Certificate holders

Subtype

MONOBLOC ACTIVE 2 AOWD 4X 6X

Certificate Holder
Eurofred S.A.
Marqués de Sentmenat, 97
08029 Barcelona
Spain
Registration number
041-K010-20
Certification Body
BRE
Subtype title
MONOBLOC ACTIVE 2 AOWD 4X 6X
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,650 kg

Certification Date
17.06.2026
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AOWD-2--MB-AT4
Configure model
Model name
AOWD-2--MB-AT4
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.07 kW

4.14 kW

El input

0.85 kW

1.40 kW

COP

4.79

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

54 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

132 %

Prated

4.45 kW

4.47 kW

SCOP

4.83

3.36

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

3.94 kW

3.95 kW

COP Tj = -7°C

3.10

2.23

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.55 kW

2.57 kW

COP Tj = +2°C

4.87

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.01 kW

1.75 kW

COP Tj = +7°C

6.59

4.16

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.29 kW

2.19 kW

COP Tj = 12°C

7.21

6.13

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.94 kW

3.95 kW

COP Tj = Tbiv

3.10

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

4.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

0.36 kW

Annual energy consumption Qhe

1903 kWh

2744 kWh

AOWD-2--MB-AT6
Configure model
Model name
AOWD-2--MB-AT6
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

6.95 kW

El input

1.46 kW

2.31 kW

COP

4.78

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

138 %

Prated

7.01 kW

6.64 kW

SCOP

4.78

3.51

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

6.20 kW

5.87 kW

COP Tj = -7°C

2.93

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.78 kW

3.71 kW

COP Tj = +2°C

4.59

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.49 kW

2.42 kW

COP Tj = +7°C

6.75

4.69

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.49 kW

2.29 kW

COP Tj = 12°C

8.37

6.72

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.20 kW

5.87 kW

COP Tj = Tbiv

2.93

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.69 kW

5.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.33 kW

1.60 kW

Annual energy consumption Qhe

3033 kWh

3904 kWh