0,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
3.32 kW
El input
0.93 kW
1.11 kW
COP
4.32
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
127 %
Prated
2.36 kW
2.52 kW
SCOP
3.99
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
2.09 kW
2.23 kW
COP Tj = -7°C
2.49
2.12
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
1.24 kW
1.35 kW
COP Tj = +2°C
3.77
3.08
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
0.85 kW
0.86 kW
COP Tj = +7°C
5.49
4.18
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.90 kW
0.93 kW
COP Tj = 12°C
8.16
6.14
Cdh Tj = +12 °C
0.927
0.947
Pdh Tj = Tbiv
2.09 kW
2.23 kW
COP Tj = Tbiv
2.49
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.90 kW
1.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.46 kW
0.56 kW
Annual energy consumption Qhe
1220 kWh
1609 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
3.32 kW
El input
0.93 kW
1.11 kW
COP
4.32
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
127 %
Prated
2.36 kW
2.52 kW
SCOP
3.99
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
2.09 kW
2.23 kW
COP Tj = -7°C
2.49
2.12
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
1.24 kW
1.35 kW
COP Tj = +2°C
3.77
3.08
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
0.85 kW
0.86 kW
COP Tj = +7°C
5.49
4.18
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.90 kW
0.93 kW
COP Tj = 12°C
8.16
6.14
Cdh Tj = +12 °C
0.927
0.947
Pdh Tj = Tbiv
2.09 kW
2.23 kW
COP Tj = Tbiv
2.49
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.90 kW
1.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.46 kW
0.56 kW
Annual energy consumption Qhe
1220 kWh
1609 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
107 %
COP
2.68
Heating up time
1:44 h:min
Standby power input
38.7 W
Reference hot water temperature
49.5 °C
Mixed water at 40°C
146 l