0,750 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.69 kW
8.95 kW
El input
2.05 kW
2.80 kW
COP
4.72
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
2.77 kW
Cooling capacity
8.57
EER
3.09
EN 14825
+7°C/+12°C
Pdesignc
8.57 kW
SEER
5.41
Pdc Tj = 35°C
8.57 kW
EER Tj = 35°C
3.09
Cdc Tj = 35 °C
1.000
Pdc Tj = 30°C
6.15 kW
EER Tj = 30°C
4.41
Cdc Tj = 30 °C
1.000
Pdc Tj = 25°C
3.72 kW
EER Tj = 25°C
6.06
Cdc Tj = 25 °C
1.000
Pdc Tj = 20°C
2.95 kW
EER Tj = 20°C
8.87
Cdc Tj = 20 °C
0.934
Poff
22 W
PTO
0 W
PSB
28 W
PCK
0 W
Annual energy consumption Qce
950 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
154 %
Prated
9.00 kW
9.00 kW
SCOP
5.07
3.92
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.40 kW
7.60 kW
COP Tj = -7°C
3.35
2.08
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.00 kW
5.10 kW
COP Tj = +2°C
4.86
3.80
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.30 kW
3.80 kW
COP Tj = +7°C
6.82
5.71
Cdh Tj = +7 °C
0.974
0.981
Pdh Tj = 12°C
2.70 kW
3.30 kW
COP Tj = 12°C
7.87
7.37
Cdh Tj = +12 °C
0.964
0.972
Pdh Tj = Tbiv
8.40 kW
7.60 kW
COP Tj = Tbiv
3.35
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.90 kW
7.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.80
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
75 °C
75 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
1.30 kW
Annual energy consumption Qhe
3866 kWh
4520 kWh