Certificate holders

Subtype

ATW HP 6K49-P

Certificate Holder
CHOFU SEISAKUSHO Co. Ltd.
2-1 Chofu Ohgimachi,
752-0927 Yamaguchi prefecture
Japan
Registration number
041-K128-02
Certification Body
BRE
Subtype title
ATW HP 6K49-P
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,850 kg

Certification Date
26.07.2026
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
SGS-CSTC Standards Technical Services Co., Ltd. Shunde Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AEYC-0649ZU-CH1
Configure model
Model name
AEYC-0649ZU-CH1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

4.20 kW

El input

1.23 kW

1.45 kW

COP

4.88

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

134 %

Prated

6.81 kW

6.69 kW

SCOP

4.46

3.43

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.92 kW

COP Tj = -7°C

2.68

2.05

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.65 kW

3.51 kW

COP Tj = +2°C

4.33

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.40 kW

2.22 kW

COP Tj = +7°C

6.03

4.59

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.34 kW

2.23 kW

COP Tj = 12°C

8.39

6.95

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.02 kW

5.92 kW

COP Tj = Tbiv

2.68

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.75 kW

5.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

11 W

PTO

12 W

12 W

PSB

10 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.10 kW

1.00 kW

Annual energy consumption Qhe

3153 kWh

4034 kWh