Certificate holders

Subtype

JAMA Star-16 inverter

Certificate Holder
Kaukora
Tuotekatu 11
FI-21200 Raisio
Finland
Registration number
012-SC0666-18
Certification Body
RISE CERT
Subtype title
JAMA Star-16 inverter
Driving energy
n/a
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R407c
Mass of Refrigerant

2,200 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Star-16 inverter
Configure model
Model name
Star-16 inverter
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.89 kW

8.54 kW

El input

1.83 kW

2.72 kW

COP

4.85

3.14

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

159 %

Prated

16.00 kW

16.00 kW

SCOP

5.48

4.18

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.80 kW

9.80 kW

COP Tj = -7°C

5.10

3.80

Pdh Tj = +2°C

6.00 kW

6.00 kW

COP Tj = +2°C

6.10

4.70

Pdh Tj = +7°C

5.70 kW

5.60 kW

COP Tj = +7°C

6.10

5.00

Pdh Tj = 12°C

5.70 kW

5.60 kW

COP Tj = 12°C

5.60

5.00

Pdh Tj = Tbiv

15.90 kW

16.00 kW

COP Tj = Tbiv

3.90

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.90

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

7 W

7 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

7218 kWh

9434 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

154 %

Prated

16.00 kW

16.00 kW

SCOP

5.18

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.20 kW

COP Tj = -7°C

4.19

3.00

Pdh Tj = +2°C

8.70 kW

8.70 kW

COP Tj = +2°C

5.26

4.10

Pdh Tj = +7°C

5.70 kW

5.60 kW

COP Tj = +7°C

6.06

4.90

Pdh Tj = 12°C

5.80 kW

5.50 kW

COP Tj = 12°C

5.85

5.00

Pdh Tj = Tbiv

15.90 kW

16.00 kW

COP Tj = Tbiv

3.90

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.90

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

7 W

7 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

6373 kWh

8167 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

10.90 kW

El input

1.84 kW

2.79 kW

COP

6.11

3.91

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

265 %

202 %

Prated

19.00 kW

19.00 kW

SCOP

6.82

5.25

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

11.60 kW

11.60 kW

COP Tj = -7°C

6.51

4.82

Pdh Tj = +2°C

7.30 kW

7.10 kW

COP Tj = +2°C

7.56

5.87

Pdh Tj = +7°C

7.30 kW

7.00 kW

COP Tj = +7°C

7.62

6.24

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.46

6.47

Pdh Tj = Tbiv

19.00 kW

19.00 kW

COP Tj = Tbiv

5.01

3.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.00 kW

19.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.01

3.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.98

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

45 W

35 W

PSB

10 W

7 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6861 kWh

8907 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

265 %

202 %

Prated

19.00 kW

19.00 kW

SCOP

6.47

5.00

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.90 kW

16.90 kW

COP Tj = -7°C

5.34

3.82

Pdh Tj = +2°C

10.30 kW

10.30 kW

COP Tj = +2°C

6.61

5.08

Pdh Tj = +7°C

7.20 kW

7.00 kW

COP Tj = +7°C

7.50

5.93

Pdh Tj = 12°C

7.30 kW

7.10 kW

COP Tj = 12°C

7.61

6.28

Pdh Tj = Tbiv

19.00 kW

19.00 kW

COP Tj = Tbiv

5.01

3.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.00 kW

19.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.01

3.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.97

0.98

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

45 W

35 W

PSB

10 W

7 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6070 kWh

7834 kWh

Star-16 RST inverter
Configure model
Model name
Star-16 RST inverter
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.89 kW

8.54 kW

El input

1.83 kW

2.72 kW

COP

4.85

3.14

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

159 %

Prated

16.00 kW

16.00 kW

SCOP

5.48

4.18

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.80 kW

9.80 kW

COP Tj = -7°C

5.10

3.80

Pdh Tj = +2°C

6.00 kW

6.00 kW

COP Tj = +2°C

6.10

4.70

Pdh Tj = +7°C

5.70 kW

5.60 kW

COP Tj = +7°C

6.10

5.00

Pdh Tj = 12°C

5.70 kW

5.60 kW

COP Tj = 12°C

5.60

5.00

Pdh Tj = Tbiv

15.90 kW

16.00 kW

COP Tj = Tbiv

3.90

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.90

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

7 W

7 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

7218 kWh

9434 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

154 %

Prated

16.00 kW

16.00 kW

SCOP

5.18

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.20 kW

COP Tj = -7°C

4.19

3.00

Pdh Tj = +2°C

8.70 kW

8.70 kW

COP Tj = +2°C

5.26

4.10

Pdh Tj = +7°C

5.70 kW

5.60 kW

COP Tj = +7°C

6.06

4.90

Pdh Tj = 12°C

5.80 kW

5.50 kW

COP Tj = 12°C

5.85

5.00

Pdh Tj = Tbiv

15.90 kW

16.00 kW

COP Tj = Tbiv

3.90

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.90

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

7 W

7 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

6373 kWh

8167 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.45

Heating up time

01:04 h:min

Standby power input

50.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

240 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.45

Heating up time

01:04 h:min

Standby power input

50.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

240 l

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

10.90 kW

El input

1.84 kW

2.79 kW

COP

6.11

3.91

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

265 %

202 %

Prated

19.00 kW

19.00 kW

SCOP

6.82

5.25

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

11.60 kW

11.60 kW

COP Tj = -7°C

6.51

4.82

Pdh Tj = +2°C

7.30 kW

7.10 kW

COP Tj = +2°C

7.56

5.87

Pdh Tj = +7°C

7.30 kW

7.00 kW

COP Tj = +7°C

7.62

6.24

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.46

6.47

Pdh Tj = Tbiv

19.00 kW

19.00 kW

COP Tj = Tbiv

5.01

3.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.00 kW

19.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.01

3.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.98

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

45 W

35 W

PSB

10 W

7 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6861 kWh

8907 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

265 %

202 %

Prated

19.00 kW

19.00 kW

SCOP

6.47

5.00

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.90 kW

16.90 kW

COP Tj = -7°C

5.34

3.82

Pdh Tj = +2°C

10.30 kW

10.30 kW

COP Tj = +2°C

6.61

5.08

Pdh Tj = +7°C

7.20 kW

7.00 kW

COP Tj = +7°C

7.50

5.93

Pdh Tj = 12°C

7.30 kW

7.10 kW

COP Tj = 12°C

7.61

6.28

Pdh Tj = Tbiv

19.00 kW

19.00 kW

COP Tj = Tbiv

5.01

3.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.00 kW

19.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.01

3.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.97

0.98

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

45 W

35 W

PSB

10 W

7 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6070 kWh

7834 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.82

Heating up time

00:58 h:min

Standby power input

45.0 W

Reference hot water temperature

45.0 °C

Mixed water at 40°C

235 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.82

Heating up time

00:58 h:min

Standby power input

45.0 W

Reference hot water temperature

45.0 °C

Mixed water at 40°C

235 l