Certificate holders

Subtype

WLW376 - 30/32

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
ICIM-PDC-000401
Certification Body
ICIM S.p.A.
Subtype title
WLW376 - 30/32
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

4,900 kg

Certification Date
04.05.2026
Testing basis
n/a
Testing laboratory
IMQ S.p.A., IT
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

WLW376-30; WLW376-30 IP; WLW376-30 V; WLW376-30 IPC
Configure model
Model name
WLW376-30; WLW376-30 IP; WLW376-30 V; WLW376-30 IPC
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

40.10 kW

37.00 kW

El input

10.23 kW

13.65 kW

COP

3.92

2.71

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

139 %

Prated

29.05 kW

27.02 kW

SCOP

4.51

3.54

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

25.70 kW

23.90 kW

COP Tj = -7°C

2.67

1.95

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

15.60 kW

14.90 kW

COP Tj = +2°C

4.56

3.55

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

12.30 kW

11.60 kW

COP Tj = +7°C

6.23

5.03

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

13.80 kW

13.20 kW

COP Tj = 12°C

7.43

6.60

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

25.70 kW

23.90 kW

COP Tj = Tbiv

2.67

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.80 kW

24.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.06

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

35 °C

55 °C

Poff

110 W

110 W

PTO

180 W

180 W

PSB

110 W

110 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

3.25 kW

2.52 kW

Annual energy consumption Qhe

13341 kWh

15800 kWh

WLW376-32; WLW376-32 IP; WLW376-32 V; WLW376-32 IPC
Configure model
Model name
WLW376-32; WLW376-32 IP; WLW376-32 V; WLW376-32 IPC
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

46.80 kW

42.90 kW

El input

12.60 kW

16.70 kW

COP

3.71

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

137 %

Prated

33.69 kW

30.07 kW

SCOP

4.45

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

29.80 kW

26.60 kW

COP Tj = -7°C

2.56

1.90

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

17.70 kW

16.80 kW

COP Tj = +2°C

4.47

3.52

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

12.30 kW

11.60 kW

COP Tj = +7°C

6.23

5.03

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

13.80 kW

13.20 kW

COP Tj = 12°C

7.43

6.60

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

29.80 kW

26.60 kW

COP Tj = Tbiv

2.56

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.80 kW

24.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.06

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

35 °C

55 °C

Poff

110 W

110 W

PTO

200 W

200 W

PSB

110 W

110 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

7.89 kW

5.57 kW

Annual energy consumption Qhe

15675 kWh

17735 kWh