Certificate holders

Subtype

iTec E 8 400V

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
011-1W1045
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
iTec E 8 400V
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,150 kg

Certification Date
22.04.2025
Testing basis
European KEYMARK Scheme for Heat Pumps rev.15
Generate PDF Export model CSV
  • Number of models 1

Models

iTec E 8 400V
Configure model
Model name
iTec E 8 400V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.10 kW

El input

1.77 kW

2.53 kW

COP

4.52

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

126 %

Prated

8.00 kW

8.00 kW

SCOP

4.44

3.23

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

2.63

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.31 kW

4.31 kW

COP Tj = +2°C

4.24

3.11

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.10 kW

2.80 kW

COP Tj = +7°C

6.39

4.55

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.60 kW

2.40 kW

COP Tj = 12°C

8.22

5.77

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

2.63

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.66

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.20 kW

Annual energy consumption Qhe

3719 kWh

5113 kWh