Certificate holders

Subtype

Hydronis R290 Plus Series 4-6KW

Certificate Holder
3I TECHNOLOGIES

75016 Paris
France
Registration number
011-1W1263
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Hydronis R290 Plus Series 4-6KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,550 kg

Certification Date
22.05.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 4

Models

AW-MBT01-H040M-A443GZ1
Configure model
Model name
AW-MBT01-H040M-A443GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.50 kW

4.60 kW

El input

0.87 kW

1.44 kW

COP

5.15

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

252 %

161 %

Prated

5.50 kW

5.00 kW

SCOP

6.37

4.10

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.37 kW

4.87 kW

COP Tj = +2°C

3.94

2.51

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.54 kW

3.21 kW

COP Tj = +7°C

5.82

3.62

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.57 kW

1.94 kW

COP Tj = 12°C

7.91

5.35

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.21 kW

COP Tj = Tbiv

5.82

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.37 kW

4.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.94

2.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

1151 kWh

1627 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

5.50 kW

5.50 kW

SCOP

4.95

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.87 kW

4.87 kW

COP Tj = -7°C

2.96

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.96 kW

2.96 kW

COP Tj = +2°C

4.84

3.75

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.90 kW

1.90 kW

COP Tj = +7°C

6.46

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.02 kW

2.16 kW

COP Tj = 12°C

11.71

7.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.87 kW

4.87 kW

COP Tj = Tbiv

2.96

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.16 kW

0.00 kW

Annual energy consumption Qhe

2295 kWh

2950 kWh

AW-MBT01-H060M-A443GZ1
Configure model
Model name
AW-MBT01-H060M-A443GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.35 kW

6.40 kW

El input

1.27 kW

1.97 kW

COP

5.00

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

162 %

Prated

6.10 kW

5.10 kW

SCOP

6.47

4.12

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.85 kW

4.85 kW

COP Tj = +2°C

3.91

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.92 kW

3.28 kW

COP Tj = +7°C

5.89

3.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.93 kW

1.69 kW

COP Tj = 12°C

8.31

5.42

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.92 kW

3.28 kW

COP Tj = Tbiv

5.89

3.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.91

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.25 kW

0.25 kW

Annual energy consumption Qhe

1258 kWh

1652 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

151 %

Prated

6.80 kW

6.30 kW

SCOP

4.92

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.57 kW

COP Tj = -7°C

2.85

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.66 kW

3.39 kW

COP Tj = +2°C

4.98

3.72

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.35 kW

2.18 kW

COP Tj = +7°C

6.38

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.17 kW

2.07 kW

COP Tj = 12°C

9.67

7.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.02 kW

5.57 kW

COP Tj = Tbiv

2.85

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.42 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

0.30 kW

Annual energy consumption Qhe

2818 kWh

3381 kWh

AW-MBT01-H040M-A440GZ1
Configure model
Model name
AW-MBT01-H040M-A440GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.50 kW

4.60 kW

El input

0.87 kW

1.44 kW

COP

5.15

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

252 %

161 %

Prated

5.50 kW

5.00 kW

SCOP

6.37

4.10

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.37 kW

4.87 kW

COP Tj = +2°C

3.94

2.51

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.54 kW

3.21 kW

COP Tj = +7°C

5.82

3.62

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.57 kW

1.94 kW

COP Tj = 12°C

7.91

5.35

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.21 kW

COP Tj = Tbiv

5.82

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.37 kW

4.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.94

2.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.13 kW

Annual energy consumption Qhe

1151 kWh

1627 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

5.50 kW

5.50 kW

SCOP

4.95

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.87 kW

4.87 kW

COP Tj = -7°C

2.96

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.96 kW

2.96 kW

COP Tj = +2°C

4.84

3.75

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.90 kW

1.90 kW

COP Tj = +7°C

6.46

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.02 kW

2.16 kW

COP Tj = 12°C

11.71

7.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.87 kW

4.87 kW

COP Tj = Tbiv

2.96

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.16 kW

0.00 kW

Annual energy consumption Qhe

2295 kWh

2950 kWh

AW-MBT01-H060M-A440GZ1
Configure model
Model name
AW-MBT01-H060M-A440GZ1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.35 kW

6.40 kW

El input

1.27 kW

1.97 kW

COP

5.00

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

162 %

Prated

6.10 kW

5.10 kW

SCOP

6.47

4.12

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.85 kW

4.85 kW

COP Tj = +2°C

3.91

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.92 kW

3.28 kW

COP Tj = +7°C

5.89

3.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.93 kW

1.69 kW

COP Tj = 12°C

8.31

5.42

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.92 kW

3.28 kW

COP Tj = Tbiv

5.89

3.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

4.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.91

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.25 kW

0.25 kW

Annual energy consumption Qhe

1258 kWh

1652 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

151 %

Prated

6.80 kW

6.30 kW

SCOP

4.92

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.57 kW

COP Tj = -7°C

2.85

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.66 kW

3.39 kW

COP Tj = +2°C

4.98

3.72

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.35 kW

2.18 kW

COP Tj = +7°C

6.38

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.17 kW

2.07 kW

COP Tj = 12°C

9.67

7.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.02 kW

5.57 kW

COP Tj = Tbiv

2.85

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.42 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

0.30 kW

Annual energy consumption Qhe

2818 kWh

3381 kWh