Certificate holders

Subtype

ADAPT 2 L

Certificate Holder
KRONOTERM d.o.o.
Trnava 5e
3303 Gomilsko
Slovenia
Registration number
011-1W1252
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ADAPT 2 L
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

2,500 kg

Certification Date
22.05.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland Energy GmbH, DE
Generate PDF Export model CSV
  • Number of models 1

Models

ADAPT 2 L / HK 3F
Configure model
Model name
ADAPT 2 L / HK 3F
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.38 kW

18.52 kW

El input

3.82 kW

5.44 kW

COP

4.81

3.40

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

8.12 kW

4.62 kW

Cooling capacity

18.56

18.49

EER

2.29

4.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

14.50 kW

14.50 kW

SEER

5.07

6.95

Pdc Tj = 35°C

14.28 kW

13.84 kW

EER Tj = 35°C

2.89

4.57

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

10.61 kW

10.69 kW

EER Tj = 30°C

4.19

5.86

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

6.82 kW

6.50 kW

EER Tj = 25°C

5.62

7.53

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

4.66 kW

6.35 kW

EER Tj = 20°C

6.57

8.62

Cdc Tj = 20 °C

0.990

0.990

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

8 W

8 W

Annual energy consumption Qce

1750 kWh

1284 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

38 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

301 %

210 %

Prated

15.50 kW

15.90 kW

SCOP

7.62

5.33

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

15.19 kW

15.24 kW

COP Tj = +2°C

3.78

2.79

Cdh Tj = +2 °C

0.999

0.999

Pdh Tj = +7°C

9.50 kW

9.66 kW

COP Tj = +7°C

6.78

4.49

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

5.90 kW

5.39 kW

COP Tj = 12°C

9.43

6.88

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

15.19 kW

15.24 kW

COP Tj = Tbiv

3.78

2.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.19 kW

15.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.78

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.999

0.999

WTOL

75 °C

75 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

6 W

6 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2727 kWh

3997 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

38 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

214 %

158 %

Prated

16.00 kW

16.00 kW

SCOP

5.43

4.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.02 kW

9.04 kW

COP Tj = -7°C

4.34

3.23

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

5.90 kW

5.83 kW

COP Tj = +2°C

7.02

5.01

Cdh Tj = +2 °C

0.993

0.995

Pdh Tj = +7°C

5.37 kW

5.01 kW

COP Tj = +7°C

8.49

6.66

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

5.99 kW

5.63 kW

COP Tj = 12°C

9.88

7.92

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

13.04 kW

13.06 kW

COP Tj = Tbiv

2.93

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.84 kW

13.14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.999

0.999

WTOL

75 °C

75 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

6 W

6 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.16 kW

2.94 kW

Annual energy consumption Qhe

7270 kWh

9782 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.04

13.06

COP Tj = -15°C (if TOL<-20°C)

2.93

2.27

Cdh Tj = -15 °C

0.999

0.999

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

38 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

175 %

Prated

14.50 kW

14.50 kW

SCOP

6.22

4.45

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.63 kW

12.11 kW

COP Tj = -7°C

3.73

2.66

Cdh Tj = -7 °C

0.998

0.999

Pdh Tj = +2°C

7.13 kW

7.32 kW

COP Tj = +2°C

6.26

4.37

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

5.42 kW

4.95 kW

COP Tj = +7°C

7.93

5.73

Cdh Tj = +7 °C

0.991

0.993

Pdh Tj = 12°C

5.92 kW

5.51 kW

COP Tj = 12°C

9.25

7.72

Cdh Tj = +12 °C

0.991

0.992

Pdh Tj = Tbiv

13.98 kW

13.82 kW

COP Tj = Tbiv

3.15

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.98 kW

13.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.999

WTOL

75 °C

75 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

6 W

6 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4819 kWh

6733 kWh