3,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
23.82 kW
24.00 kW
El input
4.71 kW
6.90 kW
COP
5.06
3.48
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210 %
161 %
Prated
23.94 kW
24.12 kW
SCOP
5.31
4.11
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
21.18 kW
21.34 kW
COP Tj = -7°C
3.42
2.65
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
13.13 kW
13.11 kW
COP Tj = +2°C
5.14
3.96
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.44 kW
8.47 kW
COP Tj = +7°C
6.89
5.33
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.72 kW
9.59 kW
COP Tj = 12°C
9.29
7.24
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
21.18 kW
21.34 kW
COP Tj = Tbiv
3.42
2.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
23.88 kW
23.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
2.35
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
80 °C
80 °C
Poff
21 W
21 W
PTO
21 W
21 W
PSB
21 W
21 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.06 kW
0.26 kW
Annual energy consumption Qhe
9309 kWh
12131 kWh