Certificate holders

Subtype

iTec E 5 230-1

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
011-1W1044
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
iTec E 5 230-1
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,000 kg

Certification Date
22.04.2025
Testing basis
HP KEYMARK certification scheme rules V15
Generate PDF Export model CSV
  • Number of models 1

Models

iTec E 5 230-1
Configure model
Model name
iTec E 5 230-1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

4.30 kW

El input

1.03 kW

1.52 kW

COP

4.85

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

125 %

Prated

6.00 kW

5.00 kW

SCOP

4.46

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.87 kW

4.42 kW

COP Tj = -7°C

2.99

2.16

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.96 kW

2.69 kW

COP Tj = +2°C

4.18

3.17

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.90 kW

1.73 kW

COP Tj = +7°C

6.11

4.03

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.88 kW

1.70 kW

COP Tj = 12°C

7.70

4.73

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.87 kW

4.42 kW

COP Tj = Tbiv

2.99

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.59 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

0.80 kW

Annual energy consumption Qhe

2548 kWh

3224 kWh