Solax Air to Water Heat Pump Alture Series 4 5 6kW

Certificate Holder
SolaX Power Network Technology (Zhejiang) Co., Ltd.
No.278, Shizhu Road, Chengnan Sub-district
311599 Tonglu County, Hangzhou, Zhejiang China
China
Registration number
011-1W1298
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Solax Air to Water Heat Pump Alture Series 4 5 6kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,740 kg

Certification Date
16.06.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 3

Models

ALT04-SF0
Configure model
Model name
ALT04-SF0
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.60 kW

4.65 kW

El input

0.87 kW

1.37 kW

COP

5.30

3.40

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

186 %

Prated

4.51 kW

4.39 kW

SCOP

6.56

4.73

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.51 kW

4.39 kW

COP Tj = +2°C

4.22

2.81

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.92 kW

2.94 kW

COP Tj = +7°C

6.54

4.36

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.10 kW

3.01 kW

COP Tj = 12°C

7.70

5.90

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

4.51 kW

4.39 kW

COP Tj = Tbiv

4.22

2.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.51 kW

4.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

919 kWh

1240 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

136 %

Prated

4.41 kW

4.32 kW

SCOP

4.58

3.48

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.65 kW

2.64 kW

COP Tj = -7°C

4.07

2.87

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.43 kW

2.31 kW

COP Tj = +2°C

5.64

4.39

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

2.85 kW

2.75 kW

COP Tj = +7°C

6.74

5.25

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

3.15 kW

3.07 kW

COP Tj = 12°C

8.11

6.54

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

3.60 kW

3.53 kW

COP Tj = Tbiv

2.70

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.65 kW

3.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.76 kW

0.99 kW

Annual energy consumption Qhe

2371 kWh

3057 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.60

3.53

COP Tj = -15°C (if TOL<-20°C)

2.70

2.12

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

155 %

Prated

4.21 kW

4.29 kW

SCOP

5.25

3.96

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.75 kW

3.80 kW

COP Tj = -7°C

3.47

2.50

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.43 kW

2.34 kW

COP Tj = +2°C

5.58

4.07

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.76 kW

2.70 kW

COP Tj = +7°C

6.14

4.92

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.11 kW

2.97 kW

COP Tj = 12°C

7.54

5.96

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

4.21 kW

4.29 kW

COP Tj = Tbiv

2.81

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.21 kW

4.29 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

2.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1658 kWh

2240 kWh

ALT05-SF0
Configure model
Model name
ALT05-SF0
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.30 kW

5.55 kW

El input

1.04 kW

1.68 kW

COP

5.10

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

258 %

188 %

Prated

5.00 kW

5.00 kW

SCOP

6.53

4.78

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.90

2.66

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.21 kW

3.24 kW

COP Tj = +7°C

6.07

4.38

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

3.12 kW

3.02 kW

COP Tj = 12°C

8.18

5.99

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.90

2.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.90

2.66

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1024 kWh

1398 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

139 %

Prated

5.00 kW

5.00 kW

SCOP

4.62

3.56

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.17 kW

3.07 kW

COP Tj = -7°C

4.00

2.89

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.43 kW

2.36 kW

COP Tj = +2°C

5.81

4.53

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

2.85 kW

2.76 kW

COP Tj = +7°C

6.80

5.58

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.16 kW

3.08 kW

COP Tj = 12°C

8.24

6.63

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

4.08 kW

4.08 kW

COP Tj = Tbiv

2.63

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.11 kW

3.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.07

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.89 kW

1.18 kW

Annual energy consumption Qhe

2670 kWh

3460 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.08

4.08

COP Tj = -15°C (if TOL<-20°C)

2.63

2.08

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

152 %

Prated

5.00 kW

5.00 kW

SCOP

5.12

3.88

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.41 kW

4.43 kW

COP Tj = -7°C

3.12

2.33

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.75 kW

2.71 kW

COP Tj = +2°C

5.43

3.92

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.77 kW

2.69 kW

COP Tj = +7°C

6.19

5.02

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

3.10 kW

3.03 kW

COP Tj = 12°C

7.49

6.15

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.68

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2019 kWh

2666 kWh

ALT06-SF0
Configure model
Model name
ALT06-SF0
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.25 kW

6.45 kW

El input

1.25 kW

2.01 kW

COP

5.00

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

248 %

192 %

Prated

6.00 kW

6.00 kW

SCOP

6.28

4.88

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.00 kW

6.00 kW

COP Tj = +2°C

3.72

2.58

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.90 kW

3.80 kW

COP Tj = +7°C

5.54

4.35

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.15 kW

3.03 kW

COP Tj = 12°C

8.09

6.23

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

6.00 kW

6.00 kW

COP Tj = Tbiv

3.72

2.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.72

2.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1276 kWh

1644 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

140 %

Prated

6.00 kW

6.00 kW

SCOP

4.66

3.58

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.65 kW

3.55 kW

COP Tj = -7°C

3.95

2.84

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.52 kW

2.38 kW

COP Tj = +2°C

6.02

4.65

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

2.86 kW

2.78 kW

COP Tj = +7°C

6.87

5.70

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.17 kW

3.10 kW

COP Tj = 12°C

8.33

6.72

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.54

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.42 kW

4.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.01

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.58 kW

1.73 kW

Annual energy consumption Qhe

3178 kWh

4126 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.54

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201 %

157 %

Prated

6.00 kW

6.00 kW

SCOP

5.10

4.00

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.31 kW

5.31 kW

COP Tj = -7°C

2.93

2.24

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.22 kW

3.23 kW

COP Tj = +2°C

5.44

4.11

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.77 kW

2.72 kW

COP Tj = +7°C

6.24

5.23

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

3.14 kW

2.98 kW

COP Tj = 12°C

7.71

6.63

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

5.31 kW

5.31 kW

COP Tj = Tbiv

2.93

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.68 kW

5.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

11 W

11 W

PTO

19 W

19 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

0.80 kW

Annual energy consumption Qhe

2433 kWh

3105 kWh