Tbiv

3.09

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.36 kW

4.52 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.91

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.45 kW

1.18 kW

Annual energy consumption Qhe

2846 kWh

3345 kWh