Certificate holders

Subtype

Aquarea Split 9-16 kW STD 260L (K Series)

Certificate Holder
Panasonic Marketing Europe GmbH
Hagenauer Strasse 43, Wiesbaden
65203 Wiesbaden
Germany
Registration number
011-1W1261
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquarea Split 9-16 kW STD 260L (K Series)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,600 kg

Certification Date
22.05.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
SZU Brno, CZ
Generate PDF Export model CSV
  • Number of models 9

Models

WH-ADC0912K9E83 / WH-UDZ09KE8
Configure model
Model name
WH-ADC0912K9E83 / WH-UDZ09KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.84 kW

3.03 kW

COP

4.90

2.97

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

8.80 kW

Cooling capacity

2.83

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.80 kW

5.90 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.00 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

10.00 kW

8.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.70 kW

4.80 kW

COP Tj = -7°C

3.44

2.80

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.80 kW

4.50 kW

COP Tj = +2°C

5.26

3.78

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.30 kW

COP Tj = +7°C

6.60

5.14

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.20 kW

COP Tj = 12°C

8.03

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.40 kW

6.50 kW

COP Tj = Tbiv

2.70

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

7.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

0.30 kW

Annual energy consumption Qhe

5725 kWh

6057 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.40

6.50

COP Tj = -15°C (if TOL<-20°C)

2.70

1.96

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.00 kW

8.00 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.90 kW

4.90 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.40 kW

5.10 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.10 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

94 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

WH-ADC0912K9E8AN3 / WH-UDZ09KE8
Configure model
Model name
WH-ADC0912K9E8AN3 / WH-UDZ09KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.84 kW

3.03 kW

COP

4.90

2.97

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

8.80 kW

Cooling capacity

2.83

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.80 kW

5.90 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.00 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

10.00 kW

8.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.70 kW

4.80 kW

COP Tj = -7°C

3.44

2.80

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.80 kW

4.50 kW

COP Tj = +2°C

5.26

3.78

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.30 kW

COP Tj = +7°C

6.60

5.14

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.20 kW

COP Tj = 12°C

8.03

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.40 kW

6.50 kW

COP Tj = Tbiv

2.70

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

7.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

0.30 kW

Annual energy consumption Qhe

5725 kWh

6057 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.40

6.50

COP Tj = -15°C (if TOL<-20°C)

2.70

1.96

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.00 kW

8.00 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.90 kW

4.90 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.40 kW

5.10 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.10 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

94 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

WH-ADC0912K9E83 / WH-UDZ12KE8
Configure model
Model name
WH-ADC0912K9E83 / WH-UDZ12KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.53 kW

4.05 kW

COP

4.78

2.96

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

10.70 kW

Cooling capacity

3.99

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.80 kW

5.90 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.00 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

9.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.70 kW

6.70 kW

COP Tj = -7°C

3.37

2.77

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.80 kW

4.30 kW

COP Tj = +2°C

5.32

3.73

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.30 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.10 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

7.30 kW

COP Tj = Tbiv

2.70

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.00 kW

Annual energy consumption Qhe

6289 kWh

6801 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.00

7.30

COP Tj = -15°C (if TOL<-20°C)

2.70

2.15

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

140 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.58

Tbiv

-10 °C

-3 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.60 kW

8.58 kW

COP Tj = -7°C

2.51

2.43

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.50 kW

6.08 kW

COP Tj = +2°C

4.53

3.62

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.12 kW

COP Tj = +7°C

6.18

4.95

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.40 kW

5.97 kW

COP Tj = 12°C

7.93

6.20

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.00 kW

8.66 kW

COP Tj = Tbiv

2.71

2.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

8.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

3.49 kW

Annual energy consumption Qhe

5416 kWh

6920 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

94 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

WH-ADC0912K9E8AN3 / WH-UDZ12KE8
Configure model
Model name
WH-ADC0912K9E8AN3 / WH-UDZ12KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.53 kW

4.05 kW

COP

4.78

2.96

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

10.70 kW

Cooling capacity

3.99

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.80 kW

5.90 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.00 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

9.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.70 kW

6.70 kW

COP Tj = -7°C

3.37

2.77

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.80 kW

4.30 kW

COP Tj = +2°C

5.32

3.73

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.30 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.10 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

7.30 kW

COP Tj = Tbiv

2.70

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.00 kW

Annual energy consumption Qhe

6289 kWh

6801 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.00

7.30

COP Tj = -15°C (if TOL<-20°C)

2.70

2.15

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

140 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.58

Tbiv

-10 °C

-3 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.60 kW

8.58 kW

COP Tj = -7°C

2.51

2.43

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.50 kW

6.08 kW

COP Tj = +2°C

4.53

3.62

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.12 kW

COP Tj = +7°C

6.18

4.95

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.40 kW

5.97 kW

COP Tj = 12°C

7.93

6.20

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.00 kW

8.66 kW

COP Tj = Tbiv

2.71

2.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

8.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

3.49 kW

Annual energy consumption Qhe

5416 kWh

6920 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

94 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

WH-ADC0912K6E53 / WH-UDZ12KE5
Configure model
Model name
WH-ADC0912K6E53 / WH-UDZ12KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.53 kW

4.05 kW

COP

4.78

2.96

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

10.70 kW

Cooling capacity

3.99

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.80 kW

5.90 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.00 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

9.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.70 kW

6.70 kW

COP Tj = -7°C

3.37

2.77

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.80 kW

4.30 kW

COP Tj = +2°C

5.32

3.73

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.30 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.10 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

7.30 kW

COP Tj = Tbiv

2.70

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.00 kW

Annual energy consumption Qhe

6289 kWh

6801 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.00

7.30

COP Tj = -15°C (if TOL<-20°C)

2.70

2.15

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

140 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.58

Tbiv

-10 °C

-3 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

8.58 kW

COP Tj = -7°C

3.04

2.43

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.70 kW

6.08 kW

COP Tj = +2°C

4.44

3.62

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.40 kW

5.12 kW

COP Tj = +7°C

5.80

4.95

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

5.97 kW

COP Tj = 12°C

6.81

6.20

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.00 kW

8.66 kW

COP Tj = Tbiv

2.90

2.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

8.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

3.49 kW

Annual energy consumption Qhe

5416 kWh

6920 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

96 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

WH-ADC0912K6E5UK3 / WH-UDZ12KE5
Configure model
Model name
WH-ADC0912K6E5UK3 / WH-UDZ12KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.53 kW

4.05 kW

COP

4.78

2.96

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

10.70 kW

Cooling capacity

3.99

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.80 kW

5.90 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.00 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

9.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.70 kW

6.70 kW

COP Tj = -7°C

3.37

2.77

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.80 kW

4.30 kW

COP Tj = +2°C

5.32

3.73

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.30 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.10 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

7.30 kW

COP Tj = Tbiv

2.70

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.00 kW

Annual energy consumption Qhe

6289 kWh

6801 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.00

7.30

COP Tj = -15°C (if TOL<-20°C)

2.70

2.15

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

140 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.58

Tbiv

-10 °C

-3 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

8.58 kW

COP Tj = -7°C

3.04

2.43

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.70 kW

6.08 kW

COP Tj = +2°C

4.44

3.62

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.40 kW

5.12 kW

COP Tj = +7°C

5.80

4.95

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

5.97 kW

COP Tj = 12°C

6.81

6.20

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.00 kW

8.66 kW

COP Tj = Tbiv

2.90

2.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

8.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

3.49 kW

Annual energy consumption Qhe

5416 kWh

6920 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

96 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

WH-ADC0912K6E5AN3 / WH-UDZ12KE5
Configure model
Model name
WH-ADC0912K6E5AN3 / WH-UDZ12KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.53 kW

4.05 kW

COP

4.78

2.96

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

10.70 kW

Cooling capacity

3.99

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.80 kW

5.90 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.00 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

9.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.70 kW

6.70 kW

COP Tj = -7°C

3.37

2.77

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.80 kW

4.30 kW

COP Tj = +2°C

5.32

3.73

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.30 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

6.10 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

7.30 kW

COP Tj = Tbiv

2.70

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.00 kW

Annual energy consumption Qhe

6289 kWh

6801 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.00

7.30

COP Tj = -15°C (if TOL<-20°C)

2.70

2.15

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

140 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.58

Tbiv

-10 °C

-3 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.80 kW

8.58 kW

COP Tj = -7°C

3.04

2.43

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.70 kW

6.08 kW

COP Tj = +2°C

4.44

3.62

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.40 kW

5.12 kW

COP Tj = +7°C

5.80

4.95

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.30 kW

5.97 kW

COP Tj = 12°C

6.81

6.20

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.00 kW

8.66 kW

COP Tj = Tbiv

2.90

2.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

8.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

3.49 kW

Annual energy consumption Qhe

5416 kWh

6920 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

96 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

WH-ADC16K6E53 / WH-UDZ16KE5
Configure model
Model name
WH-ADC16K6E53 / WH-UDZ16KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

14.70 kW

El input

3.71 kW

5.40 kW

COP

4.31

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

12.20 kW

Cooling capacity

4.55

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

12.00 kW

SEER

4.77

Pdc Tj = 35°C

12.00 kW

EER Tj = 35°C

2.65

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

8.84 kW

EER Tj = 30°C

3.67

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

5.68 kW

EER Tj = 25°C

5.58

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

4.88 kW

EER Tj = 20°C

7.08

Cdc Tj = 20 °C

1.000

Poff

1 W

PTO

10 W

PSB

9 W

PCK

0 W

Annual energy consumption Qce

881 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

169 %

Prated

13.00 kW

10.00 kW

SCOP

6.20

4.30

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.00 kW

10.00 kW

COP Tj = +2°C

3.00

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

8.40 kW

6.40 kW

COP Tj = +7°C

5.67

3.73

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.80 kW

5.70 kW

COP Tj = 12°C

7.57

5.41

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.00 kW

10.00 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2803 kWh

3104 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

121 %

Prated

12.00 kW

12.00 kW

SCOP

4.28

3.10

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.30 kW

7.30 kW

COP Tj = -7°C

3.63

2.62

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.40 kW

4.40 kW

COP Tj = +2°C

5.09

3.68

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.10 kW

4.90 kW

COP Tj = +7°C

6.31

4.61

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.80 kW

5.80 kW

COP Tj = 12°C

7.54

5.83

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.80 kW

9.80 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.00

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

3.50 kW

Annual energy consumption Qhe

6917 kWh

9556 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.80

9.80

COP Tj = -15°C (if TOL<-20°C)

2.64

1.89

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

133 %

Prated

13.00 kW

13.00 kW

SCOP

4.46

3.40

Tbiv

-7 °C

-3 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

9.50 kW

COP Tj = -7°C

2.63

2.31

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

7.00 kW

COP Tj = +2°C

4.26

3.32

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.10 kW

4.86 kW

COP Tj = +7°C

6.32

4.83

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.80 kW

5.71 kW

COP Tj = 12°C

7.78

6.15

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.50 kW

9.50 kW

COP Tj = Tbiv

2.63

2.49

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.90 kW

3.00 kW

Annual energy consumption Qhe

6018 kWh

7911 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

94 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

WH-ADC16K6E5AN3 / WH-UDZ16KE5
Configure model
Model name
WH-ADC16K6E5AN3 / WH-UDZ16KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

14.70 kW

El input

3.71 kW

5.40 kW

COP

4.31

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

12.20 kW

Cooling capacity

4.55

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

12.00 kW

SEER

4.77

Pdc Tj = 35°C

12.00 kW

EER Tj = 35°C

2.65

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

8.84 kW

EER Tj = 30°C

3.67

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

5.68 kW

EER Tj = 25°C

5.58

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

4.88 kW

EER Tj = 20°C

7.08

Cdc Tj = 20 °C

1.000

Poff

1 W

PTO

10 W

PSB

9 W

PCK

0 W

Annual energy consumption Qce

881 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

169 %

Prated

13.00 kW

10.00 kW

SCOP

6.20

4.30

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.00 kW

10.00 kW

COP Tj = +2°C

3.00

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

8.40 kW

6.40 kW

COP Tj = +7°C

5.67

3.73

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.80 kW

5.70 kW

COP Tj = 12°C

7.57

5.41

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.00 kW

10.00 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2803 kWh

3104 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

121 %

Prated

12.00 kW

12.00 kW

SCOP

4.28

3.10

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.30 kW

7.30 kW

COP Tj = -7°C

3.63

2.62

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.40 kW

4.40 kW

COP Tj = +2°C

5.09

3.68

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.10 kW

4.90 kW

COP Tj = +7°C

6.31

4.61

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.80 kW

5.80 kW

COP Tj = 12°C

7.54

5.83

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.80 kW

9.80 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.00

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

3.50 kW

Annual energy consumption Qhe

6917 kWh

9556 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.80

9.80

COP Tj = -15°C (if TOL<-20°C)

2.64

1.89

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

133 %

Prated

13.00 kW

13.00 kW

SCOP

4.46

3.40

Tbiv

-7 °C

-3 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

9.50 kW

COP Tj = -7°C

2.63

2.31

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

7.00 kW

COP Tj = +2°C

4.26

3.32

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.10 kW

4.86 kW

COP Tj = +7°C

6.32

4.83

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.80 kW

5.71 kW

COP Tj = 12°C

7.78

6.15

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.50 kW

9.50 kW

COP Tj = Tbiv

2.63

2.49

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.90 kW

3.00 kW

Annual energy consumption Qhe

6018 kWh

7911 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:06 h:min

Standby power input

31.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

94 %

COP

2.35

Heating up time

1:06 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.08

Heating up time

1:06 h:min

Standby power input

34.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

323 l