Certificate holders

Subtype

Buderus WSW186i.2-13/17

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W1201
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus WSW186i.2-13/17
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R290
Mass of Refrigerant

1,000 kg

Certification Date
09.02.2026
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
RISE Research Institutes of Sweden
Generate PDF Export model CSV
  • Number of models 4

Models

WSW186i.2-13
Configure model
Model name
WSW186i.2-13
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.79 kW

11.6 kW

El input

2.97 kW

3.95 kW

COP

4.3

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

146 %

Prated

13.00 kW

12.00 kW

SCOP

5.02

3.86

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.79 kW

11.56 kW

COP Tj = +2°C

4.3

2.92

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

8.24 kW

7.81 kW

COP Tj = +7°C

4.92

3.62

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

4.81 kW

4.72 kW

COP Tj = 12°C

5.61

4.52

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

12.79 kW

11.60 kW

COP Tj = Tbiv

4.3

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13 kW

11.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.49

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0 kW

Annual energy consumption Qhe

3350 kWh

3906 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

157 %

Prated

13.00 kW

12.00 kW

SCOP

5.29

4.11

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.31 kW

7.32 kW

COP Tj = -7°C

5.11

3.83

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.85 kW

4.77 kW

COP Tj = +2°C

5.68

4.52

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.84 kW

4.74 kW

COP Tj = +7°C

5.79

4.66

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.81 kW

4.78 kW

COP Tj = 12°C

5.55

4.86

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

12.79 kW

11.6 kW

COP Tj = Tbiv

4.3

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13 kW

11.6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.49

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0 kW

Annual energy consumption Qhe

6029 kWh

7132 kWh

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201 %

150 %

Prated

13 kW

12 kW

SCOP

5.21

3.94

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.26 kW

9.73 kW

COP Tj = -7°C

4.38

3.1

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.63 kW

7.41 kW

COP Tj = +2°C

5.44

4.05

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.85 kW

4.71 kW

COP Tj = +7°C

5.68

4.45

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

4.84 kW

4.78 kW

COP Tj = 12°C

5.71

4.76

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

12.79 kW

11.6 kW

COP Tj = Tbiv

4.3

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.79 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.20

3.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

4822 kWh

5842 kWh

WSW186i.2-13 T180
Configure model
Model name
WSW186i.2-13 T180
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.79 kW

11.6 kW

El input

2.97 kW

3.95 kW

COP

4.3

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

146 %

Prated

13.00 kW

12.00 kW

SCOP

5.02

3.86

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.79 kW

11.56 kW

COP Tj = +2°C

4.3

2.92

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

8.24 kW

7.81 kW

COP Tj = +7°C

4.92

3.62

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

4.81 kW

4.72 kW

COP Tj = 12°C

5.61

4.52

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

12.79 kW

11.60 kW

COP Tj = Tbiv

4.3

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13 kW

11.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.49

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0 kW

Annual energy consumption Qhe

3350 kWh

3906 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

157 %

Prated

13.00 kW

12.00 kW

SCOP

5.29

4.11

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.31 kW

7.32 kW

COP Tj = -7°C

5.11

3.83

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.85 kW

4.77 kW

COP Tj = +2°C

5.68

4.52

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.84 kW

4.74 kW

COP Tj = +7°C

5.79

4.66

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.81 kW

4.78 kW

COP Tj = 12°C

5.55

4.86

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

12.79 kW

11.6 kW

COP Tj = Tbiv

4.3

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13 kW

11.6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.49

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0 kW

Annual energy consumption Qhe

6029 kWh

7132 kWh

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201 %

150 %

Prated

13 kW

12 kW

SCOP

5.21

3.94

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.26 kW

9.73 kW

COP Tj = -7°C

4.38

3.1

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.63 kW

7.41 kW

COP Tj = +2°C

5.44

4.05

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.85 kW

4.71 kW

COP Tj = +7°C

5.68

4.45

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

4.84 kW

4.78 kW

COP Tj = 12°C

5.71

4.76

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

12.79 kW

11.6 kW

COP Tj = Tbiv

4.3

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.79 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.20

3.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

4822 kWh

5842 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.77

Heating up time

2:09 h:min

Standby power input

39 W

Reference hot water temperature

61.1 °C

Mixed water at 40°C

301 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.77

Heating up time

2:09 h:min

Standby power input

39 W

Reference hot water temperature

61.1 °C

Mixed water at 40°C

301 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.77

Heating up time

2:09 h:min

Standby power input

39 W

Reference hot water temperature

61.1 °C

Mixed water at 40°C

301 l

WSW186i.2-17
Configure model
Model name
WSW186i.2-17
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.75 kW

14.86 kW

El input

4.15 kW

5.05 kW

COP

4.04

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

150 %

Prated

17.00 kW

15.00 kW

SCOP

5.08

3.96

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.75 kW

14.86 kW

COP Tj = +2°C

4.04

2.94

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.81 kW

9.81 kW

COP Tj = +7°C

4.75

3.52

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

4.86 kW

4.8 kW

COP Tj = 12°C

5.84

4.8

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

16.75 kW

14.86 kW

COP Tj = Tbiv

4.04

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.9 kW

14.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.11

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0 kW

Annual energy consumption Qhe

4346 kWh

5039 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

17.00 kW

15.00 kW

SCOP

5.26

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

10.53 kW

9.4 kW

COP Tj = -7°C

4.9

3.72

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.08 kW

5.96 kW

COP Tj = +2°C

5.76

4.57

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.84 kW

4.81 kW

COP Tj = +7°C

5.88

4.96

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.82 kW

4.78 kW

COP Tj = 12°C

5.63

4.91

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

16.75 kW

14.86 kW

COP Tj = Tbiv

4.04

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17 kW

14.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.11

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0 kW

Annual energy consumption Qhe

7940 kWh

8976 kWh

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

152 %

Prated

17 kW

15 kW

SCOP

5.01

3.99

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.86 kW

13.83 kW

COP Tj = -7°C

4.31

3.13

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

9.71 kW

8.01 kW

COP Tj = +2°C

4.92

3.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

6.08 kW

5.63 kW

COP Tj = +7°C

5.76

4.7

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

4.85 kW

4.79 kW

COP Tj = 12°C

5.78

4.82

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

16.75 kW

14.86 kW

COP Tj = Tbiv

4.04

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.75 kW

14.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.97

3.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

6671 kWh

7920 kWh

WSW186i.2-17 T180
Configure model
Model name
WSW186i.2-17 T180
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.75 kW

14.86 kW

El input

4.15 kW

5.05 kW

COP

4.04

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

150 %

Prated

17.00 kW

15.00 kW

SCOP

5.08

3.96

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.75 kW

14.86 kW

COP Tj = +2°C

4.04

2.94

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.81 kW

9.81 kW

COP Tj = +7°C

4.75

3.52

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

4.86 kW

4.8 kW

COP Tj = 12°C

5.84

4.8

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

16.75 kW

14.86 kW

COP Tj = Tbiv

4.04

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.9 kW

14.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.11

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0 kW

Annual energy consumption Qhe

4346 kWh

5039 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

17.00 kW

15.00 kW

SCOP

5.26

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

10.53 kW

9.4 kW

COP Tj = -7°C

4.9

3.72

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.08 kW

5.96 kW

COP Tj = +2°C

5.76

4.57

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.84 kW

4.81 kW

COP Tj = +7°C

5.88

4.96

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.82 kW

4.78 kW

COP Tj = 12°C

5.63

4.91

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

16.75 kW

14.86 kW

COP Tj = Tbiv

4.04

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17 kW

14.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.11

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0 kW

Annual energy consumption Qhe

7940 kWh

8976 kWh

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

152 %

Prated

17 kW

15 kW

SCOP

5.01

3.99

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.86 kW

13.83 kW

COP Tj = -7°C

4.31

3.13

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

9.71 kW

8.01 kW

COP Tj = +2°C

4.92

3.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

6.08 kW

5.63 kW

COP Tj = +7°C

5.76

4.7

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

4.85 kW

4.79 kW

COP Tj = 12°C

5.78

4.82

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

16.75 kW

14.86 kW

COP Tj = Tbiv

4.04

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.75 kW

14.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.97

3.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

75 °C

75 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

6671 kWh

7920 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.09

Heating up time

1:51 h:min

Standby power input

39 W

Reference hot water temperature

60.9 °C

Mixed water at 40°C

301 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.09

Heating up time

1:51 h:min

Standby power input

39 W

Reference hot water temperature

60.9 °C

Mixed water at 40°C

301 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.09

Heating up time

1:51 h:min

Standby power input

39 W

Reference hot water temperature

60.9 °C

Mixed water at 40°C

301 l