3,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
31.03 kW
30.04 kW
El input
7.18 kW
10.77 kW
COP
4.32
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
70 dB(A)
70 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
142 %
Prated
31.32 kW
30.43 kW
SCOP
4.75
3.63
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
27.70 kW
26.92 kW
COP Tj = -7°C
3.10
2.32
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
16.91 kW
16.64 kW
COP Tj = +2°C
4.51
3.48
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
12.01 kW
10.84 kW
COP Tj = +7°C
6.27
4.63
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
11.80 kW
11.34 kW
COP Tj = 12°C
8.88
7.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
27.70 kW
26.92 kW
COP Tj = Tbiv
3.10
2.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
31.31 kW
30.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.09 kW
Annual energy consumption Qhe
13627 kWh
17308 kWh