Certificate holders

Subtype

Helox SE 14

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
047-A1019 / 1
Certification Body
UL International Italia S.r.l.
Subtype title
Helox SE 14
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,600 kg

Certification Date
27.02.2025
Testing basis
Heat Pump Keymark scheme rules V15
Testing laboratory
Centro de Ensayos, Innovación y Servicios (CEIS), ES
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Helox SE 14 1P
Configure model
Model name
Helox SE 14 1P
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.05 kW

15.40 kW

El input

3.73 kW

5.27 kW

COP

4.30

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

156 %

Prated

13.50 kW

12.50 kW

SCOP

5.15

3.97

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

10.54 kW

COP Tj = -7°C

2.92

2.14

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.04 kW

7.27 kW

COP Tj = +2°C

5.26

3.83

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.36 kW

4.67 kW

COP Tj = +7°C

7.21

5.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.87 kW

3.86 kW

COP Tj = 12°C

10.43

8.47

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.15 kW

10.54 kW

COP Tj = Tbiv

2.92

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.62 kW

9.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.88 kW

2.58 kW

Annual energy consumption Qhe

5421 kWh

6507 kWh

Helox SE 14 3P
Configure model
Model name
Helox SE 14 3P
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.05 kW

15.40 kW

El input

3.73 kW

5.27 kW

COP

4.30

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

156 %

Prated

13.50 kW

12.50 kW

SCOP

5.15

3.97

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

10.54 kW

COP Tj = -7°C

2.92

2.14

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.04 kW

7.27 kW

COP Tj = +2°C

5.26

3.83

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.36 kW

4.67 kW

COP Tj = +7°C

7.21

5.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.87 kW

3.86 kW

COP Tj = 12°C

10.43

8.47

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.15 kW

10.54 kW

COP Tj = Tbiv

2.92

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.62 kW

9.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.88 kW

2.58 kW

Annual energy consumption Qhe

5421 kWh

6507 kWh