Certificate holders

Subtype

Auriga-P 12/16

Certificate Holder
BAXI S.p.A.
Via Trozzetti, 20
Bassano del Grappa (VI)
Italy
Registration number
ICIM-PDC-000325 / 01
Certification Body
ICIM S.p.A.
Subtype title
Auriga-P 12/16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,250 kg

Certification Date
08.09.2023
Testing basis
V12
Testing laboratory
Bureau Veritas Consumer Products Services (Guangzhou) Co., Ltd, Science City Branch
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Auriga-P 12M
Configure model
Model name
Auriga-P 12M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.5 kW

11.5 kW

El input

2.37 kW

3.65 kW

COP

4.85

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187.8 %

147.1 %

Prated

12.1 kW

12.1 kW

SCOP

4.77

3.75

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.68 kW

10.88 kW

COP Tj = -7°C

2.8

2.27

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.69 kW

6.56 kW

COP Tj = +2°C

4.55

3.63

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.3 kW

4.78 kW

COP Tj = +7°C

6.98

4.99

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.34 kW

5.83 kW

COP Tj = 12°C

7.7

6.55

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

10.68 kW

10.88 kW

COP Tj = Tbiv

2.8

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.66 kW

10.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

WTOL

75 °C

75 °C

Poff

10.1 W

10.1 W

PTO

15 W

15 W

PSB

10.1 W

10.1 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.44 kW

1.39 kW

Annual energy consumption Qhe

5240 kWh

6662 kWh

Auriga-P 12T
Configure model
Model name
Auriga-P 12T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.5 kW

11.5 kW

El input

2.37 kW

3.65 kW

COP

4.85

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187.8 %

147.1 %

Prated

12.1 kW

12.1 kW

SCOP

4.77

3.75

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.68 kW

10.88 kW

COP Tj = -7°C

2.8

2.27

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.69 kW

6.56 kW

COP Tj = +2°C

4.55

3.63

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.3 kW

4.78 kW

COP Tj = +7°C

6.98

4.99

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.34 kW

5.83 kW

COP Tj = 12°C

7.7

6.55

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

10.68 kW

10.88 kW

COP Tj = Tbiv

2.8

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.66 kW

10.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

WTOL

75 °C

75 °C

Poff

10.1 W

10.1 W

PTO

15 W

15 W

PSB

10.1 W

10.1 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.44 kW

1.39 kW

Annual energy consumption Qhe

5240 kWh

6662 kWh

Auriga-P 16M
Configure model
Model name
Auriga-P 16M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.60 kW

15.00 kW

El input

3.63 kW

5.26 kW

COP

4.30

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

139 %

Prated

14.7 kW

14.4 kW

SCOP

4.59

3.57

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.04 kW

12.78 kW

COP Tj = -7°C

2.54

2.05

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8 kW

7.96 kW

COP Tj = +2°C

4.4

3.44

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.26 kW

4.78 kW

COP Tj = +7°C

7.12

5.13

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.28 kW

5.72 kW

COP Tj = 12°C

7.56

6.58

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.04 kW

12.78 kW

COP Tj = Tbiv

2.54

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.81 kW

12.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.94

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.89 kW

1.86 kW

Annual energy consumption Qhe

6617 kWh

8349 kWh

Auriga-P 16T
Configure model
Model name
Auriga-P 16T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.60 kW

15.00 kW

El input

3.63 kW

5.26 kW

COP

4.30

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

139 %

Prated

14.7 kW

14.4 kW

SCOP

4.59

3.57

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.04 kW

12.78 kW

COP Tj = -7°C

2.54

2.05

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8 kW

7.96 kW

COP Tj = +2°C

4.4

3.44

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.26 kW

4.78 kW

COP Tj = +7°C

7.12

5.13

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

5.28 kW

5.72 kW

COP Tj = 12°C

7.56

6.58

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.04 kW

12.78 kW

COP Tj = Tbiv

2.54

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.81 kW

12.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.94

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.89 kW

1.86 kW

Annual energy consumption Qhe

6617 kWh

8349 kWh