Certificate holders

Subtype

MONOBLOC ACTIVE 2 AOWD 17X

Certificate Holder
Eurofred S.A.
Marqués de Sentmenat, 97
08029 Barcelona
Spain
Registration number
041-K010-22
Certification Body
BRE
Subtype title
MONOBLOC ACTIVE 2 AOWD 17X
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,400 kg

Certification Date
17.06.2026
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AOWD-2--MB-AT17
Configure model
Model name
AOWD-2--MB-AT17
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.98 kW

17.09 kW

El input

4.02 kW

5.90 kW

COP

4.22

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

141 %

Prated

16.66 kW

17.07 kW

SCOP

4.65

3.61

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

14.74 kW

15.10 kW

COP Tj = -7°C

2.76

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.98 kW

9.37 kW

COP Tj = +2°C

4.52

3.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.82 kW

6.02 kW

COP Tj = +7°C

6.43

4.98

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.06 kW

5.80 kW

COP Tj = 12°C

8.11

6.41

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.74 kW

15.10 kW

COP Tj = Tbiv

2.76

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.05 kW

15.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

12 W

12 W

PSB

11 W

11 W

PCK

86 W

86 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

2.03 kW

Annual energy consumption Qhe

7404 kWh

9777 kWh

AOWD-2--MB-AT17T
Configure model
Model name
AOWD-2--MB-AT17T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.02 kW

16.92 kW

El input

4.03 kW

5.57 kW

COP

4.23

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

142 %

Prated

16.71 kW

16.62 kW

SCOP

4.64

3.62

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

14.78 kW

14.70 kW

COP Tj = -7°C

2.85

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.16 kW

9.09 kW

COP Tj = +2°C

4.49

3.54

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.80 kW

5.76 kW

COP Tj = +7°C

6.27

4.87

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.04 kW

5.86 kW

COP Tj = 12°C

8.36

6.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.78 kW

14.70 kW

COP Tj = Tbiv

2.85

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.57 kW

14.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

88 W

88 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.14 kW

2.57 kW

Annual energy consumption Qhe

7440 kWh

9486 kWh