2,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.14 kW
13.05 kW
El input
2.72 kW
3.99 kW
COP
4.83
3.28
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.64 kW
2.30 kW
Cooling capacity
10.07
10.10
EER
2.77
4.39
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
10.00 kW
10.00 kW
SEER
4.93
6.76
Pdc Tj = 35°C
10.07 kW
10.10 kW
EER Tj = 35°C
2.77
4.39
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
7.56 kW
7.34 kW
EER Tj = 30°C
4.11
5.84
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.90 kW
4.73 kW
EER Tj = 25°C
5.44
7.30
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.81 kW
3.84 kW
EER Tj = 20°C
6.43
8.23
Cdc Tj = 20 °C
0.980
0.980
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Annual energy consumption Qce
1250 kWh
921 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
41 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
293 %
204 %
Prated
12.40 kW
12.70 kW
SCOP
7.43
5.19
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.71 kW
11.97 kW
COP Tj = +2°C
3.68
2.61
Cdh Tj = +2 °C
0.998
0.998
Pdh Tj = +7°C
7.37 kW
7.78 kW
COP Tj = +7°C
6.43
4.31
Cdh Tj = +7 °C
0.993
0.996
Pdh Tj = 12°C
3.87 kW
3.74 kW
COP Tj = 12°C
9.44
6.84
Cdh Tj = +12 °C
0.981
0.985
Pdh Tj = Tbiv
11.71 kW
11.97 kW
COP Tj = Tbiv
3.68
2.61
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.71 kW
11.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.68
2.61
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.998
0.998
WTOL
75 °C
75 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2240 kWh
3283 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
41 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
151 %
Prated
12.00 kW
12.00 kW
SCOP
5.12
3.86
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.88 kW
7.01 kW
COP Tj = -7°C
4.12
3.13
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
4.19 kW
4.27 kW
COP Tj = +2°C
6.51
4.75
Cdh Tj = +2 °C
0.988
0.991
Pdh Tj = +7°C
3.46 kW
3.25 kW
COP Tj = +7°C
8.21
6.28
Cdh Tj = +7 °C
0.981
0.985
Pdh Tj = 12°C
3.96 kW
3.73 kW
COP Tj = 12°C
9.96
8.17
Cdh Tj = +12 °C
0.980
0.983
Pdh Tj = Tbiv
10.02 kW
10.05 kW
COP Tj = Tbiv
2.88
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.90 kW
8.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.33
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.998
0.998
WTOL
75 °C
75 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.10 kW
3.59 kW
Annual energy consumption Qhe
5783 kWh
7675 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.02
10.05
COP Tj = -15°C (if TOL<-20°C)
2.88
2.19
Cdh Tj = -15 °C
0.998
0.998
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
41 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
236 %
168 %
Prated
10.50 kW
10.50 kW
SCOP
5.97
4.29
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.64 kW
8.77 kW
COP Tj = -7°C
3.62
2.59
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
5.15 kW
5.33 kW
COP Tj = +2°C
5.80
4.15
Cdh Tj = +2 °C
0.991
0.994
Pdh Tj = +7°C
3.51 kW
3.40 kW
COP Tj = +7°C
7.93
5.62
Cdh Tj = +7 °C
0.982
0.987
Pdh Tj = 12°C
3.91 kW
3.69 kW
COP Tj = 12°C
9.80
7.60
Cdh Tj = +12 °C
0.980
0.984
Pdh Tj = Tbiv
9.60 kW
9.61 kW
COP Tj = Tbiv
3.16
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.60 kW
9.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.16
2.28
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
75 °C
75 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3636 kWh
5062 kWh