Certificate holders

Subtype

Jäspi Inverter Nordic 20

Certificate Holder
Kaukora
Tuotekatu 11
FI-21200 Raisio
Finland
Registration number
012-SC0656-18
Certification Body
RISE CERT
Subtype title
Jäspi Inverter Nordic 20
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,000 kg

Certification Date
05.05.2020
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Jäspi Inverter Nordic 20
Configure model
Model name
Jäspi Inverter Nordic 20
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.94 kW

7.25 kW

El input

1.43 kW

2.35 kW

COP

4.85

3.08

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

134 %

Prated

13.00 kW

14.00 kW

SCOP

4.19

3.41

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.90 kW

8.50 kW

COP Tj = -7°C

3.50

2.85

Pdh Tj = +2°C

6.20 kW

6.10 kW

COP Tj = +2°C

5.25

4.15

Pdh Tj = +7°C

5.90 kW

6.00 kW

COP Tj = +7°C

5.60

4.80

Pdh Tj = 12°C

6.70 kW

6.40 kW

COP Tj = 12°C

7.00

5.80

Pdh Tj = Tbiv

9.60 kW

10.30 kW

COP Tj = Tbiv

3.15

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.30 kW

8.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

7 W

7 W

PSB

25 W

25 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.70 kW

5.30 kW

Annual energy consumption Qhe

7639 kWh

10108 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

11.00 kW

12.30 kW

SCOP

5.05

3.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.70 kW

10.90 kW

COP Tj = -7°C

3.41

2.48

Pdh Tj = +2°C

6.50 kW

6.70 kW

COP Tj = +2°C

5.08

3.96

Pdh Tj = +7°C

6.90 kW

5.90 kW

COP Tj = +7°C

5.95

4.69

Pdh Tj = 12°C

6.80 kW

6.50 kW

COP Tj = 12°C

7.36

5.81

Pdh Tj = Tbiv

9.70 kW

10.90 kW

COP Tj = Tbiv

3.41

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.11

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

7 W

7 W

PSB

25 W

25 W

PCK

37 W

37 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.20 kW

0.70 kW

Annual energy consumption Qhe

4508 kWh

6530 kWh