9,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
69.91 kW
65.05 kW
El input
16.52 kW
23.41 kW
COP
4.23
2.78
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
78 dB(A)
78 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
154 %
Prated
69.88 kW
65.09 kW
SCOP
4.89
3.93
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
61.82 kW
57.58 kW
COP Tj = -7°C
2.98
2.14
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
38.15 kW
35.48 kW
COP Tj = +2°C
4.85
3.97
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
24.40 kW
24.64 kW
COP Tj = +7°C
6.09
5.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
24.17 kW
22.44 kW
COP Tj = 12°C
9.17
7.09
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
61.82 kW
57.58 kW
COP Tj = Tbiv
2.98
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
69.80 kW
65.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
80 °C
80 °C
Poff
29 W
29 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.08 kW
0.00 kW
Annual energy consumption Qhe
29533 kWh
34202 kWh