Certificate holders

Subtype

Hydronis R290 AIO Series 8-10KW

Certificate Holder
3I TECHNOLOGIES

75016 Paris
France
Registration number
011-1W1266
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Hydronis R290 AIO Series 8-10KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,850 kg

Certification Date
22.05.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 2

Models

Indoor unit AW-A1M01-D190M- A443GZ1 and outdoor unit AW- A1E01-H080M-A440GZ1
Configure model
Model name
Indoor unit AW-A1M01-D190M- A443GZ1 and outdoor unit AW- A1E01-H080M-A440GZ1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

7.80 kW

El input

1.68 kW

2.36 kW

COP

5.00

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

272 %

173 %

Prated

8.10 kW

7.60 kW

SCOP

6.88

4.40

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.80 kW

7.30 kW

COP Tj = +2°C

3.98

2.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.21 kW

4.89 kW

COP Tj = +7°C

5.88

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.63 kW

2.17 kW

COP Tj = 12°C

9.36

6.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.21 kW

4.89 kW

COP Tj = Tbiv

5.88

3.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

7.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.98

2.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

1573 kWh

2304 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

152 %

Prated

8.10 kW

6.60 kW

SCOP

5.03

3.88

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.17 kW

5.84 kW

COP Tj = -7°C

3.23

2.43

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.36 kW

3.55 kW

COP Tj = +2°C

4.93

3.83

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.80 kW

2.28 kW

COP Tj = +7°C

6.81

4.98

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.15 kW

2.99 kW

COP Tj = 12°C

10.10

7.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.17 kW

5.84 kW

COP Tj = Tbiv

3.23

2.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.44 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.23

2.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.66 kW

1.69 kW

Annual energy consumption Qhe

3246 kWh

3510 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118 %

COP

3.04

Heating up time

1:11 h:min

Standby power input

43.0 W

Reference hot water temperature

48.4 °C

Mixed water at 40°C

210 l

Indoor unit AW-A1M01-D190M- A443GZ1 and outdoor unit AW- A1E01-H100M-A440GZ1
Configure model
Model name
Indoor unit AW-A1M01-D190M- A443GZ1 and outdoor unit AW- A1E01-H100M-A440GZ1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

9.50 kW

El input

2.08 kW

3.25 kW

COP

4.80

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

267 %

177 %

Prated

8.60 kW

8.60 kW

SCOP

6.75

4.50

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.20 kW

8.20 kW

COP Tj = +2°C

3.84

2.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.53 kW

5.53 kW

COP Tj = +7°C

5.85

3.93

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.76 kW

2.46 kW

COP Tj = 12°C

9.14

5.82

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.53 kW

5.53 kW

COP Tj = Tbiv

5.85

3.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.20 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.84

2.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.40 kW

Annual energy consumption Qhe

1701 kWh

2545 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

152 %

Prated

9.20 kW

7.70 kW

SCOP

5.15

3.88

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.14 kW

6.81 kW

COP Tj = -7°C

3.10

2.43

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.95 kW

4.15 kW

COP Tj = +2°C

5.02

3.82

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.18 kW

2.67 kW

COP Tj = +7°C

6.50

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.76 kW

3.39 kW

COP Tj = 12°C

10.55

7.45

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.14 kW

6.81 kW

COP Tj = Tbiv

3.10

2.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

5.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.47 kW

Annual energy consumption Qhe

3690 kWh

4150 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118 %

COP

3.04

Heating up time

1:11 h:min

Standby power input

43.0 W

Reference hot water temperature

48.4 °C

Mixed water at 40°C

210 l