Certificate holders

Subtype

KIRO air / water 20K heat pump

Certificate Holder
GECO GROUPE SAS
15 rue Nicolas Cugnot
F-67410 DRUSENHEIM
France
Registration number
011-1W1156
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
KIRO air / water 20K heat pump
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,900 kg

Certification Date
03.03.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 1

Models

Outdoor unit air to water KIRO20T and Indoor unit air to water KIRO20T
Configure model
Model name
Outdoor unit air to water KIRO20T and Indoor unit air to water KIRO20T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.43 kW

14.00 kW

El input

2.76 kW

4.45 kW

COP

4.87

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

209 %

161 %

Prated

15.65 kW

14.43 kW

SCOP

5.29

4.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.52 kW

14.58 kW

COP Tj = -7°C

2.91

2.40

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.98 kW

8.56 kW

COP Tj = +2°C

5.43

4.05

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.85 kW

5.86 kW

COP Tj = +7°C

6.75

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

7.21 kW

6.69 kW

COP Tj = 12°C

9.05

7.23

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

15.65 kW

14.43 kW

COP Tj = Tbiv

2.62

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.65 kW

14.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

20 W

20 W

PTO

33 W

33 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6111 kWh

7270 kWh