Certificate holders

Subtype

Hydronis R290 Plus Series 12-16KW

Certificate Holder
3I TECHNOLOGIES

75016 Paris
France
Registration number
011-1W1265
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Hydronis R290 Plus Series 12-16KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,350 kg

Certification Date
22.05.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 12

Models

AW-MBT01-H120T-A449GZ1
Configure model
Model name
AW-MBT01-H120T-A449GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.45 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

174 %

Prated

11.10 kW

12.50 kW

SCOP

6.42

4.42

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.90 kW

12.30 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.82

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.61 kW

3.57 kW

COP Tj = 12°C

8.30

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.82

3.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.20 kW

Annual energy consumption Qhe

2308 kWh

3775 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

12.20 kW

12.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.50

3.67

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.60

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.69 kW

4.12 kW

COP Tj = 12°C

9.38

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5314 kWh

6477 kWh

AW-MBT01-H140T-A449GZ1
Configure model
Model name
AW-MBT01-H140T-A449GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.38 kW

COP

4.80

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

178 %

Prated

12.10 kW

13.70 kW

SCOP

6.55

4.52

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.60 kW

COP Tj = +2°C

3.44

2.18

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.23 kW

4.08 kW

COP Tj = 12°C

8.43

5.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

13.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.10 kW

Annual energy consumption Qhe

2463 kWh

4037 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.52

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

6.40

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.68 kW

2.15 kW

COP Tj = 12°C

10.00

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6317 kWh

7563 kWh

AW-MBT01-H160T-A449GZ1
Configure model
Model name
AW-MBT01-H160T-A449GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

15.10 kW

El input

3.21 kW

4.79 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

176 %

Prated

13.10 kW

13.80 kW

SCOP

6.22

4.47

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.97 kW

13.67 kW

COP Tj = +2°C

3.35

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.42 kW

8.87 kW

COP Tj = +7°C

5.31

3.80

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.29 kW

3.94 kW

COP Tj = 12°C

8.23

5.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.42 kW

8.87 kW

COP Tj = Tbiv

5.31

3.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.97 kW

13.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

2812 kWh

4118 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

15.50 kW

14.00 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.38 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.54 kW

COP Tj = +2°C

4.48

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

4.85 kW

COP Tj = +7°C

6.73

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.38 kW

4.43 kW

COP Tj = 12°C

10.05

8.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.38 kW

COP Tj = Tbiv

3.01

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

3.50 kW

Annual energy consumption Qhe

6604 kWh

7563 kWh

AW-MBT01-H120T-A440GZ1
Configure model
Model name
AW-MBT01-H120T-A440GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.45 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

174 %

Prated

11.10 kW

12.50 kW

SCOP

6.42

4.42

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.90 kW

12.30 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.82

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.61 kW

3.57 kW

COP Tj = 12°C

8.30

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.82

3.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.20 kW

Annual energy consumption Qhe

2308 kWh

3775 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

12.20 kW

12.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.50

3.67

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.60

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.69 kW

4.12 kW

COP Tj = 12°C

9.38

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5314 kWh

6477 kWh

AW-MBT01-H140T-A440GZ1
Configure model
Model name
AW-MBT01-H140T-A440GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.38 kW

COP

4.80

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

178 %

Prated

12.10 kW

13.70 kW

SCOP

6.55

4.52

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.60 kW

COP Tj = +2°C

3.44

2.18

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.23 kW

4.08 kW

COP Tj = 12°C

8.43

5.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

13.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.10 kW

Annual energy consumption Qhe

2463 kWh

4037 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.52

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

6.40

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.68 kW

2.15 kW

COP Tj = 12°C

10.00

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6317 kWh

7563 kWh

AW-MBT01-H160T-A440GZ1
Configure model
Model name
AW-MBT01-H160T-A440GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

15.10 kW

El input

3.21 kW

4.79 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

176 %

Prated

13.10 kW

13.80 kW

SCOP

6.22

4.47

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.97 kW

13.67 kW

COP Tj = +2°C

3.35

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.42 kW

8.87 kW

COP Tj = +7°C

5.31

3.80

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.29 kW

3.94 kW

COP Tj = 12°C

8.23

5.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.42 kW

8.87 kW

COP Tj = Tbiv

5.31

3.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.97 kW

13.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

2812 kWh

4118 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

15.50 kW

14.00 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.38 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.54 kW

COP Tj = +2°C

4.48

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

4.85 kW

COP Tj = +7°C

6.73

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.38 kW

4.43 kW

COP Tj = 12°C

10.05

8.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.38 kW

COP Tj = Tbiv

3.01

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

3.50 kW

Annual energy consumption Qhe

6604 kWh

7563 kWh

AW-MBT01-H120M-A443GZ1
Configure model
Model name
AW-MBT01-H120M-A443GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.45 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

174 %

Prated

11.10 kW

12.50 kW

SCOP

6.42

4.42

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.90 kW

12.30 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.82

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.61 kW

3.57 kW

COP Tj = 12°C

8.30

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.82

3.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.20 kW

Annual energy consumption Qhe

2308 kWh

3775 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

12.20 kW

12.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.50

3.67

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.60

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.69 kW

4.12 kW

COP Tj = 12°C

9.38

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5314 kWh

6477 kWh

AW-MBT01-H140M-A443GZ1
Configure model
Model name
AW-MBT01-H140M-A443GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.38 kW

COP

4.80

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

178 %

Prated

12.10 kW

13.70 kW

SCOP

6.55

4.52

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.60 kW

COP Tj = +2°C

3.44

2.18

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.23 kW

4.08 kW

COP Tj = 12°C

8.43

5.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

13.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.10 kW

Annual energy consumption Qhe

2463 kWh

4037 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.52

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

6.40

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.68 kW

2.15 kW

COP Tj = 12°C

10.00

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6317 kWh

7563 kWh

AW-MBT01-H160M-A443GZ1
Configure model
Model name
AW-MBT01-H160M-A443GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

15.10 kW

El input

3.21 kW

4.79 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

176 %

Prated

13.10 kW

13.80 kW

SCOP

6.22

4.47

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.97 kW

13.67 kW

COP Tj = +2°C

3.35

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.42 kW

8.87 kW

COP Tj = +7°C

5.31

3.80

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.29 kW

3.94 kW

COP Tj = 12°C

8.23

5.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.42 kW

8.87 kW

COP Tj = Tbiv

5.31

3.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.97 kW

13.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

2812 kWh

4118 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

15.50 kW

14.00 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.38 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.54 kW

COP Tj = +2°C

4.48

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

4.85 kW

COP Tj = +7°C

6.73

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.38 kW

4.43 kW

COP Tj = 12°C

10.05

8.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.38 kW

COP Tj = Tbiv

3.01

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

3.50 kW

Annual energy consumption Qhe

6604 kWh

7563 kWh

AW-MBT01-H120M-A440GZ1
Configure model
Model name
AW-MBT01-H120M-A440GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.45 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

254 %

174 %

Prated

11.10 kW

12.50 kW

SCOP

6.42

4.42

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.90 kW

12.30 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.82

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.61 kW

3.57 kW

COP Tj = 12°C

8.30

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.82

3.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.20 kW

Annual energy consumption Qhe

2308 kWh

3775 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

12.20 kW

12.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.50

3.67

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.60

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.69 kW

4.12 kW

COP Tj = 12°C

9.38

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5314 kWh

6477 kWh

AW-MBT01-H140M-A440GZ1
Configure model
Model name
AW-MBT01-H140M-A440GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.38 kW

COP

4.80

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

178 %

Prated

12.10 kW

13.70 kW

SCOP

6.55

4.52

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.60 kW

COP Tj = +2°C

3.44

2.18

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.23 kW

4.08 kW

COP Tj = 12°C

8.43

5.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

13.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.10 kW

Annual energy consumption Qhe

2463 kWh

4037 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.52

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

6.40

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.68 kW

2.15 kW

COP Tj = 12°C

10.00

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6317 kWh

7563 kWh

AW-MBT01-H160M-A440GZ1
Configure model
Model name
AW-MBT01-H160M-A440GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

15.10 kW

El input

3.21 kW

4.79 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

176 %

Prated

13.10 kW

13.80 kW

SCOP

6.22

4.47

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.97 kW

13.67 kW

COP Tj = +2°C

3.35

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.42 kW

8.87 kW

COP Tj = +7°C

5.31

3.80

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.29 kW

3.94 kW

COP Tj = 12°C

8.23

5.88

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.42 kW

8.87 kW

COP Tj = Tbiv

5.31

3.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.97 kW

13.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

2812 kWh

4118 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

15.50 kW

14.00 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.38 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.54 kW

COP Tj = +2°C

4.48

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

4.85 kW

COP Tj = +7°C

6.73

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.38 kW

4.43 kW

COP Tj = 12°C

10.05

8.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.38 kW

COP Tj = Tbiv

3.01

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

3.50 kW

Annual energy consumption Qhe

6604 kWh

7563 kWh