Certificate holders

Subtype

Solax thermal ST series 12 14 16kW

Certificate Holder
SolaX Power Network Technology (Zhejiang) Co., Ltd.
No.278, Shizhu Road, Chengnan Sub-district
311599 Tonglu County, Hangzhou, Zhejiang China
China
Registration number
011-1W1111
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Solax thermal ST series 12 14 16kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,500 kg

Certification Date
17.10.2025
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 18

Models

Indoor unit STN1-C03(9W3) and outdoor unit STU1-C12R290
Configure model
Model name
Indoor unit STN1-C03(9W3) and outdoor unit STU1-C12R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.50 kW

12.00 kW

El input

2.55 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

12.00 kW

12.00 kW

SCOP

5.09

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.61 kW

COP Tj = -7°C

3.05

2.35

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.55 kW

6.49 kW

COP Tj = +2°C

4.87

3.76

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.51 kW

5.18 kW

COP Tj = +7°C

6.96

5.25

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.06 kW

COP Tj = 12°C

7.98

6.25

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.62 kW

10.61 kW

COP Tj = Tbiv

3.05

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.85 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.15 kW

Annual energy consumption Qhe

4902 kWh

6373 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.85

Heating up time

00:51 h:min

Standby power input

41.0 W

Reference hot water temperature

46.8 °C

Mixed water at 40°C

172 l

Indoor unit STN3-C03(9W3) and outdoor unit STU3-C12R290
Configure model
Model name
Indoor unit STN3-C03(9W3) and outdoor unit STU3-C12R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.50 kW

12.00 kW

El input

2.55 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

12.00 kW

12.00 kW

SCOP

5.09

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.61 kW

COP Tj = -7°C

3.05

2.35

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.55 kW

6.49 kW

COP Tj = +2°C

4.87

3.76

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.51 kW

5.18 kW

COP Tj = +7°C

6.96

5.25

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.06 kW

COP Tj = 12°C

7.98

6.25

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.62 kW

10.61 kW

COP Tj = Tbiv

3.05

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.85 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.15 kW

Annual energy consumption Qhe

4902 kWh

6373 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.85

Heating up time

00:51 h:min

Standby power input

41.0 W

Reference hot water temperature

46.8 °C

Mixed water at 40°C

172 l

Indoor unit STN1-C01 and outdoor unit STU1-C12R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU1-C12R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.50 kW

12.00 kW

El input

2.55 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

12.00 kW

12.00 kW

SCOP

5.09

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.61 kW

COP Tj = -7°C

3.05

2.35

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.55 kW

6.49 kW

COP Tj = +2°C

4.87

3.76

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.51 kW

5.18 kW

COP Tj = +7°C

6.96

5.25

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.06 kW

COP Tj = 12°C

7.98

6.25

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.62 kW

10.61 kW

COP Tj = Tbiv

3.05

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.85 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.15 kW

Annual energy consumption Qhe

4902 kWh

6373 kWh

Indoor unit STN1-C01 and outdoor unit STU3-C12R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU3-C12R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.50 kW

12.00 kW

El input

2.55 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

12.00 kW

12.00 kW

SCOP

5.09

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.61 kW

COP Tj = -7°C

3.05

2.35

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.55 kW

6.49 kW

COP Tj = +2°C

4.87

3.76

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.51 kW

5.18 kW

COP Tj = +7°C

6.96

5.25

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.06 kW

COP Tj = 12°C

7.98

6.25

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.62 kW

10.61 kW

COP Tj = Tbiv

3.05

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.85 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.15 kW

Annual energy consumption Qhe

4902 kWh

6373 kWh

Indoor unit STN1-C02(9) and outdoor unit STU1-C12R290
Configure model
Model name
Indoor unit STN1-C02(9) and outdoor unit STU1-C12R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.50 kW

12.00 kW

El input

2.55 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

12.00 kW

12.00 kW

SCOP

5.09

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.61 kW

COP Tj = -7°C

3.05

2.35

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.55 kW

6.49 kW

COP Tj = +2°C

4.87

3.76

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.51 kW

5.18 kW

COP Tj = +7°C

6.96

5.25

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.06 kW

COP Tj = 12°C

7.98

6.25

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.62 kW

10.61 kW

COP Tj = Tbiv

3.05

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.85 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.15 kW

Annual energy consumption Qhe

4902 kWh

6373 kWh

Indoor unit STN3-C02(9) and outdoor unit STU3-C12R290
Configure model
Model name
Indoor unit STN3-C02(9) and outdoor unit STU3-C12R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.50 kW

12.00 kW

El input

2.55 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

12.00 kW

12.00 kW

SCOP

5.09

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.61 kW

COP Tj = -7°C

3.05

2.35

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.55 kW

6.49 kW

COP Tj = +2°C

4.87

3.76

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.51 kW

5.18 kW

COP Tj = +7°C

6.96

5.25

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.06 kW

COP Tj = 12°C

7.98

6.25

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.62 kW

10.61 kW

COP Tj = Tbiv

3.05

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.85 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.15 kW

Annual energy consumption Qhe

4902 kWh

6373 kWh

Indoor unit STN1-C03(9W3) and outdoor unit STU1-C14R290
Configure model
Model name
Indoor unit STN1-C03(9W3) and outdoor unit STU1-C14R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.95 kW

4.44 kW

COP

4.75

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

14.00 kW

14.00 kW

SCOP

4.94

3.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.39 kW

12.39 kW

COP Tj = -7°C

2.88

2.20

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.58 kW

7.57 kW

COP Tj = +2°C

4.67

3.70

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.55 kW

5.30 kW

COP Tj = +7°C

7.25

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.09 kW

COP Tj = 12°C

8.19

6.39

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

12.39 kW

12.39 kW

COP Tj = Tbiv

2.88

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.93 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.42

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

1.10 kW

Annual energy consumption Qhe

5852 kWh

7530 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.85

Heating up time

00:51 h:min

Standby power input

41.0 W

Reference hot water temperature

46.8 °C

Mixed water at 40°C

172 l

Indoor unit STN3-C03(9W3) and outdoor unit STU3-C14R290
Configure model
Model name
Indoor unit STN3-C03(9W3) and outdoor unit STU3-C14R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.95 kW

4.44 kW

COP

4.75

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

14.00 kW

14.00 kW

SCOP

4.94

3.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.39 kW

12.39 kW

COP Tj = -7°C

2.88

2.20

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.58 kW

7.57 kW

COP Tj = +2°C

4.67

3.70

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.55 kW

5.30 kW

COP Tj = +7°C

7.25

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.09 kW

COP Tj = 12°C

8.19

6.39

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

12.39 kW

12.39 kW

COP Tj = Tbiv

2.88

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.93 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.42

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

1.10 kW

Annual energy consumption Qhe

5852 kWh

7530 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.85

Heating up time

00:51 h:min

Standby power input

41.0 W

Reference hot water temperature

46.8 °C

Mixed water at 40°C

172 l

Indoor unit STN1-C01 and outdoor unit STU1-C14R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU1-C14R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.95 kW

4.44 kW

COP

4.75

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

14.00 kW

14.00 kW

SCOP

4.94

3.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.39 kW

12.39 kW

COP Tj = -7°C

2.88

2.20

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.58 kW

7.57 kW

COP Tj = +2°C

4.67

3.70

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.55 kW

5.30 kW

COP Tj = +7°C

7.25

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.09 kW

COP Tj = 12°C

8.19

6.39

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

12.39 kW

12.39 kW

COP Tj = Tbiv

2.88

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.93 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.42

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

1.10 kW

Annual energy consumption Qhe

5852 kWh

7530 kWh

Indoor unit STN1-C01 and outdoor unit STU3-C14R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU3-C14R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.95 kW

4.44 kW

COP

4.75

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

14.00 kW

14.00 kW

SCOP

4.94

3.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.39 kW

12.39 kW

COP Tj = -7°C

2.88

2.20

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.58 kW

7.57 kW

COP Tj = +2°C

4.67

3.70

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.55 kW

5.30 kW

COP Tj = +7°C

7.25

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.09 kW

COP Tj = 12°C

8.19

6.39

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

12.39 kW

12.39 kW

COP Tj = Tbiv

2.88

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.93 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.42

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

1.10 kW

Annual energy consumption Qhe

5852 kWh

7530 kWh

Indoor unit STN1-C02(9) and outdoor unit STU1-C14R290
Configure model
Model name
Indoor unit STN1-C02(9) and outdoor unit STU1-C14R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.95 kW

4.44 kW

COP

4.75

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

14.00 kW

14.00 kW

SCOP

4.94

3.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.39 kW

12.39 kW

COP Tj = -7°C

2.88

2.20

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.58 kW

7.57 kW

COP Tj = +2°C

4.67

3.70

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.55 kW

5.30 kW

COP Tj = +7°C

7.25

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.09 kW

COP Tj = 12°C

8.19

6.39

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

12.39 kW

12.39 kW

COP Tj = Tbiv

2.88

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.93 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.42

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

1.10 kW

Annual energy consumption Qhe

5852 kWh

7530 kWh

Indoor unit STN3-C02(9) and outdoor unit STU3-C14R290
Configure model
Model name
Indoor unit STN3-C02(9) and outdoor unit STU3-C14R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.95 kW

4.44 kW

COP

4.75

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

14.00 kW

14.00 kW

SCOP

4.94

3.84

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.39 kW

12.39 kW

COP Tj = -7°C

2.88

2.20

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

7.58 kW

7.57 kW

COP Tj = +2°C

4.67

3.70

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

5.55 kW

5.30 kW

COP Tj = +7°C

7.25

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.27 kW

6.09 kW

COP Tj = 12°C

8.19

6.39

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

12.39 kW

12.39 kW

COP Tj = Tbiv

2.88

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.93 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.42

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

1.10 kW

Annual energy consumption Qhe

5852 kWh

7530 kWh

Indoor unit STN1-C03(9W3) and outdoor unit STU1-C16R290
Configure model
Model name
Indoor unit STN1-C03(9W3) and outdoor unit STU1-C16R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.50 kW

16.00 kW

El input

3.41 kW

5.16 kW

COP

4.55

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

150 %

Prated

16.00 kW

14.86 kW

SCOP

4.90

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.15 kW

13.15 kW

COP Tj = -7°C

2.69

2.18

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.55 kW

7.98 kW

COP Tj = +2°C

4.68

3.69

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.55 kW

5.21 kW

COP Tj = +7°C

7.39

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.30 kW

6.11 kW

COP Tj = 12°C

8.42

6.48

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

14.15 kW

13.15 kW

COP Tj = Tbiv

2.69

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.03 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

1.96 kW

Annual energy consumption Qhe

6749 kWh

8016 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.85

Heating up time

00:51 h:min

Standby power input

41.0 W

Reference hot water temperature

46.8 °C

Mixed water at 40°C

172 l

Indoor unit STN3-C03(9W3) and outdoor unit STU3-C16R290
Configure model
Model name
Indoor unit STN3-C03(9W3) and outdoor unit STU3-C16R290
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.50 kW

16.00 kW

El input

3.41 kW

5.16 kW

COP

4.55

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

150 %

Prated

16.00 kW

14.86 kW

SCOP

4.90

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.15 kW

13.15 kW

COP Tj = -7°C

2.69

2.18

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.55 kW

7.98 kW

COP Tj = +2°C

4.68

3.69

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.55 kW

5.21 kW

COP Tj = +7°C

7.39

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.30 kW

6.11 kW

COP Tj = 12°C

8.42

6.48

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

14.15 kW

13.15 kW

COP Tj = Tbiv

2.69

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.03 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

1.96 kW

Annual energy consumption Qhe

6749 kWh

8016 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.85

Heating up time

00:51 h:min

Standby power input

41.0 W

Reference hot water temperature

46.8 °C

Mixed water at 40°C

172 l

Indoor unit STN1-C01 and outdoor unit STU1-C16R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU1-C16R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.50 kW

16.00 kW

El input

3.41 kW

5.16 kW

COP

4.55

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

150 %

Prated

16.00 kW

14.86 kW

SCOP

4.90

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.15 kW

13.15 kW

COP Tj = -7°C

2.69

2.18

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.55 kW

7.98 kW

COP Tj = +2°C

4.68

3.69

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.55 kW

5.21 kW

COP Tj = +7°C

7.39

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.30 kW

6.11 kW

COP Tj = 12°C

8.42

6.48

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

14.15 kW

13.15 kW

COP Tj = Tbiv

2.69

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.03 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

1.96 kW

Annual energy consumption Qhe

6749 kWh

8016 kWh

Indoor unit STN1-C01 and outdoor unit STU3-C16R290
Configure model
Model name
Indoor unit STN1-C01 and outdoor unit STU3-C16R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.50 kW

16.00 kW

El input

3.41 kW

5.16 kW

COP

4.55

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

30 dB(A)

30 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

150 %

Prated

16.00 kW

14.86 kW

SCOP

4.90

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.15 kW

13.15 kW

COP Tj = -7°C

2.69

2.18

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.55 kW

7.98 kW

COP Tj = +2°C

4.68

3.69

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.55 kW

5.21 kW

COP Tj = +7°C

7.39

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.30 kW

6.11 kW

COP Tj = 12°C

8.42

6.48

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

14.15 kW

13.15 kW

COP Tj = Tbiv

2.69

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.03 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

1.96 kW

Annual energy consumption Qhe

6749 kWh

8016 kWh

Indoor unit STN1-C02(9) and outdoor unit STU1-C16R290
Configure model
Model name
Indoor unit STN1-C02(9) and outdoor unit STU1-C16R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.50 kW

16.00 kW

El input

3.41 kW

5.16 kW

COP

4.55

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

150 %

Prated

16.00 kW

14.86 kW

SCOP

4.90

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.15 kW

13.15 kW

COP Tj = -7°C

2.69

2.18

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.55 kW

7.98 kW

COP Tj = +2°C

4.68

3.69

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.55 kW

5.21 kW

COP Tj = +7°C

7.39

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.30 kW

6.11 kW

COP Tj = 12°C

8.42

6.48

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

14.15 kW

13.15 kW

COP Tj = Tbiv

2.69

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.03 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

1.96 kW

Annual energy consumption Qhe

6749 kWh

8016 kWh

Indoor unit STN3-C02(9) and outdoor unit STU3-C16R290
Configure model
Model name
Indoor unit STN3-C02(9) and outdoor unit STU3-C16R290
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.50 kW

16.00 kW

El input

3.41 kW

5.16 kW

COP

4.55

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

150 %

Prated

16.00 kW

14.86 kW

SCOP

4.90

3.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.15 kW

13.15 kW

COP Tj = -7°C

2.69

2.18

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.55 kW

7.98 kW

COP Tj = +2°C

4.68

3.69

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.55 kW

5.21 kW

COP Tj = +7°C

7.39

5.46

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

6.30 kW

6.11 kW

COP Tj = 12°C

8.42

6.48

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

14.15 kW

13.15 kW

COP Tj = Tbiv

2.69

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.03 kW

12.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

80 °C

80 °C

Poff

17 W

17 W

PTO

31 W

31 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

1.96 kW

Annual energy consumption Qhe

6749 kWh

8016 kWh