Certificate holders

Subtype

Mikrofill RenewAIR R290 RA-ASHP-R290-009

Certificate Holder
Dutypoint Ltd
Quedgeley West Business Park, Brtistol Road
Gl24 PA Gloucester
United Kingdom
Registration number
ICIM-PDC-000418
Certification Body
ICIM S.p.A.
Subtype title
Mikrofill RenewAIR R290 RA-ASHP-R290-009
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,750 kg

Certification Date
07.09.2026
Testing basis
V12
Generate PDF Export model CSV
  • Number of models 1

Models

Mikrofill RenewAIR R290 RA-ASHP-R290-009
Configure model
Model name
Mikrofill RenewAIR R290 RA-ASHP-R290-009
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.69 kW

8.95 kW

El input

2.05 kW

2.80 kW

COP

4.72

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.77 kW

Cooling capacity

8.57

EER

3.09

EN 14825

+7°C/+12°C

Pdesignc

8.57 kW

SEER

5.41

Pdc Tj = 35°C

8.57 kW

EER Tj = 35°C

3.09

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

6.15 kW

EER Tj = 30°C

4.41

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.72 kW

EER Tj = 25°C

6.06

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.95 kW

EER Tj = 20°C

8.87

Cdc Tj = 20 °C

0.934

Poff

22 W

PTO

0 W

PSB

28 W

PCK

0 W

Annual energy consumption Qce

950 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

9.00 kW

9.00 kW

SCOP

5.07

3.92

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.40 kW

7.60 kW

COP Tj = -7°C

3.35

2.08

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.00 kW

5.10 kW

COP Tj = +2°C

4.86

3.80

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.30 kW

3.80 kW

COP Tj = +7°C

6.82

5.71

Cdh Tj = +7 °C

0.974

0.981

Pdh Tj = 12°C

2.70 kW

3.30 kW

COP Tj = 12°C

7.87

7.37

Cdh Tj = +12 °C

0.964

0.972

Pdh Tj = Tbiv

8.40 kW

7.60 kW

COP Tj = Tbiv

3.35

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.10 kW

1.30 kW

Annual energy consumption Qhe

3866 kWh

4520 kWh