Certificate holders

Subtype

ATRIA R290 12 14 16kW

Certificate Holder
TOYOTOMI CO., LTD
5-17
467-0855 Nagoya
Japan
Registration number
011-1W1293
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ATRIA R290 12 14 16kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,250 kg

Certification Date
16.06.2026
Testing basis
HP KEYMARK certification scheme rules V15
Testing laboratory
SGS-CSTC Standards Technical Services Co., Ltd. Shunde Branch, CN
Generate PDF Export model CSV
  • Number of models 12

Models

TAMUSG12/3R290
Configure model
Model name
TAMUSG12/3R290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

3.76 kW

COP

4.80

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

193 %

Prated

12.20 kW

12.10 kW

SCOP

6.83

4.90

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.10 kW

12.10 kW

COP Tj = +2°C

3.26

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.80 kW

7.80 kW

COP Tj = +7°C

5.82

4.21

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.60 kW

3.50 kW

COP Tj = 12°C

9.06

6.30

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.80 kW

7.80 kW

COP Tj = Tbiv

5.82

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.10 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

2384 kWh

3294 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

140 %

Prated

12.20 kW

12.40 kW

SCOP

4.38

3.58

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.30 kW

7.40 kW

COP Tj = -7°C

3.52

2.89

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

4.60 kW

COP Tj = +2°C

5.38

4.28

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.20 kW

3.00 kW

COP Tj = +7°C

7.58

5.86

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

8.49

7.27

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.90 kW

10.10 kW

COP Tj = Tbiv

2.61

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.50 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.70 kW

3.40 kW

Annual energy consumption Qhe

6834 kWh

8569 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.90

10.10

COP Tj = -15°C (if TOL<-20°C)

2.61

2.22

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

148 %

Prated

12.20 kW

11.90 kW

SCOP

4.78

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

10.60 kW

COP Tj = -7°C

2.71

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.80 kW

6.70 kW

COP Tj = +2°C

4.54

3.62

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

7.03

5.47

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.70 kW

4.00 kW

COP Tj = 12°C

8.98

7.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.80 kW

10.60 kW

COP Tj = Tbiv

2.71

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

10.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

1.60 kW

Annual energy consumption Qhe

5262 kWh

6456 kWh

TAMUSG12/3R290EH9
Configure model
Model name
TAMUSG12/3R290EH9
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

3.76 kW

COP

4.80

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

193 %

Prated

12.20 kW

12.10 kW

SCOP

6.83

4.90

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.10 kW

12.10 kW

COP Tj = +2°C

3.26

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.80 kW

7.80 kW

COP Tj = +7°C

5.82

4.21

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.60 kW

3.50 kW

COP Tj = 12°C

9.06

6.30

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.80 kW

7.80 kW

COP Tj = Tbiv

5.82

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.10 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

2384 kWh

3294 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

140 %

Prated

12.20 kW

12.40 kW

SCOP

4.38

3.58

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.30 kW

7.40 kW

COP Tj = -7°C

3.52

2.89

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

4.60 kW

COP Tj = +2°C

5.38

4.28

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.20 kW

3.00 kW

COP Tj = +7°C

7.58

5.86

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

8.49

7.27

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.90 kW

10.10 kW

COP Tj = Tbiv

2.61

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.50 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.70 kW

3.40 kW

Annual energy consumption Qhe

6834 kWh

8569 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.90

10.10

COP Tj = -15°C (if TOL<-20°C)

2.61

2.22

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

148 %

Prated

12.20 kW

11.90 kW

SCOP

4.78

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

10.60 kW

COP Tj = -7°C

2.71

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.80 kW

6.70 kW

COP Tj = +2°C

4.54

3.62

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

7.03

5.47

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.70 kW

4.00 kW

COP Tj = 12°C

8.98

7.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.80 kW

10.60 kW

COP Tj = Tbiv

2.71

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

10.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

1.60 kW

Annual energy consumption Qhe

5262 kWh

6456 kWh

TAMUSG12/1R290
Configure model
Model name
TAMUSG12/1R290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

3.76 kW

COP

4.80

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

193 %

Prated

12.20 kW

12.10 kW

SCOP

6.83

4.90

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.10 kW

12.10 kW

COP Tj = +2°C

3.26

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.80 kW

7.80 kW

COP Tj = +7°C

5.82

4.21

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.60 kW

3.50 kW

COP Tj = 12°C

9.06

6.30

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.80 kW

7.80 kW

COP Tj = Tbiv

5.82

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.10 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

2384 kWh

3294 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

140 %

Prated

12.20 kW

12.40 kW

SCOP

4.38

3.58

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.30 kW

7.40 kW

COP Tj = -7°C

3.52

2.89

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

4.60 kW

COP Tj = +2°C

5.38

4.28

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.20 kW

3.00 kW

COP Tj = +7°C

7.58

5.86

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

8.49

7.27

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.90 kW

10.10 kW

COP Tj = Tbiv

2.61

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.50 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.70 kW

3.40 kW

Annual energy consumption Qhe

6834 kWh

8569 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.90

10.10

COP Tj = -15°C (if TOL<-20°C)

2.61

2.22

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

148 %

Prated

12.20 kW

11.90 kW

SCOP

4.78

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

10.60 kW

COP Tj = -7°C

2.71

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.80 kW

6.70 kW

COP Tj = +2°C

4.54

3.62

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

7.03

5.47

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.70 kW

4.00 kW

COP Tj = 12°C

8.98

7.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.80 kW

10.60 kW

COP Tj = Tbiv

2.71

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

10.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

1.60 kW

Annual energy consumption Qhe

5262 kWh

6456 kWh

TAMUSG12/1R290EH3
Configure model
Model name
TAMUSG12/1R290EH3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

3.76 kW

COP

4.80

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

193 %

Prated

12.20 kW

12.10 kW

SCOP

6.83

4.90

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.10 kW

12.10 kW

COP Tj = +2°C

3.26

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.80 kW

7.80 kW

COP Tj = +7°C

5.82

4.21

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.60 kW

3.50 kW

COP Tj = 12°C

9.06

6.30

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.80 kW

7.80 kW

COP Tj = Tbiv

5.82

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.10 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.26

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

2384 kWh

3294 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

140 %

Prated

12.20 kW

12.40 kW

SCOP

4.38

3.58

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.30 kW

7.40 kW

COP Tj = -7°C

3.52

2.89

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

4.60 kW

COP Tj = +2°C

5.38

4.28

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.20 kW

3.00 kW

COP Tj = +7°C

7.58

5.86

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

8.49

7.27

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.90 kW

10.10 kW

COP Tj = Tbiv

2.61

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.50 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.70 kW

3.40 kW

Annual energy consumption Qhe

6834 kWh

8569 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.90

10.10

COP Tj = -15°C (if TOL<-20°C)

2.61

2.22

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

148 %

Prated

12.20 kW

11.90 kW

SCOP

4.78

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

10.60 kW

COP Tj = -7°C

2.71

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.80 kW

6.70 kW

COP Tj = +2°C

4.54

3.62

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

7.03

5.47

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.70 kW

4.00 kW

COP Tj = 12°C

8.98

7.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.80 kW

10.60 kW

COP Tj = Tbiv

2.71

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

10.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

1.60 kW

Annual energy consumption Qhe

5262 kWh

6456 kWh

TAMUSG14/3R290
Configure model
Model name
TAMUSG14/3R290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.05 kW

4.52 kW

COP

4.59

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

260 %

197 %

Prated

13.30 kW

13.90 kW

SCOP

6.58

5.00

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.00 kW

13.90 kW

COP Tj = +2°C

3.18

2.33

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.50 kW

8.90 kW

COP Tj = +7°C

5.75

4.15

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.80 kW

4.20 kW

COP Tj = 12°C

8.63

6.78

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.50 kW

8.90 kW

COP Tj = Tbiv

5.75

4.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

13.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.18

2.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.00 kW

Annual energy consumption Qhe

2690 kWh

3708 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

136 %

Prated

14.40 kW

13.10 kW

SCOP

4.25

3.48

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.80 kW

8.10 kW

COP Tj = -7°C

3.45

2.95

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.90 kW

COP Tj = +2°C

5.15

4.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.60 kW

3.00 kW

COP Tj = +7°C

7.54

5.66

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.10 kW

COP Tj = 12°C

8.49

7.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.80 kW

10.70 kW

COP Tj = Tbiv

2.52

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.03

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.80 kW

3.80 kW

Annual energy consumption Qhe

8357 kWh

9279 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.80

10.70

COP Tj = -15°C (if TOL<-20°C)

2.52

2.14

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

146 %

Prated

14.30 kW

13.00 kW

SCOP

4.65

3.73

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.60 kW

11.50 kW

COP Tj = -7°C

2.54

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.40 kW

7.10 kW

COP Tj = +2°C

4.37

3.56

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.90 kW

4.40 kW

COP Tj = +7°C

7.08

5.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.40 kW

4.00 kW

COP Tj = 12°C

9.63

7.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.60 kW

11.50 kW

COP Tj = Tbiv

2.54

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.90 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

2.00 kW

Annual energy consumption Qhe

6348 kWh

7157 kWh

TAMUSG14/3R290EH9
Configure model
Model name
TAMUSG14/3R290EH9
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.05 kW

4.52 kW

COP

4.59

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

260 %

197 %

Prated

13.30 kW

13.90 kW

SCOP

6.58

5.00

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.00 kW

13.90 kW

COP Tj = +2°C

3.18

2.33

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.50 kW

8.90 kW

COP Tj = +7°C

5.75

4.15

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.80 kW

4.20 kW

COP Tj = 12°C

8.63

6.78

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.50 kW

8.90 kW

COP Tj = Tbiv

5.75

4.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

13.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.18

2.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.00 kW

Annual energy consumption Qhe

2690 kWh

3708 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

136 %

Prated

14.40 kW

13.10 kW

SCOP

4.25

3.48

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.80 kW

8.10 kW

COP Tj = -7°C

3.45

2.95

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.90 kW

COP Tj = +2°C

5.15

4.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.60 kW

3.00 kW

COP Tj = +7°C

7.54

5.66

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.10 kW

COP Tj = 12°C

8.49

7.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.80 kW

10.70 kW

COP Tj = Tbiv

2.52

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.03

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.80 kW

3.80 kW

Annual energy consumption Qhe

8357 kWh

9279 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.80

10.70

COP Tj = -15°C (if TOL<-20°C)

2.52

2.14

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

146 %

Prated

14.30 kW

13.00 kW

SCOP

4.65

3.73

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.60 kW

11.50 kW

COP Tj = -7°C

2.54

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.40 kW

7.10 kW

COP Tj = +2°C

4.37

3.56

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.90 kW

4.40 kW

COP Tj = +7°C

7.08

5.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.40 kW

4.00 kW

COP Tj = 12°C

9.63

7.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.60 kW

11.50 kW

COP Tj = Tbiv

2.54

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.90 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

2.00 kW

Annual energy consumption Qhe

6348 kWh

7157 kWh

TAMUSG14/1R290
Configure model
Model name
TAMUSG14/1R290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.05 kW

4.52 kW

COP

4.59

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

260 %

197 %

Prated

13.30 kW

13.90 kW

SCOP

6.58

5.00

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.00 kW

13.90 kW

COP Tj = +2°C

3.18

2.33

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.50 kW

8.90 kW

COP Tj = +7°C

5.75

4.15

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.80 kW

4.20 kW

COP Tj = 12°C

8.63

6.78

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.50 kW

8.90 kW

COP Tj = Tbiv

5.75

4.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

13.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.18

2.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.00 kW

Annual energy consumption Qhe

2690 kWh

3708 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

136 %

Prated

14.40 kW

13.10 kW

SCOP

4.25

3.48

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.80 kW

8.10 kW

COP Tj = -7°C

3.45

2.95

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.90 kW

COP Tj = +2°C

5.15

4.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.60 kW

3.00 kW

COP Tj = +7°C

7.54

5.66

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.10 kW

COP Tj = 12°C

8.49

7.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.80 kW

10.70 kW

COP Tj = Tbiv

2.52

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.03

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.80 kW

3.80 kW

Annual energy consumption Qhe

8357 kWh

9279 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.80

10.70

COP Tj = -15°C (if TOL<-20°C)

2.52

2.14

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

146 %

Prated

14.30 kW

13.00 kW

SCOP

4.65

3.73

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.60 kW

11.50 kW

COP Tj = -7°C

2.54

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.40 kW

7.10 kW

COP Tj = +2°C

4.37

3.56

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.90 kW

4.40 kW

COP Tj = +7°C

7.08

5.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.40 kW

4.00 kW

COP Tj = 12°C

9.63

7.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.60 kW

11.50 kW

COP Tj = Tbiv

2.54

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.90 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

2.00 kW

Annual energy consumption Qhe

6348 kWh

7157 kWh

TAMUSG14/1R290EH3
Configure model
Model name
TAMUSG14/1R290EH3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.05 kW

4.52 kW

COP

4.59

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

260 %

197 %

Prated

13.30 kW

13.90 kW

SCOP

6.58

5.00

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.00 kW

13.90 kW

COP Tj = +2°C

3.18

2.33

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.50 kW

8.90 kW

COP Tj = +7°C

5.75

4.15

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.80 kW

4.20 kW

COP Tj = 12°C

8.63

6.78

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.50 kW

8.90 kW

COP Tj = Tbiv

5.75

4.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

13.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.18

2.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.00 kW

Annual energy consumption Qhe

2690 kWh

3708 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

136 %

Prated

14.40 kW

13.10 kW

SCOP

4.25

3.48

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.80 kW

8.10 kW

COP Tj = -7°C

3.45

2.95

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.20 kW

4.90 kW

COP Tj = +2°C

5.15

4.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.60 kW

3.00 kW

COP Tj = +7°C

7.54

5.66

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.10 kW

COP Tj = 12°C

8.49

7.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.80 kW

10.70 kW

COP Tj = Tbiv

2.52

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.03

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.80 kW

3.80 kW

Annual energy consumption Qhe

8357 kWh

9279 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.80

10.70

COP Tj = -15°C (if TOL<-20°C)

2.52

2.14

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

146 %

Prated

14.30 kW

13.00 kW

SCOP

4.65

3.73

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.60 kW

11.50 kW

COP Tj = -7°C

2.54

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.40 kW

7.10 kW

COP Tj = +2°C

4.37

3.56

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.90 kW

4.40 kW

COP Tj = +7°C

7.08

5.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.40 kW

4.00 kW

COP Tj = 12°C

9.63

7.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.60 kW

11.50 kW

COP Tj = Tbiv

2.54

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.90 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

2.00 kW

Annual energy consumption Qhe

6348 kWh

7157 kWh

TAMUSG16/3R290
Configure model
Model name
TAMUSG16/3R290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.00 kW

15.00 kW

El input

3.40 kW

5.20 kW

COP

4.41

2.88

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

248 %

195 %

Prated

15.40 kW

15.00 kW

SCOP

6.28

4.95

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.90 kW

14.80 kW

COP Tj = +2°C

2.85

2.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.90 kW

9.60 kW

COP Tj = +7°C

5.50

4.09

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.40 kW

4.40 kW

COP Tj = 12°C

8.33

6.76

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.90 kW

9.60 kW

COP Tj = Tbiv

5.50

4.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.90 kW

14.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

0.20 kW

Annual energy consumption Qhe

3265 kWh

4048 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

135 %

Prated

15.00 kW

14.80 kW

SCOP

4.10

3.45

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.30 kW

9.00 kW

COP Tj = -7°C

3.39

2.80

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.40 kW

5.40 kW

COP Tj = +2°C

4.85

4.11

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.60 kW

3.60 kW

COP Tj = +7°C

7.22

5.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.10 kW

COP Tj = 12°C

8.49

7.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.20 kW

12.00 kW

COP Tj = Tbiv

2.46

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.20 kW

4.80 kW

Annual energy consumption Qhe

9013 kWh

10575 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.20

12.00

COP Tj = -15°C (if TOL<-20°C)

2.46

2.11

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

143 %

Prated

15.40 kW

14.20 kW

SCOP

4.53

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.60 kW

12.60 kW

COP Tj = -7°C

2.46

2.11

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.30 kW

8.30 kW

COP Tj = +2°C

4.20

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.30 kW

5.10 kW

COP Tj = +7°C

7.06

5.44

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.20 kW

COP Tj = 12°C

9.36

7.23

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.60 kW

12.60 kW

COP Tj = Tbiv

2.46

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.30 kW

12.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

1.50 kW

Annual energy consumption Qhe

7024 kWh

8051 kWh

TAMUSG16/3R290EH9
Configure model
Model name
TAMUSG16/3R290EH9
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.00 kW

15.00 kW

El input

3.40 kW

5.20 kW

COP

4.41

2.88

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

248 %

195 %

Prated

15.40 kW

15.00 kW

SCOP

6.28

4.95

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.90 kW

14.80 kW

COP Tj = +2°C

2.85

2.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.90 kW

9.60 kW

COP Tj = +7°C

5.50

4.09

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.40 kW

4.40 kW

COP Tj = 12°C

8.33

6.76

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.90 kW

9.60 kW

COP Tj = Tbiv

5.50

4.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.90 kW

14.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

0.20 kW

Annual energy consumption Qhe

3265 kWh

4048 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

135 %

Prated

15.00 kW

14.80 kW

SCOP

4.10

3.45

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.30 kW

9.00 kW

COP Tj = -7°C

3.39

2.80

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.40 kW

5.40 kW

COP Tj = +2°C

4.85

4.11

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.60 kW

3.60 kW

COP Tj = +7°C

7.22

5.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.10 kW

COP Tj = 12°C

8.49

7.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.20 kW

12.00 kW

COP Tj = Tbiv

2.46

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.20 kW

4.80 kW

Annual energy consumption Qhe

9013 kWh

10575 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.20

12.00

COP Tj = -15°C (if TOL<-20°C)

2.46

2.11

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

143 %

Prated

15.40 kW

14.20 kW

SCOP

4.53

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.60 kW

12.60 kW

COP Tj = -7°C

2.46

2.11

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.30 kW

8.30 kW

COP Tj = +2°C

4.20

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.30 kW

5.10 kW

COP Tj = +7°C

7.06

5.44

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.20 kW

COP Tj = 12°C

9.36

7.23

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.60 kW

12.60 kW

COP Tj = Tbiv

2.46

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.30 kW

12.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

1.50 kW

Annual energy consumption Qhe

7024 kWh

8051 kWh

TAMUSG16/1R290
Configure model
Model name
TAMUSG16/1R290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.00 kW

15.00 kW

El input

3.40 kW

5.20 kW

COP

4.41

2.88

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

248 %

195 %

Prated

15.40 kW

15.00 kW

SCOP

6.28

4.95

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.90 kW

14.80 kW

COP Tj = +2°C

2.85

2.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.90 kW

9.60 kW

COP Tj = +7°C

5.50

4.09

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.40 kW

4.40 kW

COP Tj = 12°C

8.33

6.76

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.90 kW

9.60 kW

COP Tj = Tbiv

5.50

4.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.90 kW

14.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

0.20 kW

Annual energy consumption Qhe

3265 kWh

4048 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

135 %

Prated

15.00 kW

14.80 kW

SCOP

4.10

3.45

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.30 kW

9.00 kW

COP Tj = -7°C

3.39

2.80

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.40 kW

5.40 kW

COP Tj = +2°C

4.85

4.11

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.60 kW

3.60 kW

COP Tj = +7°C

7.22

5.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.10 kW

COP Tj = 12°C

8.49

7.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.20 kW

12.00 kW

COP Tj = Tbiv

2.46

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.20 kW

4.80 kW

Annual energy consumption Qhe

9013 kWh

10575 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.20

12.00

COP Tj = -15°C (if TOL<-20°C)

2.46

2.11

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

143 %

Prated

15.40 kW

14.20 kW

SCOP

4.53

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.60 kW

12.60 kW

COP Tj = -7°C

2.46

2.11

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.30 kW

8.30 kW

COP Tj = +2°C

4.20

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.30 kW

5.10 kW

COP Tj = +7°C

7.06

5.44

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.20 kW

COP Tj = 12°C

9.36

7.23

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.60 kW

12.60 kW

COP Tj = Tbiv

2.46

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.30 kW

12.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

1.50 kW

Annual energy consumption Qhe

7024 kWh

8051 kWh

TAMUSG16/1R290EH3
Configure model
Model name
TAMUSG16/1R290EH3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.00 kW

15.00 kW

El input

3.40 kW

5.20 kW

COP

4.41

2.88

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

248 %

195 %

Prated

15.40 kW

15.00 kW

SCOP

6.28

4.95

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.90 kW

14.80 kW

COP Tj = +2°C

2.85

2.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.90 kW

9.60 kW

COP Tj = +7°C

5.50

4.09

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.40 kW

4.40 kW

COP Tj = 12°C

8.33

6.76

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.90 kW

9.60 kW

COP Tj = Tbiv

5.50

4.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.90 kW

14.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

0.20 kW

Annual energy consumption Qhe

3265 kWh

4048 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

135 %

Prated

15.00 kW

14.80 kW

SCOP

4.10

3.45

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.30 kW

9.00 kW

COP Tj = -7°C

3.39

2.80

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.40 kW

5.40 kW

COP Tj = +2°C

4.85

4.11

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.60 kW

3.60 kW

COP Tj = +7°C

7.22

5.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.10 kW

COP Tj = 12°C

8.49

7.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.20 kW

12.00 kW

COP Tj = Tbiv

2.46

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.20 kW

4.80 kW

Annual energy consumption Qhe

9013 kWh

10575 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.20

12.00

COP Tj = -15°C (if TOL<-20°C)

2.46

2.11

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

143 %

Prated

15.40 kW

14.20 kW

SCOP

4.53

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.60 kW

12.60 kW

COP Tj = -7°C

2.46

2.11

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.30 kW

8.30 kW

COP Tj = +2°C

4.20

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.30 kW

5.10 kW

COP Tj = +7°C

7.06

5.44

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.20 kW

COP Tj = 12°C

9.36

7.23

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.60 kW

12.60 kW

COP Tj = Tbiv

2.46

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.30 kW

12.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

1.50 kW

Annual energy consumption Qhe

7024 kWh

8051 kWh