0,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
2.80 kW
El input
0.87 kW
1.08 kW
COP
4.60
2.59
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
129 %
Prated
5.21 kW
4.81 kW
SCOP
4.48
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.60 kW
4.26 kW
COP Tj = -7°C
2.66
1.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.86 kW
2.62 kW
COP Tj = +2°C
4.33
3.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.78 kW
1.57 kW
COP Tj = +7°C
6.38
4.29
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.61 kW
1.47 kW
COP Tj = 12°C
7.76
6.46
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.60 kW
4.26 kW
COP Tj = Tbiv
2.66
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.13 kW
3.83 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.42
1.77
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
5 W
5 W
PTO
21 W
25 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
1.00 kW
Annual energy consumption Qhe
2400 kWh
3003 kWh