1,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.43 kW
14.00 kW
El input
2.76 kW
4.45 kW
COP
4.87
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
161 %
Prated
15.65 kW
14.43 kW
SCOP
5.29
4.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.52 kW
14.58 kW
COP Tj = -7°C
2.91
2.40
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
8.98 kW
8.56 kW
COP Tj = +2°C
5.43
4.05
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
5.85 kW
5.86 kW
COP Tj = +7°C
6.75
5.46
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
7.21 kW
6.69 kW
COP Tj = 12°C
9.05
7.23
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
15.65 kW
14.43 kW
COP Tj = Tbiv
2.62
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.65 kW
14.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.62
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
20 W
20 W
PTO
33 W
33 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6111 kWh
7270 kWh