Certificate holders

Subtype

ATW HP 4K49-P

Certificate Holder
CHOFU SEISAKUSHO Co. Ltd.
2-1 Chofu Ohgimachi,
752-0927 Yamaguchi prefecture
Japan
Registration number
041-K128-01
Certification Body
BRE
Subtype title
ATW HP 4K49-P
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,500 kg

Certification Date
26.07.2026
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
SGS-CSTC Standards Technical Services Co., Ltd. Shunde Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AEYC-0449ZU-CH1
Configure model
Model name
AEYC-0449ZU-CH1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

2.80 kW

El input

0.87 kW

1.08 kW

COP

4.60

2.59

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

5.21 kW

4.81 kW

SCOP

4.48

3.31

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.60 kW

4.26 kW

COP Tj = -7°C

2.66

1.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.86 kW

2.62 kW

COP Tj = +2°C

4.33

3.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.78 kW

1.57 kW

COP Tj = +7°C

6.38

4.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.61 kW

1.47 kW

COP Tj = 12°C

7.76

6.46

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.60 kW

4.26 kW

COP Tj = Tbiv

2.66

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.13 kW

3.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.42

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

5 W

5 W

PTO

21 W

25 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.10 kW

1.00 kW

Annual energy consumption Qhe

2400 kWh

3003 kWh