Certificate holders

Subtype

DUAL CLIMA 19 HT PRO

Certificate Holder
Domusa Calefacción S.Coop.
Barrio San Esteban, S / N
20737 Errezil, Gipuzkoa
Spain
Registration number
037-1016-26
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
DUAL CLIMA 19 HT PRO
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,900 kg

Certification Date
10.07.2026
Testing basis
HP Keymark scheme rules rev. no. 15
Testing laboratory
SZU Brno, CZ
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

DUAL CLIMA 19 HT PRO
Configure model
Model name
DUAL CLIMA 19 HT PRO
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

19.52 kW

17.69 kW

El input

4.30 kW

5.60 kW

COP

4.54

3.16

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.65 kW

4.43 kW

Cooling capacity

13.85

18.62

EER

2.98

4.20

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

13.85 kW

18.62 kW

SEER

5.45

8.89

Pdc Tj = 35°C

13.85 kW

18.62 kW

EER Tj = 35°C

2.98

4.20

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

9.96 kW

13.68 kW

EER Tj = 30°C

4.17

6.73

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.19 kW

8.97 kW

EER Tj = 25°C

5.85

9.97

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.88 kW

4.24 kW

EER Tj = 20°C

9.14

15.57

Cdc Tj = 20 °C

0.900

0.900

Poff

9 W

9 W

PTO

15 W

15 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1524 kWh

1257 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

156 %

Prated

14.55 kW

14.68 kW

SCOP

5.20

3.98

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.87 kW

12.99 kW

COP Tj = -7°C

2.95

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.78 kW

7.54 kW

COP Tj = +2°C

5.16

3.92

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.53 kW

5.53 kW

COP Tj = +7°C

7.10

5.39

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.59 kW

6.55 kW

COP Tj = 12°C

8.71

6.57

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.87 kW

12.99 kW

COP Tj = Tbiv

2.95

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.37 kW

11.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

15 W

15 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.19 kW

3.57 kW

Annual energy consumption Qhe

5831 kWh

7703 kWh

DUAL CLIMA 19 HTT PRO
Configure model
Model name
DUAL CLIMA 19 HTT PRO
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

19.52 kW

17.69 kW

El input

4.30 kW

5.60 kW

COP

4.54

3.16

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.65 kW

4.43 kW

Cooling capacity

13.85

18.62

EER

2.98

4.20

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

13.85 kW

18.62 kW

SEER

5.45

8.89

Pdc Tj = 35°C

13.85 kW

18.62 kW

EER Tj = 35°C

2.98

4.20

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

9.96 kW

13.68 kW

EER Tj = 30°C

4.17

6.73

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.19 kW

8.97 kW

EER Tj = 25°C

5.85

9.97

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.88 kW

4.24 kW

EER Tj = 20°C

9.14

15.57

Cdc Tj = 20 °C

0.900

0.900

Poff

9 W

9 W

PTO

15 W

15 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1524 kWh

1257 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

156 %

Prated

14.55 kW

14.68 kW

SCOP

5.20

3.98

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.87 kW

12.99 kW

COP Tj = -7°C

2.95

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.78 kW

7.54 kW

COP Tj = +2°C

5.16

3.92

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.53 kW

5.53 kW

COP Tj = +7°C

7.10

5.39

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.59 kW

6.55 kW

COP Tj = 12°C

8.71

6.57

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.87 kW

12.99 kW

COP Tj = Tbiv

2.95

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.37 kW

11.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

15 W

15 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.18 kW

3.57 kW

Annual energy consumption Qhe

5831 kWh

7703 kWh