Certificate holders

Subtype

Solax thermal ST series 8 10kW

Certificate Holder
SolaX Power Network Technology (Zhejiang) Co., Ltd.
No.278, Shizhu Road, Chengnan Sub-district
311599 Tonglu County, Hangzhou, Zhejiang China
China
Registration number
011-1W1110
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Solax thermal ST series 8 10kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,200 kg

Certification Date
17.10.2025
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 12

Models

Indoor unit STN1-C03(9W3) and outdoor unit STU1-C08R290
Configure model
Model name
Indoor unit STN1-C03(9W3) and outdoor unit STU1-C08R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.00 kW

El input

1.65 kW

2.32 kW

COP

5.15

3.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

162 %

Prated

8.00 kW

8.00 kW

SCOP

5.44

4.12

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.40

2.54

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.42 kW

4.43 kW

COP Tj = +2°C

5.37

4.09

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.55 kW

3.49 kW

COP Tj = +7°C

6.97

5.22

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.25 kW

4.15 kW

COP Tj = 12°C

8.27

6.47

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.40

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.91 kW

7.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.13 kW

Annual energy consumption Qhe

3036 kWh

4009 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:15 h:min

Standby power input

38.0 W

Reference hot water temperature

46.5 °C

Mixed water at 40°C

169 l

Indoor unit STN3-C03(9W3) and outdoor unit STU3-C08R290
Configure model
Model name
Indoor unit STN3-C03(9W3) and outdoor unit STU3-C08R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.00 kW

El input

1.65 kW

2.32 kW

COP

5.15

3.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

162 %

Prated

8.00 kW

8.00 kW

SCOP

5.44

4.12

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.40

2.54

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.42 kW

4.43 kW

COP Tj = +2°C

5.37

4.09

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.55 kW

3.49 kW

COP Tj = +7°C

6.97

5.22

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.25 kW

4.15 kW

COP Tj = 12°C

8.27

6.47

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.40

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.91 kW

7.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.13 kW

Annual energy consumption Qhe

3036 kWh

4009 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:15 h:min

Standby power input

38.0 W

Reference hot water temperature

46.5 °C

Mixed water at 40°C

169 l

Indoor unit STN1-C01 and outdoor unit STU1-C08R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU1-C08R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.00 kW

El input

1.65 kW

2.32 kW

COP

5.15

3.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

162 %

Prated

8.00 kW

8.00 kW

SCOP

5.44

4.12

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.40

2.54

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.42 kW

4.43 kW

COP Tj = +2°C

5.37

4.09

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.55 kW

3.49 kW

COP Tj = +7°C

6.97

5.22

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.25 kW

4.15 kW

COP Tj = 12°C

8.27

6.47

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.40

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.91 kW

7.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.13 kW

Annual energy consumption Qhe

3036 kWh

4009 kWh

Indoor unit STN1-C01 and outdoor unit STU3-C08R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU3-C08R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.00 kW

El input

1.65 kW

2.32 kW

COP

5.15

3.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

162 %

Prated

8.00 kW

8.00 kW

SCOP

5.44

4.12

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.40

2.54

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.42 kW

4.43 kW

COP Tj = +2°C

5.37

4.09

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.55 kW

3.49 kW

COP Tj = +7°C

6.97

5.22

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.25 kW

4.15 kW

COP Tj = 12°C

8.27

6.47

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.40

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.91 kW

7.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.13 kW

Annual energy consumption Qhe

3036 kWh

4009 kWh

Indoor unit STN1-C02(9) and outdoor unit STU1-C08R290
Configure model
Model name
Indoor unit STN1-C02(9) and outdoor unit STU1-C08R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.00 kW

El input

1.65 kW

2.32 kW

COP

5.15

3.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

162 %

Prated

8.00 kW

8.00 kW

SCOP

5.44

4.12

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.40

2.54

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.42 kW

4.43 kW

COP Tj = +2°C

5.37

4.09

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.55 kW

3.49 kW

COP Tj = +7°C

6.97

5.22

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.25 kW

4.15 kW

COP Tj = 12°C

8.27

6.47

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.40

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.91 kW

7.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.13 kW

Annual energy consumption Qhe

3036 kWh

4009 kWh

Indoor unit STN3-C02(9) and outdoor unit STU3-C08R290
Configure model
Model name
Indoor unit STN3-C02(9) and outdoor unit STU3-C08R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.00 kW

El input

1.65 kW

2.32 kW

COP

5.15

3.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

162 %

Prated

8.00 kW

8.00 kW

SCOP

5.44

4.12

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.40

2.54

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.42 kW

4.43 kW

COP Tj = +2°C

5.37

4.09

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

3.55 kW

3.49 kW

COP Tj = +7°C

6.97

5.22

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.25 kW

4.15 kW

COP Tj = 12°C

8.27

6.47

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.40

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.91 kW

7.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.13 kW

Annual energy consumption Qhe

3036 kWh

4009 kWh

Indoor unit STN1-C03(9W3) and outdoor unit STU1-C10R290
Configure model
Model name
Indoor unit STN1-C03(9W3) and outdoor unit STU1-C10R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.02 kW

3.08 kW

COP

4.95

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

209 %

160 %

Prated

10.00 kW

10.00 kW

SCOP

5.30

4.07

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.85 kW

8.85 kW

COP Tj = -7°C

3.03

2.31

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.58 kW

5.46 kW

COP Tj = +2°C

5.18

4.04

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.60 kW

3.52 kW

COP Tj = +7°C

7.41

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.27 kW

4.17 kW

COP Tj = 12°C

8.88

6.75

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

8.85 kW

8.85 kW

COP Tj = Tbiv

3.03

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

8.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.43 kW

Annual energy consumption Qhe

3899 kWh

5080 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:15 h:min

Standby power input

38.0 W

Reference hot water temperature

46.5 °C

Mixed water at 40°C

169 l

Indoor unit STN3-C03(9W3) and outdoor unit STU3-C10R290
Configure model
Model name
Indoor unit STN3-C03(9W3) and outdoor unit STU3-C10R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.02 kW

3.08 kW

COP

4.95

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

209 %

160 %

Prated

10.00 kW

10.00 kW

SCOP

5.30

4.07

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.85 kW

8.85 kW

COP Tj = -7°C

3.03

2.31

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.58 kW

5.46 kW

COP Tj = +2°C

5.18

4.04

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.60 kW

3.52 kW

COP Tj = +7°C

7.41

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.27 kW

4.17 kW

COP Tj = 12°C

8.88

6.75

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

8.85 kW

8.85 kW

COP Tj = Tbiv

3.03

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

8.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.43 kW

Annual energy consumption Qhe

3899 kWh

5080 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:15 h:min

Standby power input

38.0 W

Reference hot water temperature

46.5 °C

Mixed water at 40°C

169 l

Indoor unit STN1-C01 and outdoor unit STU1-C10R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU1-C10R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.02 kW

3.08 kW

COP

4.95

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

209 %

160 %

Prated

10.00 kW

10.00 kW

SCOP

5.30

4.07

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.85 kW

8.85 kW

COP Tj = -7°C

3.03

2.31

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.58 kW

5.46 kW

COP Tj = +2°C

5.18

4.04

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.60 kW

3.52 kW

COP Tj = +7°C

7.41

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.27 kW

4.17 kW

COP Tj = 12°C

8.88

6.75

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

8.85 kW

8.85 kW

COP Tj = Tbiv

3.03

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

8.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.43 kW

Annual energy consumption Qhe

3899 kWh

5080 kWh

Indoor unit STN1-C01 and outdoor unit STU3-C10R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU3-C10R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.02 kW

3.08 kW

COP

4.95

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

209 %

160 %

Prated

10.00 kW

10.00 kW

SCOP

5.30

4.07

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.85 kW

8.85 kW

COP Tj = -7°C

3.03

2.31

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.58 kW

5.46 kW

COP Tj = +2°C

5.18

4.04

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.60 kW

3.52 kW

COP Tj = +7°C

7.41

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.27 kW

4.17 kW

COP Tj = 12°C

8.88

6.75

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

8.85 kW

8.85 kW

COP Tj = Tbiv

3.03

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

8.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.43 kW

Annual energy consumption Qhe

3899 kWh

5080 kWh

Indoor unit STN1-C02(9) and outdoor unit STU1-C10R290
Configure model
Model name
Indoor unit STN1-C02(9) and outdoor unit STU1-C10R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.02 kW

3.08 kW

COP

4.95

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

209 %

160 %

Prated

10.00 kW

10.00 kW

SCOP

5.30

4.07

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.85 kW

8.85 kW

COP Tj = -7°C

3.03

2.31

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.58 kW

5.46 kW

COP Tj = +2°C

5.18

4.04

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.60 kW

3.52 kW

COP Tj = +7°C

7.41

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.27 kW

4.17 kW

COP Tj = 12°C

8.88

6.75

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

8.85 kW

8.85 kW

COP Tj = Tbiv

3.03

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

8.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.43 kW

Annual energy consumption Qhe

3899 kWh

5080 kWh

Indoor unit STN3-C02(9) and outdoor unit STU3-C10R290
Configure model
Model name
Indoor unit STN3-C02(9) and outdoor unit STU3-C10R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.02 kW

3.08 kW

COP

4.95

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

209 %

160 %

Prated

10.00 kW

10.00 kW

SCOP

5.30

4.07

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.85 kW

8.85 kW

COP Tj = -7°C

3.03

2.31

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.58 kW

5.46 kW

COP Tj = +2°C

5.18

4.04

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

3.60 kW

3.52 kW

COP Tj = +7°C

7.41

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

4.27 kW

4.17 kW

COP Tj = 12°C

8.88

6.75

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

8.85 kW

8.85 kW

COP Tj = Tbiv

3.03

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

8.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

13 W

13 W

PTO

21 W

21 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.43 kW

Annual energy consumption Qhe

3899 kWh

5080 kWh