Certificate holders

Subtype

AURUM R290 Series 12 14 16 kW

Certificate Holder
EAS Electric Smart Technology SL
Camino La Sierra, s/n Parcela 11 Redován
03370 Alicante
Spain
Registration number
ICIM-PDC-000426
Certification Body
ICIM S.p.A.
Subtype title
AURUM R290 Series 12 14 16 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,250 kg

Certification Date
29.05.2026
Testing basis
V12
Testing laboratory
Bureau Veritas Consumer Products Services (Guangzhou) Co., Ltd, Science City Branch
Generate PDF Export model CSV
  • Number of models 3

Models

AURUM120VMT
Configure model
Model name
AURUM120VMT
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.5 kW

3.87 kW

COP

4.8

3.1

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

174 %

Prated

11.7 kW

12.4 kW

SCOP

5.9

4.45

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.58 kW

11.41 kW

COP Tj = +2°C

3.3

2.55

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

7.57 kW

7.85 kW

COP Tj = +7°C

5.78

3.99

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.17 kW

5.47 kW

COP Tj = 12°C

6.98

5.9

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

7.57 kW

7.85 kW

COP Tj = Tbiv

5.78

3.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.58 kW

11.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.3

2.55

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.12 kW

0.99 kW

Annual energy consumption Qhe

2651 kWh

3724 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

127 %

Prated

11.5 kW

10.8 kW

SCOP

4.13

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.11 kW

6.76 kW

COP Tj = -7°C

3.47

2.72

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

4.33 kW

4.14 kW

COP Tj = +2°C

5.18

4.05

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.08 kW

5 kW

COP Tj = +7°C

6.46

5.15

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.15 kW

5.01 kW

COP Tj = 12°C

6.84

5.66

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

9.39 kW

8.84 kW

COP Tj = Tbiv

2.49

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.7 kW

6.84 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.52

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.8 kW

3.96 kW

Annual energy consumption Qhe

6869 kWh

8197 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.39

8.84

COP Tj = -15°C (if TOL<-20°C)

2.49

1.98

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

141 %

Prated

12.1 kW

12 kW

SCOP

4.67

3.62

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.75 kW

10.58 kW

COP Tj = -7°C

2.78

2.23

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

6.73 kW

6.59 kW

COP Tj = +2°C

4.55

3.52

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.23 kW

4.78 kW

COP Tj = +7°C

6.89

4.99

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.34 kW

5.59 kW

COP Tj = 12°C

7.41

6.41

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

10.75 kW

10.58 kW

COP Tj = Tbiv

2.78

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.77 kW

10.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.05

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.33 kW

1.95 kW

Annual energy consumption Qhe

5352 kWh

6843 kWh

AURUM160VMT
Configure model
Model name
AURUM160VMT
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15 kW

15 kW

El input

3.41 kW

5.26 kW

COP

4.4

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

238 %

181 %

Prated

14.3 kW

14.9 kW

SCOP

6.05

4.62

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.82 kW

13.47 kW

COP Tj = +2°C

3.18

2.48

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

9.17 kW

9.58 kW

COP Tj = +7°C

5.82

4.04

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.34 kW

5.64 kW

COP Tj = 12°C

7.33

6.31

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

9.17 kW

9.58 kW

COP Tj = Tbiv

5.82

4.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.82 kW

13.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.18

2.48

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.48 kW

1.43 kW

Annual energy consumption Qhe

3159 kWh

4306 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

128 %

Prated

14.6 kW

13.9 kW

SCOP

4.08

3.29

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.89 kW

8.3 kW

COP Tj = -7°C

3.25

2.7

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5.87 kW

5.18 kW

COP Tj = +2°C

5.22

4.03

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.24 kW

5.17 kW

COP Tj = +7°C

6.67

5.44

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.32 kW

5.23 kW

COP Tj = 12°C

7.26

6.07

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

11.91 kW

11.32 kW

COP Tj = Tbiv

2.41

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.06 kW

9.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.02

1.56

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.54 kW

4.83 kW

Annual energy consumption Qhe

8813 kWh

10408 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.91

11.32

COP Tj = -15°C (if TOL<-20°C)

2.41

1.97

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

139 %

Prated

14.7 kW

14.4 kW

SCOP

4.59

3.57

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.04 kW

12.78 kW

COP Tj = -7°C

2.54

2.05

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8 kW

7.96 kW

COP Tj = +2°C

4.4

3.44

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.26 kW

4.78 kW

COP Tj = +7°C

7.12

5.13

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.28 kW

5.72 kW

COP Tj = 12°C

7.56

6.58

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.04 kW

12.78 kW

COP Tj = Tbiv

2.54

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.81 kW

12.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.94

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.89 kW

1.86 kW

Annual energy consumption Qhe

6617 kWh

8349 kWh

AURUM160YMT
Configure model
Model name
AURUM160YMT
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15 kW

15 kW

El input

3.41 kW

5.26 kW

COP

4.4

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

238 %

181 %

Prated

14.3 kW

14.9 kW

SCOP

6.05

4.62

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.82 kW

13.47 kW

COP Tj = +2°C

3.18

2.48

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

9.17 kW

9.58 kW

COP Tj = +7°C

5.82

4.04

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.34 kW

5.64 kW

COP Tj = 12°C

7.33

6.31

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

9.17 kW

9.58 kW

COP Tj = Tbiv

5.82

4.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.82 kW

13.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.18

2.48

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.48 kW

1.43 kW

Annual energy consumption Qhe

3159 kWh

4306 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

128 %

Prated

14.6 kW

13.9 kW

SCOP

4.08

3.29

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.89 kW

8.3 kW

COP Tj = -7°C

3.25

2.7

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5.87 kW

5.18 kW

COP Tj = +2°C

5.22

4.03

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.24 kW

5.17 kW

COP Tj = +7°C

6.67

5.44

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.32 kW

5.23 kW

COP Tj = 12°C

7.26

6.07

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

11.91 kW

11.32 kW

COP Tj = Tbiv

2.41

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.06 kW

9.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.02

1.56

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.54 kW

4.83 kW

Annual energy consumption Qhe

8813 kWh

10408 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.91

11.32

COP Tj = -15°C (if TOL<-20°C)

2.41

1.97

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

139 %

Prated

14.7 kW

14.4 kW

SCOP

4.59

3.57

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.04 kW

12.78 kW

COP Tj = -7°C

2.54

2.05

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8 kW

7.96 kW

COP Tj = +2°C

4.4

3.44

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.26 kW

4.78 kW

COP Tj = +7°C

7.12

5.13

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.28 kW

5.72 kW

COP Tj = 12°C

7.56

6.58

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.04 kW

12.78 kW

COP Tj = Tbiv

2.54

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.81 kW

12.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.94

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.89 kW

1.86 kW

Annual energy consumption Qhe

6617 kWh

8349 kWh