Certificate holders

Subtype

AURUM R290 Series 26 30 35 40kW

Certificate Holder
EAS Electric Smart Technology SL
Camino La Sierra, s/n Parcela 11 Redován
03370 Alicante
Spain
Registration number
041-K066-27
Certification Body
BRE
Subtype title
AURUM R290 Series 26 30 35 40kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

2,900 kg

Certification Date
06.05.2026
Testing basis
HP KEYMARK certification scheme rules rev. no.15
Testing laboratory
Intertek Testing Services Shenzhen LTD. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

AURUM260YMT
Configure model
Model name
AURUM260YMT
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

26.00 kW

26.00 kW

El input

5.45 kW

7.85 kW

COP

4.77

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259.80 %

194.80 %

Prated

26.00 kW

26.00 kW

SCOP

6.57

4.94

Tbiv

7.00 °C

7.00 °C

TOL

2.00 °C

2.00 °C

Pdh Tj = +2°C

26.00 kW

26.00 kW

COP Tj = +2°C

3.66

2.53

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

16.70 kW

16.65 kW

COP Tj = +7°C

5.78

4.11

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

7.67 kW

7.76 kW

COP Tj = 12°C

8.52

6.65

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

16.70 kW

16.65 kW

COP Tj = Tbiv

5.78

4.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

26.00 kW

26.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.66

2.53

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5287.00 kWh

7025.00 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

126 %

Prated

25.0 kW

25.0 kW

SCOP

3.95

3.23

Tbiv

-15.00 °C

-15.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

14.98 kW

15.14 kW

COP Tj = -7°C

3.40

2.64

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

9.42 kW

9.28 kW

COP Tj = +2°C

4.55

3.83

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

6.49 kW

6.28 kW

COP Tj = +7°C

7.03

5.14

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

6.95 kW

6.63 kW

COP Tj = 12°C

7.64

6.95

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.54 kW

20.50 kW

COP Tj = Tbiv

2.63

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.82 kW

17.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.71

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.19 kW

7.39 kW

Annual energy consumption Qhe

15592.00 kWh

19078.00 kWh

Pdh Tj = -15°C (if TOL<-20°C)

19.54

20.50

COP Tj = -15°C (if TOL<-20°C)

2.63

2.09

Cdh Tj = -15 °C

0.90

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194.9 %

150.7 %

Prated

26.0 kW

26.0 kW

SCOP

4.95

3.84

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

23.41 kW

23.26 kW

COP Tj = -7°C

3.03

2.33

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

14.36 kW

13.92 kW

COP Tj = +2°C

4.87

3.68

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

9.15 kW

9.49 kW

COP Tj = +7°C

6.80

5.51

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

6.87 kW

6.60 kW

COP Tj = 12°C

9.23

6.25

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

23.41 kW

23.26 kW

COP Tj = Tbiv

3.03

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

26.00 kW

26.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

1.98

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

10856 kWh

13984 kWh

AURUM300YMT
Configure model
Model name
AURUM300YMT
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30.00 kW

30.00 kW

El input

6.67 kW

9.57 kW

COP

4.50

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

74 dB(A)

74 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247.50 %

193.10 %

Prated

30.00 kW

30.00 kW

SCOP

6.26

4.90

Tbiv

7.00 °C

7.00 °C

TOL

2.00 °C

2.00 °C

Pdh Tj = +2°C

30.00 kW

29.76 kW

COP Tj = +2°C

3.19

2.44

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

19.09 kW

19.05 kW

COP Tj = +7°C

5.44

4.03

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

8.99 kW

9.14 kW

COP Tj = 12°C

8.42

6.70

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.09 kW

19.05 kW

COP Tj = Tbiv

5.44

4.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

30.00 kW

29.76 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.19

2.44

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.24 kW

Annual energy consumption Qhe

6399.00 kWh

8177.00 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

74 dB(A)

74 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

123 %

Prated

28.0 kW

28.0 kW

SCOP

3.91

3.14

Tbiv

-7.00 °C

-7.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

15.88 kW

16.54 kW

COP Tj = -7°C

3.56

2.50

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

10.76 kW

10.71 kW

COP Tj = +2°C

4.57

3.76

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

6.07 kW

6.69 kW

COP Tj = +7°C

6.40

5.52

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

6.92 kW

6.84 kW

COP Tj = 12°C

7.11

6.75

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

15.88 kW

16.54 kW

COP Tj = Tbiv

3.56

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.43 kW

19.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.13

1.70

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.57 kW

8.05 kW

Annual energy consumption Qhe

17664.00 kWh

21950.00 kWh

Pdh Tj = -15°C (if TOL<-20°C)

21.33

22.00

COP Tj = -15°C (if TOL<-20°C)

2.56

2.07

Cdh Tj = -15 °C

0.90

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

74 dB(A)

74 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193.8 %

148.7 %

Prated

30.0 kW

30.0 kW

SCOP

4.92

3.79

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

26.39 kW

27.36 kW

COP Tj = -7°C

2.72

2.07

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

16.65 kW

16.52 kW

COP Tj = +2°C

4.97

3.72

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

10.27 kW

10.74 kW

COP Tj = +7°C

6.91

5.55

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

7.26 kW

6.49 kW

COP Tj = 12°C

9.66

7.09

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

26.39 kW

27.36 kW

COP Tj = Tbiv

2.72

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

30.00 kW

30.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.45

1.89

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

12600 kWh

16346 kWh

AURUM350YMT
Configure model
Model name
AURUM350YMT
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

35.00 kW

35.00 kW

El input

8.40 kW

11.75 kW

COP

4.17

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240.30 %

187.10 %

Prated

35.00 kW

35.00 kW

SCOP

6.08

4.75

Tbiv

7.00 °C

7.00 °C

TOL

2.00 °C

2.00 °C

Pdh Tj = +2°C

33.92 kW

33.06 kW

COP Tj = +2°C

2.56

2.31

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

22.44 kW

22.45 kW

COP Tj = +7°C

5.42

3.98

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

10.36 kW

10.16 kW

COP Tj = 12°C

8.43

6.62

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

22.44 kW

22.45 kW

COP Tj = Tbiv

5.42

3.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

33.92 kW

33.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

2.31

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.08 kW

1.94 kW

Annual energy consumption Qhe

7687.00 kWh

9838.00 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

118 %

Prated

34.0 kW

33.5 kW

SCOP

3.85

3.03

Tbiv

-7.00 °C

-7.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

18.56 kW

18.34 kW

COP Tj = -7°C

3.49

2.33

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

11.32 kW

11.80 kW

COP Tj = +2°C

4.62

3.71

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

7.57 kW

8.16 kW

COP Tj = +7°C

6.57

5.49

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

6.92 kW

6.84 kW

COP Tj = 12°C

7.11

6.75

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

18.56 kW

18.34 kW

COP Tj = Tbiv

3.49

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.96 kW

24.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.93

1.60

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

11.04 kW

9.16 kW

Annual energy consumption Qhe

21760.00 kWh

27265.00 kWh

Pdh Tj = -15°C (if TOL<-20°C)

26.02

26.50

COP Tj = -15°C (if TOL<-20°C)

2.29

1.90

Cdh Tj = -15 °C

0.90

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176.3 %

142.4 %

Prated

35.0 kW

35.0 kW

SCOP

4.48

3.63

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

27.90 kW

30.66 kW

COP Tj = -7°C

2.55

1.93

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

18.47 kW

19.29 kW

COP Tj = +2°C

4.39

3.54

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

12.06 kW

12.50 kW

COP Tj = +7°C

6.99

5.47

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

7.59 kW

6.51 kW

COP Tj = 12°C

10.89

7.28

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

27.90 kW

30.66 kW

COP Tj = Tbiv

2.55

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

35.00 kW

34.53 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.05

1.79

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.47 kW

Annual energy consumption Qhe

16131 kWh

19899 kWh

MHC-V40WD2RN7
Configure model
Model name
MHC-V40WD2RN7
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

39.00 kW

39.00 kW

El input

9.75 kW

14.00 kW

COP

4.00

2.79

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

76 dB(A)

76 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210.80 %

177.10 %

Prated

39.00 kW

39.00 kW

SCOP

5.35

4.50

Tbiv

7.00 °C

7.00 °C

TOL

2.00 °C

2.00 °C

Pdh Tj = +2°C

33.03 kW

32.88 kW

COP Tj = +2°C

2.44

2.15

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

24.06 kW

22.84 kW

COP Tj = +7°C

4.60

3.94

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

10.40 kW

10.91 kW

COP Tj = 12°C

8.32

6.37

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

24.06 kW

22.84 kW

COP Tj = Tbiv

4.60

3.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

33.03 kW

32.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

2.15

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.98 kW

6.12 kW

Annual energy consumption Qhe

9746.00 kWh

11573.00 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

76 dB(A)

76 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

117 %

Prated

34.0 kW

33.5 kW

SCOP

3.84

3.00

Tbiv

-7.00 °C

-7.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

19.57 kW

19.91 kW

COP Tj = -7°C

3.14

2.43

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

12.29 kW

11.47 kW

COP Tj = +2°C

4.82

3.61

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

8.24 kW

8.08 kW

COP Tj = +7°C

7.02

5.29

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

6.49 kW

5.96 kW

COP Tj = 12°C

8.23

6.50

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.57 kW

19.91 kW

COP Tj = Tbiv

3.14

2.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.95 kW

23.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.54

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

11.05 kW

10.31 kW

Annual energy consumption Qhe

21823.00 kWh

27514.00 kWh

Pdh Tj = -15°C (if TOL<-20°C)

26.69

26.18

COP Tj = -15°C (if TOL<-20°C)

2.31

1.83

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

76 dB(A)

76 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165.1 %

132.5 %

Prated

39.0 kW

39.0 kW

SCOP

4.20

3.39

Tbiv

-5 °C

-5 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

31.37 kW

32.08 kW

COP Tj = -7°C

2.53

1.83

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

20.72 kW

19.72 kW

COP Tj = +2°C

4.17

3.34

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

12.92 kW

14.11 kW

COP Tj = +7°C

6.56

5.25

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

6.53 kW

6.18 kW

COP Tj = 12°C

9.22

6.67

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

31.49 kW

32.25 kW

COP Tj = Tbiv

2.62

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

34.53 kW

33.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.98

1.77

WTOL

85.00 °C

85.00 °C

Poff

14.00 W

14.00 W

PTO

13.00 W

13.00 W

PSB

14.00 W

14.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.47 kW

5.22 kW

Annual energy consumption Qhe

19176 kWh

23781 kWh