Certificate holders

Subtype

Packaged with water tank 8kW

Certificate Holder
GD Shenling environmental systems Co., Ltd
Xinglong 10th Rd
528313 Foshan
China
Registration number
011-1W1209
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Packaged with water tank 8kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,800 kg

Certification Date
16.02.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
Intertek Testing Services Shenzhen LTD. Guangzhou Branch, CN
Generate PDF Export model CSV
  • Number of models 1

Models

HPM-V80W/R3-D + HM-80/DR3-D
Configure model
Model name
HPM-V80W/R3-D + HM-80/DR3-D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.11 kW

7.07 kW

El input

1.74 kW

2.29 kW

COP

4.66

3.09

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

138 %

Prated

8.03 kW

7.00 kW

SCOP

4.76

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.20 kW

6.29 kW

COP Tj = -7°C

2.93

2.17

Cdh Tj = -7 °C

0.996

0.996

Pdh Tj = +2°C

4.31 kW

3.77 kW

COP Tj = +2°C

4.54

3.41

Cdh Tj = +2 °C

0.988

0.990

Pdh Tj = +7°C

4.23 kW

3.93 kW

COP Tj = +7°C

6.61

4.72

Cdh Tj = +7 °C

0.983

0.987

Pdh Tj = 12°C

4.81 kW

4.52 kW

COP Tj = 12°C

8.57

6.13

Cdh Tj = +12 °C

0.980

0.985

Pdh Tj = Tbiv

7.20 kW

6.29 kW

COP Tj = Tbiv

2.93

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.95 kW

5.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.10 kW

1.10 kW

Annual energy consumption Qhe

3482 kWh

4107 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

85 %

COP

1.97

Heating up time

1:44 h:min

Standby power input

78.0 W

Reference hot water temperature

43.7 °C

Mixed water at 40°C

127 l