Certificate holders

Subtype

40 INV 2T R290

Certificate Holder
FROST ITALY S.R.L.
Via lago di Trasimeno , 46
35015 Schio
Italy
Registration number
037-1011-26
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
40 INV 2T R290
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

4,400 kg

Certification Date
31.07.2026
Testing basis
HP KEYMARK certification scheme rules rev. no. 15
Testing laboratory
SZU Brno, CZ
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Aurax Mini Ni 40 2T
Configure model
Model name
Aurax Mini Ni 40 2T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

31.90 kW

30.80 kW

Heating capacity

31.90

30.80

El input

7.61 kW

10.30 kW

COP

4.19

2.99

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

8.06 kW

8.66 kW

Cooling capacity

21.94

30.30

EER

2.47

2.94

EN 12102-1

+7°C/+12°C

+18°C/+23°C

Sound power level outdoor

75 dB(A)

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

24.90 kW

34.30 kW

SEER

2.90

3.76

Pdc Tj = 35°C

24.90 kW

34.30 kW

EER Tj = 35°C

2.87

3.59

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

18.35 kW

25.27 kW

EER Tj = 30°C

2.85

3.64

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

11.79 kW

16.25 kW

EER Tj = 25°C

2.86

3.67

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

5.24 kW

7.22 kW

EER Tj = 20°C

3.13

4.18

Cdc Tj = 20 °C

0.962

0.900

Poff

29 W

29 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Annual energy consumption Qce

5149 kWh

5476 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.60 kW

17.40 kW

ηs

204 %

164 %

Prated

18.60 kW

17.40 kW

SCOP

5.17

4.17

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.40 kW

15.40 kW

COP Tj = -7°C

2.95

2.23

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.80 kW

11.10 kW

COP Tj = +2°C

5.13

4.17

Cdh Tj = +2 °C

0.966

0.971

Pdh Tj = +7°C

13.70 kW

13.20 kW

COP Tj = +7°C

7.21

5.92

Cdh Tj = +7 °C

0.960

0.965

Pdh Tj = 12°C

15.90 kW

15.50 kW

COP Tj = 12°C

10.80

8.96

Cdh Tj = +12 °C

0.948

0.956

Pdh Tj = Tbiv

18.60 kW

17.40 kW

COP Tj = Tbiv

2.53

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.60 kW

17.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

29 W

29 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Backup Heater

0.00 kW

0.00 kW

Annual energy consumption Qhe

7426 kWh

8627 kWh

TRIBUS NATURAL H 40 INV 2P R290
Configure model
Model name
TRIBUS NATURAL H 40 INV 2P R290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

31.90 kW

30.80 kW

Heating capacity

31.90

30.80

El input

7.61 kW

10.30 kW

COP

4.19

2.99

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

8.06 kW

8.66 kW

Cooling capacity

21.94

30.30

EER

2.47

2.94

EN 12102-1

+7°C/+12°C

+18°C/+23°C

Sound power level outdoor

75 dB(A)

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

24.90 kW

34.30 kW

SEER

2.90

3.76

Pdc Tj = 35°C

24.90 kW

34.30 kW

EER Tj = 35°C

2.87

3.59

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

18.35 kW

25.27 kW

EER Tj = 30°C

2.85

3.64

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

11.79 kW

16.25 kW

EER Tj = 25°C

2.86

3.67

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

5.24 kW

7.22 kW

EER Tj = 20°C

3.13

4.18

Cdc Tj = 20 °C

0.962

0.900

Poff

29 W

29 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Annual energy consumption Qce

5149 kWh

5476 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.60 kW

17.40 kW

ηs

204 %

164 %

Prated

18.60 kW

17.40 kW

SCOP

5.17

4.17

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.40 kW

15.40 kW

COP Tj = -7°C

2.95

2.23

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.80 kW

11.10 kW

COP Tj = +2°C

5.13

4.17

Cdh Tj = +2 °C

0.966

0.971

Pdh Tj = +7°C

13.70 kW

13.20 kW

COP Tj = +7°C

7.21

5.92

Cdh Tj = +7 °C

0.960

0.965

Pdh Tj = 12°C

15.90 kW

15.50 kW

COP Tj = 12°C

10.80

8.96

Cdh Tj = +12 °C

0.948

0.956

Pdh Tj = Tbiv

18.60 kW

17.40 kW

COP Tj = Tbiv

2.53

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.60 kW

17.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

29 W

29 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Backup Heater

0.00 kW

0.00 kW

Annual energy consumption Qhe

7426 kWh

8627 kWh