Certificate holders

Subtype

Monoblock Heat Pump R290 12/14/16 kW

Certificate Holder
Xinlei Compressor Co., Ltd.
No.8 Chaoping Street, East New District
317500 Wenling City, Zhejiang Province

Registration number
011-1W1286
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monoblock Heat Pump R290 12/14/16 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,700 kg

Certification Date
16.06.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 6

Models

XLHT-12LR9HP
Configure model
Model name
XLHT-12LR9HP
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.42 kW

3.63 kW

COP

4.95

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

153 %

Prated

12.08 kW

12.07 kW

SCOP

4.99

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.68 kW

10.68 kW

COP Tj = -7°C

3.30

2.51

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.80 kW

7.69 kW

COP Tj = +2°C

4.55

3.66

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.61 kW

4.90 kW

COP Tj = +7°C

7.00

5.32

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

4.93 kW

4.82 kW

COP Tj = 12°C

10.07

7.90

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

10.68 kW

10.68 kW

COP Tj = Tbiv

3.30

2.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.13 kW

9.69 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.01

2.22

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

80 °C

80 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

48 W

48 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.95 kW

2.38 kW

Annual energy consumption Qhe

4999 kWh

6412 kWh

XLHT-14LR9HP
Configure model
Model name
XLHT-14LR9HP
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.31 kW

COP

4.80

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

153 %

Prated

14.52 kW

14.06 kW

SCOP

4.85

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.84 kW

12.44 kW

COP Tj = -7°C

3.00

2.46

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.61 kW

7.70 kW

COP Tj = +2°C

4.47

3.63

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.08 kW

4.90 kW

COP Tj = +7°C

6.92

5.31

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

4.93 kW

4.81 kW

COP Tj = 12°C

10.06

7.89

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

12.84 kW

12.44 kW

COP Tj = Tbiv

3.00

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

11.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.94

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

80 °C

80 °C

Poff

15 W

15 W

PTO

17 W

17 W

PSB

15 W

15 W

PCK

53 W

53 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.28 kW

2.57 kW

Annual energy consumption Qhe

6178 kWh

7466 kWh

XLHT-16LR9HP
Configure model
Model name
XLHT-16LR9HP
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.40 kW

5.04 kW

COP

4.70

3.17

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

153 %

Prated

14.90 kW

15.01 kW

SCOP

4.71

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.19 kW

13.28 kW

COP Tj = -7°C

2.88

2.42

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.66 kW

8.18 kW

COP Tj = +2°C

4.28

3.66

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.59 kW

5.41 kW

COP Tj = +7°C

6.92

5.31

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.40 kW

5.30 kW

COP Tj = 12°C

10.00

7.84

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

13.19 kW

13.28 kW

COP Tj = Tbiv

2.88

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.99 kW

12.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.89

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

80 °C

80 °C

Poff

16 W

16 W

PTO

17 W

17 W

PSB

16 W

16 W

PCK

54 W

54 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.91 kW

3.00 kW

Annual energy consumption Qhe

6538 kWh

7965 kWh

XLHT-12LR9XP
Configure model
Model name
XLHT-12LR9XP
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.42 kW

3.63 kW

COP

4.95

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

153 %

Prated

12.11 kW

12.10 kW

SCOP

5.02

3.91

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.71 kW

10.71 kW

COP Tj = -7°C

3.32

2.52

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.81 kW

7.70 kW

COP Tj = +2°C

4.59

3.63

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.61 kW

4.91 kW

COP Tj = +7°C

7.03

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

4.94 kW

4.82 kW

COP Tj = 12°C

10.11

7.93

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

10.71 kW

10.71 kW

COP Tj = Tbiv

3.32

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.13 kW

9.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.01

2.22

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

15 W

15 W

PTO

17 W

17 W

PSB

15 W

15 W

PCK

53 W

53 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.98 kW

2.40 kW

Annual energy consumption Qhe

4978 kWh

6400 kWh

XLHT-14LR9XP
Configure model
Model name
XLHT-14LR9XP
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.31 kW

COP

4.80

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

153 %

Prated

14.57 kW

14.13 kW

SCOP

4.88

3.91

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.89 kW

12.50 kW

COP Tj = -7°C

3.02

2.47

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.63 kW

7.72 kW

COP Tj = +2°C

4.49

3.64

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.10 kW

4.92 kW

COP Tj = +7°C

6.96

5.35

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

4.95 kW

4.83 kW

COP Tj = 12°C

10.13

7.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

12.89 kW

12.50 kW

COP Tj = Tbiv

3.02

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

11.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.95

2.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

80 °C

80 °C

Poff

16 W

16 W

PTO

17 W

17 W

PSB

16 W

16 W

PCK

54 W

54 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.31 kW

2.62 kW

Annual energy consumption Qhe

6173 kWh

7467 kWh

XLHT-16LR9XP
Configure model
Model name
XLHT-16LR9XP
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.40 kW

5.04 kW

COP

4.70

3.17

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

153 %

Prated

14.93 kW

15.03 kW

SCOP

4.71

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.20 kW

13.30 kW

COP Tj = -7°C

2.88

2.43

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.66 kW

8.18 kW

COP Tj = +2°C

4.27

3.66

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.59 kW

5.41 kW

COP Tj = +7°C

6.92

5.30

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.40 kW

5.30 kW

COP Tj = 12°C

9.99

7.83

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

13.20 kW

13.30 kW

COP Tj = Tbiv

2.88

2.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.99 kW

12.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.89

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

80 °C

80 °C

Poff

16 W

16 W

PTO

17 W

17 W

PSB

16 W

16 W

PCK

53 W

53 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.94 kW

3.02 kW

Annual energy consumption Qhe

6549 kWh

7976 kWh