1,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.90 kW
11.97 kW
El input
2.50 kW
3.74 kW
COP
4.77
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
151 %
Prated
11.84 kW
11.74 kW
SCOP
5.10
3.85
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.47 kW
10.38 kW
COP Tj = -7°C
3.00
2.35
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.43 kW
6.34 kW
COP Tj = +2°C
4.95
3.68
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.24 kW
COP Tj = +7°C
6.90
5.19
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.85 kW
4.55 kW
COP Tj = 12°C
9.92
7.57
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.47 kW
10.38 kW
COP Tj = Tbiv
3.00
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.76 kW
11.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
80 °C
80 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
40 W
40 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.08 kW
0.06 kW
Annual energy consumption Qhe
4798 kWh
6304 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.90 kW
11.87 kW
El input
2.46 kW
3.66 kW
COP
4.84
3.24
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
151 %
Prated
11.76 kW
11.92 kW
SCOP
5.09
3.85
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
10.55 kW
COP Tj = -7°C
3.04
2.41
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.33 kW
6.48 kW
COP Tj = +2°C
4.94
3.72
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.28 kW
4.16 kW
COP Tj = +7°C
6.89
5.00
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.79 kW
4.43 kW
COP Tj = 12°C
9.84
7.17
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.40 kW
10.55 kW
COP Tj = Tbiv
3.04
2.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.73 kW
11.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
2.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
80 °C
80 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
40 W
40 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.03 kW
0.10 kW
Annual energy consumption Qhe
4769 kWh
6402 kWh