1,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.64 kW
4.67 kW
El input
0.87 kW
1.59 kW
COP
5.35
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
186 %
Prated
10.2 kW
10.5 kW
SCOP
6.34
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.22 kW
10.5 kW
COP Tj = +2°C
3.18
2.48
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.5 kW
7.12 kW
COP Tj = +7°C
5.95
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.29 kW
COP Tj = 12°C
7.49
5.82
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.22 kW
10.5 kW
COP Tj = Tbiv
3.18
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.22 kW
10.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2151 kWh
2970 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
143 %
Prated
11 kW
11 kW
SCOP
4.6
3.65
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.78 kW
6.58 kW
COP Tj = -7°C
3.87
3.08
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.18 kW
4.01 kW
COP Tj = +2°C
5.72
4.43
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.81 kW
4.67 kW
COP Tj = +7°C
6.66
5.37
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.51 kW
5.4 kW
COP Tj = 12°C
7.58
6.45
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.11 kW
8.9 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.47 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.53 kW
3.8 kW
Annual energy consumption Qhe
5891 kWh
7436 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.11
8.9
COP Tj = -15°C (if TOL<-20°C)
2.73
2.18
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
213 %
162 %
Prated
11 kW
11 kW
SCOP
5.4
4.12
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.83 kW
9.38 kW
COP Tj = -7°C
3.32
2.57
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.67 kW
5.84 kW
COP Tj = +2°C
5.41
4.09
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.93 kW
4.73 kW
COP Tj = +7°C
6.82
5.19
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.65 kW
5.54 kW
COP Tj = 12°C
8.29
6.62
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.83 kW
9.38 kW
COP Tj = Tbiv
3.32
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.25 kW
10.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.88 kW
Annual energy consumption Qhe
4209 kWh
5513 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.64 kW
4.67 kW
El input
0.87 kW
1.59 kW
COP
5.35
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
186 %
Prated
10.2 kW
10.5 kW
SCOP
6.34
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.22 kW
10.5 kW
COP Tj = +2°C
3.18
2.48
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.5 kW
7.12 kW
COP Tj = +7°C
5.95
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.29 kW
COP Tj = 12°C
7.49
5.82
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.22 kW
10.5 kW
COP Tj = Tbiv
3.18
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.22 kW
10.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2151 kWh
2970 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
143 %
Prated
11 kW
11 kW
SCOP
4.6
3.65
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.78 kW
6.58 kW
COP Tj = -7°C
3.87
3.08
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.18 kW
4.01 kW
COP Tj = +2°C
5.72
4.43
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.81 kW
4.67 kW
COP Tj = +7°C
6.66
5.37
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.51 kW
5.4 kW
COP Tj = 12°C
7.58
6.45
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.11 kW
8.9 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.47 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.53 kW
3.8 kW
Annual energy consumption Qhe
5891 kWh
7436 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.11
8.9
COP Tj = -15°C (if TOL<-20°C)
2.73
2.18
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
213 %
162 %
Prated
11 kW
11 kW
SCOP
5.4
4.12
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.83 kW
9.38 kW
COP Tj = -7°C
3.32
2.57
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.67 kW
5.84 kW
COP Tj = +2°C
5.41
4.09
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.93 kW
4.73 kW
COP Tj = +7°C
6.82
5.19
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.65 kW
5.54 kW
COP Tj = 12°C
8.29
6.62
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.83 kW
9.38 kW
COP Tj = Tbiv
3.32
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.25 kW
10.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.88 kW
Annual energy consumption Qhe
4209 kWh
5513 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.64 kW
4.67 kW
El input
0.87 kW
1.59 kW
COP
5.35
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
186 %
Prated
10.2 kW
10.5 kW
SCOP
6.34
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.22 kW
10.5 kW
COP Tj = +2°C
3.18
2.48
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.5 kW
7.12 kW
COP Tj = +7°C
5.95
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.29 kW
COP Tj = 12°C
7.49
5.82
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.22 kW
10.5 kW
COP Tj = Tbiv
3.18
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.22 kW
10.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2151 kWh
2970 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
143 %
Prated
11 kW
11 kW
SCOP
4.6
3.65
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.78 kW
6.58 kW
COP Tj = -7°C
3.87
3.08
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.18 kW
4.01 kW
COP Tj = +2°C
5.72
4.43
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.81 kW
4.67 kW
COP Tj = +7°C
6.66
5.37
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.51 kW
5.4 kW
COP Tj = 12°C
7.58
6.45
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.11 kW
8.9 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.47 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.53 kW
3.8 kW
Annual energy consumption Qhe
5891 kWh
7436 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.11
8.9
COP Tj = -15°C (if TOL<-20°C)
2.73
2.18
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
213 %
162 %
Prated
11 kW
11 kW
SCOP
5.4
4.12
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.83 kW
9.38 kW
COP Tj = -7°C
3.32
2.57
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.67 kW
5.84 kW
COP Tj = +2°C
5.41
4.09
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.93 kW
4.73 kW
COP Tj = +7°C
6.82
5.19
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.65 kW
5.54 kW
COP Tj = 12°C
8.29
6.62
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.83 kW
9.38 kW
COP Tj = Tbiv
3.32
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.25 kW
10.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.88 kW
Annual energy consumption Qhe
4209 kWh
5513 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.64 kW
4.67 kW
El input
0.87 kW
1.59 kW
COP
5.35
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
186 %
Prated
10.2 kW
10.5 kW
SCOP
6.34
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.22 kW
10.5 kW
COP Tj = +2°C
3.18
2.48
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.5 kW
7.12 kW
COP Tj = +7°C
5.95
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.29 kW
COP Tj = 12°C
7.49
5.82
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.22 kW
10.5 kW
COP Tj = Tbiv
3.18
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.22 kW
10.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2151 kWh
2970 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
143 %
Prated
11 kW
11 kW
SCOP
4.6
3.65
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.78 kW
6.58 kW
COP Tj = -7°C
3.87
3.08
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.18 kW
4.01 kW
COP Tj = +2°C
5.72
4.43
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.81 kW
4.67 kW
COP Tj = +7°C
6.66
5.37
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.51 kW
5.4 kW
COP Tj = 12°C
7.58
6.45
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.11 kW
8.9 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.47 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.53 kW
3.8 kW
Annual energy consumption Qhe
5891 kWh
7436 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.11
8.9
COP Tj = -15°C (if TOL<-20°C)
2.73
2.18
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
213 %
162 %
Prated
11 kW
11 kW
SCOP
5.4
4.12
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.83 kW
9.38 kW
COP Tj = -7°C
3.32
2.57
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.67 kW
5.84 kW
COP Tj = +2°C
5.41
4.09
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.93 kW
4.73 kW
COP Tj = +7°C
6.82
5.19
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.65 kW
5.54 kW
COP Tj = 12°C
8.29
6.62
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.83 kW
9.38 kW
COP Tj = Tbiv
3.32
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.25 kW
10.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.88 kW
Annual energy consumption Qhe
4209 kWh
5513 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.4 kW
4.67 kW
El input
1 kW
1.59 kW
COP
5.4
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
187 %
Prated
11 kW
12 kW
SCOP
6.32
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.12 kW
11.68 kW
COP Tj = +2°C
2.99
2.37
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.01 kW
7.58 kW
COP Tj = +7°C
5.9
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.32 kW
COP Tj = 12°C
7.56
5.95
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.12 kW
11.68 kW
COP Tj = Tbiv
2.99
2.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.12 kW
11.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2327 kWh
3370 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
142 %
Prated
13 kW
13 kW
SCOP
4.5
3.61
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.7 kW
8.1 kW
COP Tj = -7°C
3.75
2.99
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.86 kW
4.67 kW
COP Tj = +2°C
5.68
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.83 kW
4.69 kW
COP Tj = +7°C
6.75
5.48
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.52 kW
5.41 kW
COP Tj = 12°C
7.63
6.5
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.86 kW
10.69 kW
COP Tj = Tbiv
2.51
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.06 kW
8.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.94 kW
4.19 kW
Annual energy consumption Qhe
7116 kWh
8869 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.86
10.69
COP Tj = -15°C (if TOL<-20°C)
2.51
2.04
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
212 %
162 %
Prated
13 kW
13 kW
SCOP
5.37
4.13
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.81 kW
11.47 kW
COP Tj = -7°C
3.09
2.45
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.70 kW
6.79 kW
COP Tj = +2°C
5.39
4.11
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.04 kW
4.85 kW
COP Tj = +7°C
7.03
5.35
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.82 kW
5.67 kW
COP Tj = 12°C
8.38
6.70
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.81 kW
11.47 kW
COP Tj = Tbiv
3.09
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.40 kW
12.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
0.94 kW
Annual energy consumption Qhe
5005 kWh
6502 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.4 kW
4.67 kW
El input
1 kW
1.59 kW
COP
5.4
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
187 %
Prated
11 kW
12 kW
SCOP
6.32
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.12 kW
11.68 kW
COP Tj = +2°C
2.99
2.37
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.01 kW
7.58 kW
COP Tj = +7°C
5.9
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.32 kW
COP Tj = 12°C
7.56
5.95
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.12 kW
11.68 kW
COP Tj = Tbiv
2.99
2.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.12 kW
11.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2327 kWh
3370 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
142 %
Prated
13 kW
13 kW
SCOP
4.5
3.61
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.7 kW
8.1 kW
COP Tj = -7°C
3.75
2.99
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.86 kW
4.67 kW
COP Tj = +2°C
5.68
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.83 kW
4.69 kW
COP Tj = +7°C
6.75
5.48
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.52 kW
5.41 kW
COP Tj = 12°C
7.63
6.5
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.86 kW
10.69 kW
COP Tj = Tbiv
2.51
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.06 kW
8.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.94 kW
4.19 kW
Annual energy consumption Qhe
7116 kWh
8869 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.86
10.69
COP Tj = -15°C (if TOL<-20°C)
2.51
2.04
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
212 %
162 %
Prated
13 kW
13 kW
SCOP
5.37
4.13
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.81 kW
11.47 kW
COP Tj = -7°C
3.09
2.45
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.70 kW
6.79 kW
COP Tj = +2°C
5.39
4.11
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.04 kW
4.85 kW
COP Tj = +7°C
7.03
5.35
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.82 kW
5.67 kW
COP Tj = 12°C
8.38
6.70
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.81 kW
11.47 kW
COP Tj = Tbiv
3.09
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.40 kW
12.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
0.94 kW
Annual energy consumption Qhe
5005 kWh
6502 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.4 kW
4.67 kW
El input
1 kW
1.59 kW
COP
5.4
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
187 %
Prated
11 kW
12 kW
SCOP
6.32
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.12 kW
11.68 kW
COP Tj = +2°C
2.99
2.37
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.01 kW
7.58 kW
COP Tj = +7°C
5.9
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.32 kW
COP Tj = 12°C
7.56
5.95
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.12 kW
11.68 kW
COP Tj = Tbiv
2.99
2.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.12 kW
11.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2327 kWh
3370 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
142 %
Prated
13 kW
13 kW
SCOP
4.5
3.61
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.7 kW
8.1 kW
COP Tj = -7°C
3.75
2.99
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.86 kW
4.67 kW
COP Tj = +2°C
5.68
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.83 kW
4.69 kW
COP Tj = +7°C
6.75
5.48
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.52 kW
5.41 kW
COP Tj = 12°C
7.63
6.5
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.86 kW
10.69 kW
COP Tj = Tbiv
2.51
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.06 kW
8.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.94 kW
4.19 kW
Annual energy consumption Qhe
7116 kWh
8869 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.86
10.69
COP Tj = -15°C (if TOL<-20°C)
2.51
2.04
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
212 %
162 %
Prated
13 kW
13 kW
SCOP
5.37
4.13
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.81 kW
11.47 kW
COP Tj = -7°C
3.09
2.45
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.70 kW
6.79 kW
COP Tj = +2°C
5.39
4.11
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.04 kW
4.85 kW
COP Tj = +7°C
7.03
5.35
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.82 kW
5.67 kW
COP Tj = 12°C
8.38
6.70
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.81 kW
11.47 kW
COP Tj = Tbiv
3.09
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.40 kW
12.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
0.94 kW
Annual energy consumption Qhe
5005 kWh
6502 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.4 kW
4.67 kW
El input
1 kW
1.59 kW
COP
5.4
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
187 %
Prated
11 kW
12 kW
SCOP
6.32
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.12 kW
11.68 kW
COP Tj = +2°C
2.99
2.37
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.01 kW
7.58 kW
COP Tj = +7°C
5.9
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.32 kW
COP Tj = 12°C
7.56
5.95
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.12 kW
11.68 kW
COP Tj = Tbiv
2.99
2.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.12 kW
11.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2327 kWh
3370 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
142 %
Prated
13 kW
13 kW
SCOP
4.5
3.61
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.7 kW
8.1 kW
COP Tj = -7°C
3.75
2.99
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.86 kW
4.67 kW
COP Tj = +2°C
5.68
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.83 kW
4.69 kW
COP Tj = +7°C
6.75
5.48
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.52 kW
5.41 kW
COP Tj = 12°C
7.63
6.5
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.86 kW
10.69 kW
COP Tj = Tbiv
2.51
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.06 kW
8.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.94 kW
4.19 kW
Annual energy consumption Qhe
7116 kWh
8869 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.86
10.69
COP Tj = -15°C (if TOL<-20°C)
2.51
2.04
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
212 %
162 %
Prated
13 kW
13 kW
SCOP
5.37
4.13
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.81 kW
11.47 kW
COP Tj = -7°C
3.09
2.45
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.70 kW
6.79 kW
COP Tj = +2°C
5.39
4.11
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.04 kW
4.85 kW
COP Tj = +7°C
7.03
5.35
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.82 kW
5.67 kW
COP Tj = 12°C
8.38
6.70
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.81 kW
11.47 kW
COP Tj = Tbiv
3.09
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.40 kW
12.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
0.94 kW
Annual energy consumption Qhe
5005 kWh
6502 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.39 kW
5.15 kW
El input
1.19 kW
1.72 kW
COP
5.38
2.99
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
188 %
Prated
12.5 kW
13 kW
SCOP
6.25
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.48 kW
13.21 kW
COP Tj = +2°C
2.88
2.29
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.98 kW
8.29 kW
COP Tj = +7°C
5.78
4.18
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.33 kW
COP Tj = 12°C
7.58
6.03
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.48 kW
13.21 kW
COP Tj = Tbiv
2.88
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.48 kW
13.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.88
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2671 kWh
3645 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
138 %
Prated
15 kW
15 kW
SCOP
4.33
3.54
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.93 kW
9.23 kW
COP Tj = -7°C
3.56
2.87
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.76 kW
5.57 kW
COP Tj = +2°C
5.53
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.85 kW
4.71 kW
COP Tj = +7°C
6.85
5.59
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.53 kW
5.42 kW
COP Tj = 12°C
7.67
6.56
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.21 kW
12.08 kW
COP Tj = Tbiv
2.38
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.25 kW
9.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.75 kW
5.6 kW
Annual energy consumption Qhe
8532 kWh
10455 kWh
Pdh Tj = -15°C (if TOL<-20°C)
12.21
12.08
COP Tj = -15°C (if TOL<-20°C)
2.38
1.93
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
157 %
Prated
15 kW
15 kW
SCOP
5.02
3.99
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.98 kW
12.81 kW
COP Tj = -7°C
2.93
2.34
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.99 kW
7.73 kW
COP Tj = +2°C
4.90
3.93
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.15 kW
5.03 kW
COP Tj = +7°C
6.92
5.34
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.64 kW
5.52 kW
COP Tj = 12°C
8.32
6.54
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.98 kW
12.81 kW
COP Tj = Tbiv
2.93
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.83 kW
13.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.17 kW
1.42 kW
Annual energy consumption Qhe
6168 kWh
7769 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.39 kW
5.15 kW
El input
1.19 kW
1.72 kW
COP
5.38
2.99
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
188 %
Prated
12.5 kW
13 kW
SCOP
6.25
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.48 kW
13.21 kW
COP Tj = +2°C
2.88
2.29
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.98 kW
8.29 kW
COP Tj = +7°C
5.78
4.18
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.33 kW
COP Tj = 12°C
7.58
6.03
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.48 kW
13.21 kW
COP Tj = Tbiv
2.88
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.48 kW
13.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.88
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2671 kWh
3645 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
138 %
Prated
15 kW
15 kW
SCOP
4.33
3.54
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.93 kW
9.23 kW
COP Tj = -7°C
3.56
2.87
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.76 kW
5.57 kW
COP Tj = +2°C
5.53
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.85 kW
4.71 kW
COP Tj = +7°C
6.85
5.59
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.53 kW
5.42 kW
COP Tj = 12°C
7.67
6.56
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.21 kW
12.08 kW
COP Tj = Tbiv
2.38
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.25 kW
9.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.75 kW
5.6 kW
Annual energy consumption Qhe
8532 kWh
10455 kWh
Pdh Tj = -15°C (if TOL<-20°C)
12.21
12.08
COP Tj = -15°C (if TOL<-20°C)
2.38
1.93
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
157 %
Prated
15 kW
15 kW
SCOP
5.02
3.99
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.98 kW
12.81 kW
COP Tj = -7°C
2.93
2.34
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.99 kW
7.73 kW
COP Tj = +2°C
4.90
3.93
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.15 kW
5.03 kW
COP Tj = +7°C
6.92
5.34
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.64 kW
5.52 kW
COP Tj = 12°C
8.32
6.54
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.98 kW
12.81 kW
COP Tj = Tbiv
2.93
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.83 kW
13.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.17 kW
1.42 kW
Annual energy consumption Qhe
6168 kWh
7769 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.39 kW
5.15 kW
El input
1.19 kW
1.72 kW
COP
5.38
2.99
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
188 %
Prated
12.5 kW
13 kW
SCOP
6.25
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.48 kW
13.21 kW
COP Tj = +2°C
2.88
2.29
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.98 kW
8.29 kW
COP Tj = +7°C
5.78
4.18
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.33 kW
COP Tj = 12°C
7.58
6.03
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.48 kW
13.21 kW
COP Tj = Tbiv
2.88
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.48 kW
13.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.88
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2671 kWh
3645 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
138 %
Prated
15 kW
15 kW
SCOP
4.33
3.54
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.93 kW
9.23 kW
COP Tj = -7°C
3.56
2.87
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.76 kW
5.57 kW
COP Tj = +2°C
5.53
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.85 kW
4.71 kW
COP Tj = +7°C
6.85
5.59
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.53 kW
5.42 kW
COP Tj = 12°C
7.67
6.56
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.21 kW
12.08 kW
COP Tj = Tbiv
2.38
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.25 kW
9.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.75 kW
5.6 kW
Annual energy consumption Qhe
8532 kWh
10455 kWh
Pdh Tj = -15°C (if TOL<-20°C)
12.21
12.08
COP Tj = -15°C (if TOL<-20°C)
2.38
1.93
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
157 %
Prated
15 kW
15 kW
SCOP
5.02
3.99
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.98 kW
12.81 kW
COP Tj = -7°C
2.93
2.34
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.99 kW
7.73 kW
COP Tj = +2°C
4.90
3.93
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.15 kW
5.03 kW
COP Tj = +7°C
6.92
5.34
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.64 kW
5.52 kW
COP Tj = 12°C
8.32
6.54
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.98 kW
12.81 kW
COP Tj = Tbiv
2.93
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.83 kW
13.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.17 kW
1.42 kW
Annual energy consumption Qhe
6168 kWh
7769 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.39 kW
5.15 kW
El input
1.19 kW
1.72 kW
COP
5.38
2.99
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
188 %
Prated
12.5 kW
13 kW
SCOP
6.25
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.48 kW
13.21 kW
COP Tj = +2°C
2.88
2.29
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.98 kW
8.29 kW
COP Tj = +7°C
5.78
4.18
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.33 kW
COP Tj = 12°C
7.58
6.03
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.48 kW
13.21 kW
COP Tj = Tbiv
2.88
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.48 kW
13.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.88
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2671 kWh
3645 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
138 %
Prated
15 kW
15 kW
SCOP
4.33
3.54
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.93 kW
9.23 kW
COP Tj = -7°C
3.56
2.87
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.76 kW
5.57 kW
COP Tj = +2°C
5.53
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.85 kW
4.71 kW
COP Tj = +7°C
6.85
5.59
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.53 kW
5.42 kW
COP Tj = 12°C
7.67
6.56
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.21 kW
12.08 kW
COP Tj = Tbiv
2.38
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.25 kW
9.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.75 kW
5.6 kW
Annual energy consumption Qhe
8532 kWh
10455 kWh
Pdh Tj = -15°C (if TOL<-20°C)
12.21
12.08
COP Tj = -15°C (if TOL<-20°C)
2.38
1.93
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
157 %
Prated
15 kW
15 kW
SCOP
5.02
3.99
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.98 kW
12.81 kW
COP Tj = -7°C
2.93
2.34
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.99 kW
7.73 kW
COP Tj = +2°C
4.90
3.93
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.15 kW
5.03 kW
COP Tj = +7°C
6.92
5.34
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.64 kW
5.52 kW
COP Tj = 12°C
8.32
6.54
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.98 kW
12.81 kW
COP Tj = Tbiv
2.93
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.83 kW
13.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.17 kW
1.42 kW
Annual energy consumption Qhe
6168 kWh
7769 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.64 kW
4.67 kW
El input
0.87 kW
1.59 kW
COP
5.35
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
186 %
Prated
10.2 kW
10.5 kW
SCOP
6.34
4.72
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.22 kW
10.5 kW
COP Tj = +2°C
3.18
2.48
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
6.5 kW
7.12 kW
COP Tj = +7°C
5.95
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.29 kW
COP Tj = 12°C
7.49
5.82
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.22 kW
10.5 kW
COP Tj = Tbiv
3.18
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.22 kW
10.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2151 kWh
2970 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
143 %
Prated
11 kW
11 kW
SCOP
4.6
3.65
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.78 kW
6.58 kW
COP Tj = -7°C
3.87
3.08
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.18 kW
4.01 kW
COP Tj = +2°C
5.72
4.43
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.81 kW
4.67 kW
COP Tj = +7°C
6.66
5.37
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.51 kW
5.4 kW
COP Tj = 12°C
7.58
6.45
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.11 kW
8.9 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.47 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.53 kW
3.8 kW
Annual energy consumption Qhe
5891 kWh
7436 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.11
8.9
COP Tj = -15°C (if TOL<-20°C)
2.73
2.18
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
213 %
162 %
Prated
11 kW
11 kW
SCOP
5.4
4.12
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.83 kW
9.38 kW
COP Tj = -7°C
3.32
2.57
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.67 kW
5.84 kW
COP Tj = +2°C
5.41
4.09
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
4.93 kW
4.73 kW
COP Tj = +7°C
6.82
5.19
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.65 kW
5.54 kW
COP Tj = 12°C
8.29
6.62
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
9.83 kW
9.38 kW
COP Tj = Tbiv
3.32
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.25 kW
10.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.88 kW
Annual energy consumption Qhe
4209 kWh
5513 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.4 kW
4.67 kW
El input
1 kW
1.59 kW
COP
5.4
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
250 %
187 %
Prated
11 kW
12 kW
SCOP
6.32
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.12 kW
11.68 kW
COP Tj = +2°C
2.99
2.37
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.01 kW
7.58 kW
COP Tj = +7°C
5.9
4.2
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.32 kW
COP Tj = 12°C
7.56
5.95
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.12 kW
11.68 kW
COP Tj = Tbiv
2.99
2.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.12 kW
11.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2327 kWh
3370 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
142 %
Prated
13 kW
13 kW
SCOP
4.5
3.61
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.7 kW
8.1 kW
COP Tj = -7°C
3.75
2.99
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.86 kW
4.67 kW
COP Tj = +2°C
5.68
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.83 kW
4.69 kW
COP Tj = +7°C
6.75
5.48
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.52 kW
5.41 kW
COP Tj = 12°C
7.63
6.5
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
10.86 kW
10.69 kW
COP Tj = Tbiv
2.51
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.06 kW
8.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.94 kW
4.19 kW
Annual energy consumption Qhe
7116 kWh
8869 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.86
10.69
COP Tj = -15°C (if TOL<-20°C)
2.51
2.04
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
212 %
162 %
Prated
13 kW
13 kW
SCOP
5.37
4.13
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.81 kW
11.47 kW
COP Tj = -7°C
3.09
2.45
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.70 kW
6.79 kW
COP Tj = +2°C
5.39
4.11
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.04 kW
4.85 kW
COP Tj = +7°C
7.03
5.35
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.82 kW
5.67 kW
COP Tj = 12°C
8.38
6.70
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
11.81 kW
11.47 kW
COP Tj = Tbiv
3.09
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.40 kW
12.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
0.94 kW
Annual energy consumption Qhe
5005 kWh
6502 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.39 kW
5.15 kW
El input
1.19 kW
1.72 kW
COP
5.38
2.99
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
247 %
188 %
Prated
12.5 kW
13 kW
SCOP
6.25
4.76
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.48 kW
13.21 kW
COP Tj = +2°C
2.88
2.29
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
7.98 kW
8.29 kW
COP Tj = +7°C
5.78
4.18
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.51 kW
5.33 kW
COP Tj = 12°C
7.58
6.03
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.48 kW
13.21 kW
COP Tj = Tbiv
2.88
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.48 kW
13.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.88
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2671 kWh
3645 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
138 %
Prated
15 kW
15 kW
SCOP
4.33
3.54
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.93 kW
9.23 kW
COP Tj = -7°C
3.56
2.87
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.76 kW
5.57 kW
COP Tj = +2°C
5.53
4.5
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.85 kW
4.71 kW
COP Tj = +7°C
6.85
5.59
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.53 kW
5.42 kW
COP Tj = 12°C
7.67
6.56
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.21 kW
12.08 kW
COP Tj = Tbiv
2.38
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.25 kW
9.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.75 kW
5.6 kW
Annual energy consumption Qhe
8532 kWh
10455 kWh
Pdh Tj = -15°C (if TOL<-20°C)
12.21
12.08
COP Tj = -15°C (if TOL<-20°C)
2.38
1.93
Cdh Tj = -15 °C
1
1
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
157 %
Prated
15 kW
15 kW
SCOP
5.02
3.99
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.98 kW
12.81 kW
COP Tj = -7°C
2.93
2.34
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.99 kW
7.73 kW
COP Tj = +2°C
4.90
3.93
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.15 kW
5.03 kW
COP Tj = +7°C
6.92
5.34
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.64 kW
5.52 kW
COP Tj = 12°C
8.32
6.54
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.98 kW
12.81 kW
COP Tj = Tbiv
2.93
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.83 kW
13.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
75 °C
75 °C
Poff
17 W
17 W
PTO
6 W
6 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.17 kW
1.42 kW
Annual energy consumption Qhe
6168 kWh
7769 kWh